Literature DB >> 18560053

A multichannel portable ECG system with capacitive sensors.

M Oehler1, V Ling, K Melhorn, M Schilling.   

Abstract

Capacitive sensors can be employed for measuring the electrocardiogram of a human heart without electric contact with the skin. This configuration avoids contact problems experienced by conventional electrocardiography. In our studies, we integrated these capacitive electrocardiogram electrodes in a 15-sensor array and combined this array with a tablet personal computer. By placing the system on the patient's body, we can measure a 15-channel electrocardiogram even through clothes and without any preparation. The goal of this development is to provide a new diagnostic tool that offers the user a reproducible, easy access to a fast and spatially resolved diagnostic 'heart view'.

Entities:  

Mesh:

Year:  2008        PMID: 18560053     DOI: 10.1088/0967-3334/29/7/007

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  10 in total

1.  First clinical evaluation of a novel capacitive ECG system in patients with acute myocardial infarction.

Authors:  Mareike B Weil; Martin Oehler; Meinhard Schilling; Lars S Maier
Journal:  Clin Res Cardiol       Date:  2011-11-08       Impact factor: 5.460

2.  A Novel Antibacterial Membrane Electrode Based on Bacterial Cellulose/Polyaniline/AgNO3 Composite for Bio-Potential Signal Monitoring.

Authors:  Nannan Zhang; Lina Yue; Yajie Xie; Oluwarotimi William Samuel; Olatunji Mumini Omisore; Weihua Pei; Xiao Xing; Chuang Lin; Yudong Zheng; Lei Wang
Journal:  IEEE J Transl Eng Health Med       Date:  2018-08-06       Impact factor: 3.316

3.  Development of Novel Non-Contact Electrodes for Mobile Electrocardiogram Monitoring System.

Authors:  Bor-Shyh Lin; Willy Chou; Hsing-Yu Wang; Yan-Jun Huang; Jeng-Shyang Pan
Journal:  IEEE J Transl Eng Health Med       Date:  2013-06-04       Impact factor: 3.316

4.  In-ovo imaging using ostrich eggs: Biomagnetism for detection of cardiac signals and embryonal motion.

Authors:  Martin Freesmeyer; Hanna Hermeyer; Christian Kuehnel; Olga Perkas; Julia Greiser; Otto W Witte; Thomas Winkens
Journal:  Exp Biol Med (Maywood)       Date:  2022-04-25

5.  Evaluation of a novel portable capacitive ECG system in the clinical practice for a fast and simple ECG assessment in patients presenting with chest pain: FIDET (Fast Infarction Diagnosis ECG Trial).

Authors:  Eva C L Rasenack; Martin Oehler; Albrecht Elsässer; Meinhard Schilling; Lars S Maier
Journal:  Clin Res Cardiol       Date:  2012-09-29       Impact factor: 5.460

6.  Flexible capacitive electrodes for minimizing motion artifacts in ambulatory electrocardiograms.

Authors:  Jeong Su Lee; Jeong Heo; Won Kyu Lee; Yong Gyu Lim; Youn Ho Kim; Kwang Suk Park
Journal:  Sensors (Basel)       Date:  2014-08-12       Impact factor: 3.576

7.  Design and Development of Non-Contact Bio-Potential Electrodes for Pervasive Health Monitoring Applications.

Authors:  Anthony J Portelli; Slawomir J Nasuto
Journal:  Biosensors (Basel)       Date:  2017-01-01

8.  Noise-Resistant CECG Using Novel Capacitive Electrodes.

Authors:  Chi-Chun Chen; Cheng-Wei Chen; Chang-Wei Hsieh
Journal:  Sensors (Basel)       Date:  2020-05-01       Impact factor: 3.576

9.  Lower limb wearable capacitive sensing and its applications to recognizing human gaits.

Authors:  Enhao Zheng; Baojun Chen; Kunlin Wei; Qining Wang
Journal:  Sensors (Basel)       Date:  2013-10-01       Impact factor: 3.576

10.  Multi-Channel Capacitive Sensor Arrays.

Authors:  Bingnan Wang; Jiang Long; Koon Hoo Teo
Journal:  Sensors (Basel)       Date:  2016-01-25       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.