Literature DB >> 18545050

Fixed partial dentures and crowns supported by very small diameter dental implants in compromised sites.

Dennis Flanagan1.   

Abstract

Very small diameter (1.8-3.3 mm) dental implants may be successfully used to support fixed partial dentures in edentulous sites of compromised bone width or length. Very small implants can be successfully used in highly selected sites where there is adequate bone density and bone volume for immediate implant stability. Adequate or augmentable attached gingiva may be a requirement. A small diameter implant presents less of an obstacle for angiogenesis and there is less percutaneous exposure and bone displacement as compared with standard sized implants. In posterior sites, rounded and narrow prosthetic teeth present small occlusal tables to minimize axial and off-axial directed forces. Multiple splinted implants may be necessary to minimize metal fatigue from cyclic loading. Anterior restorations supported by mini implants may need occlusal relief to minimize the effects of cyclic loading.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18545050     DOI: 10.1097/ID.0b013e31817776cf

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  5 in total

1.  A pilot study of mini implants as a treatment option for prosthetic rehabilitation of ridges with sub-optimal bone volume.

Authors:  Anitha Balaji; Jumshad B Mohamed; R Kathiresan
Journal:  J Maxillofac Oral Surg       Date:  2011-02-25

2.  Fracture and Fatigue of Titanium Narrow Dental Implants: New Trends in Order to Improve the Mechanical Response.

Authors:  Eugenio Velasco-Ortega; Antonio Flichy-Fernández; Miquel Punset; Alvaro Jiménez-Guerra; José María Manero; Javier Gil
Journal:  Materials (Basel)       Date:  2019-11-12       Impact factor: 3.623

3.  Influence of Connection Type and Platform Diameter on Titanium Dental Implants Fatigue: Non-Axial Loading Cyclic Test Analysis.

Authors:  Ana I Nicolas-Silvente; Eugenio Velasco-Ortega; Ivan Ortiz-Garcia; Alvaro Jimenez-Guerra; Loreto Monsalve-Guil; Raul Ayuso-Montero; Javier Gil; Jose Lopez-Lopez
Journal:  Int J Environ Res Public Health       Date:  2020-12-02       Impact factor: 3.390

4.  Rehabilitation of resorbed mandibular ridges using mini implant retained overdentures: A case series with 3 year follow-up.

Authors:  Pooja Kumari; Mahesh Verma; Vikrant Sainia; Rekha Gupta; Shubhra Gill
Journal:  J Indian Prosthodont Soc       Date:  2016 Apr-Jun

5.  Peri-implant biomechanical responses to standard, short-wide, and double mini implants replacing missing molar supporting hybrid ceramic or full-metal crowns under axial and off-axial loading: an in vitro study.

Authors:  Lamiaa Said Elfadaly; Lamiaa Sayed Khairallah; Mona Atteya Al Agroudy
Journal:  Int J Implant Dent       Date:  2017-07-13
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.