Literature DB >> 18561638

6 MV dosimetric characterization of the 160 MLC, the new Siemens multileaf collimator.

Martin B Tacke1, Simeon Nill, Peter Häring, Uwe Oelfke.   

Abstract

New technical developments constantly aim at improving the outcome of radiation therapy. With the use of a computer-controlled multileaf collimator (MLC), the quality of the treatment and the efficiency in patient throughput is significantly increased. New MLC designs aim to further enhance the advantages. In this article, we present the first detailed experimental investigation of the new 160 MLC, Siemens Medical Solutions. The assessment included the experimental investigation of typical MLC characteristics such as leakage, tongue-and-groove effect, penumbra, leaf speed, and leaf positioning accuracy with a 6 MV treatment beam. The leakage is remarkably low with an average of 0.37% due to a new design principle of slightly tilted leaves instead of the common tongue-and-groove design. But due to the tilt, the triangular tongue-and-groove effect occurs. Its magnitude of approximately 19% is similar to the dose defect measured for MLCs with the common tongue-and-groove design. The average longitudinal penumbra measured at depth d(max) = 15 mm with standard 100 x 100 mm2 fields is 4.1 +/- 0.5 mm for the central range and increases to 4.9 +/- 1.3 mm for the entire field range of 400 x 400 mm2. The increase is partly due to the single-focusing design and the large distance between the MLC and the isocenter enabling a large patient clearance. Regarding the leaf speed, different velocity tests were performed. The positions of the moving leaves were continuously recorded with the kilovoltage-imaging panel. The maximum leaf velocities measured were 42.9 +/- 0.6 mm/s. In addition, several typical intensity-modulated radiation therapy treatments were performed and the delivery times compared to the Siemens OPTIFOCUS MLC. An average decrease of 11% in delivery time was observed. The experimental results presented in this article indicate that the dosimetric characteristics of the 160 MLC are capable of improving the quality of dose delivery with respect to precision and dose conformity.

Entities:  

Mesh:

Year:  2008        PMID: 18561638     DOI: 10.1118/1.2889782

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  The impact of direct aperture optimization on plan quality and efficiency in complex head and neck IMRT.

Authors:  Marcello Sabatino; Matthias Kretschmer; Klemens Zink; Florian Würschmidt
Journal:  Radiat Oncol       Date:  2012-01-23       Impact factor: 3.481

2.  Monte Carlo Modeling of the Agility MLC for IMRT and VMAT Calculations.

Authors:  Shingo Ohira; Hideki Takegawa; Masayoshi Miyazaki; Masahiko Koizumi; Teruki Teshima
Journal:  In Vivo       Date:  2020 Sep-Oct       Impact factor: 2.155

3.  Analytical model for out-of-field dose in photon craniospinal irradiation.

Authors:  Phillip J Taddei; Wassim Jalbout; Rebecca M Howell; Nabil Khater; Fady Geara; Kenneth Homann; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2013-10-08       Impact factor: 3.609

4.  Dosimetric impact of different multileaf collimators on prostate intensity modulated treatment planning.

Authors:  Lucia Clara Orlandini; Margherita Betti; Christian Fulcheri; Marianna Coppola; Luca Cionini
Journal:  Rep Pract Oncol Radiother       Date:  2015-09-29

5.  Planning for mARC treatments with the Eclipse treatment planning system.

Authors:  Vikren Sarkar; Long Huang; Prema Rassiah-Szegedi; Hui Zhao; Jessica Huang; Martin Szegedi; Bill J Salter
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

6.  Development and performance evaluation of a high-speed multileaf collimator.

Authors:  Xiang Zhang; Peiqing Ye; Hui Zhang
Journal:  J Appl Clin Med Phys       Date:  2016-12-29       Impact factor: 2.102

7.  The impact of flattening-filter-free beam technology on 3D conformal RT.

Authors:  Matthias Kretschmer; Marcello Sabatino; Arne Blechschmidt; Sebastian Heyden; Bernd Grünberg; Florian Würschmidt
Journal:  Radiat Oncol       Date:  2013-05-31       Impact factor: 3.481

8.  Impact of MLC properties and IMRT technique in meningioma and head-and-neck treatments.

Authors:  Steffi Kantz; Matthias Söhn; Almut Troeller; Michael Reiner; Helmut Weingandt; Markus Alber; Claus Belka; Ute Ganswindt
Journal:  Radiat Oncol       Date:  2015-09-02       Impact factor: 3.481

9.  Capability of leaf interdigitation with different inverse planning strategies in Monaco: an investigation of representative tumour sites.

Authors:  Jinghao Duan; Xiangjuan Meng; Tonghai Liu; Yong Yin
Journal:  Radiat Oncol       Date:  2016-06-17       Impact factor: 3.481

10.  Dosimetric impact of the 160 MLC on head and neck IMRT treatments.

Authors:  Prema Rassiah-Szegedi; Martin Szegedi; Vikren Sarkar; Seth Streitmatter; Y Jessica Huang; Hui Zhao; Bill Salter
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.