Literature DB >> 18534467

Is there a place for rotating-hinge arthroplasty in knee revision surgery for aseptic loosening?

Nayana Joshi1, Antonio Navarro-Quilis.   

Abstract

We reviewed the results of 78 revision total knee arthroplasties using a rotating-hinge device, performed from 1993 through 2002. The average follow-up was 7.83 years. Only patients requiring revision arthroplasty due to aseptic loosening were included. Reasons for revision were malalignment with or without polyethylene wear (47), instability (24), extensor mechanism failure (3), and periprosthetic fracture (4). The mean preoperative scores according to the American Knee Society rating scale was 37.5 points for knee score and 32.8 points for function score. Postoperatively, the knee score improved to 85.7 points and the function score improved to 61.4 points. Nineteen patients had complications related to the design prostheses (mostly minor complications). Fifty-seven patients (73%) had excellent results, with a range of motion of 104 degrees in flexion and complete extension. For extreme circumstances, such as gross instability of the medial collateral ligament, massive bone loss, comminuted fracture, and chronic dysfunction of the extensor mechanism, there is a place for hinged revision implant surgery with good clinical results and quality of life.

Entities:  

Mesh:

Year:  2008        PMID: 18534467     DOI: 10.1016/j.arth.2007.10.016

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  33 in total

Review 1.  Surgical treatment options in patients with impaired bone quality.

Authors:  Norman A Johanson; Jody Litrenta; Jay M Zampini; Frederic Kleinbart; Haviva M Goldman
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

2.  Case report: Failure of rotating-hinge total knee prosthesis by disengagement of the hinge-post extension.

Authors:  Debdut Biswas; Bryan Haughom; Robert E Mayle; Craig J Della Valle
Journal:  Clin Orthop Relat Res       Date:  2012-12-11       Impact factor: 4.176

Review 3.  Failure rate of a rotating hinge knee design due to yoke fracture of the hinged tibial insert: a retrospective data analysis and review of the literature.

Authors:  Joerg Friesenbichler; Ran Schwarzkopf; Patrick Sadoghi; Scott E Marwin; Mathias Glehr; Werner Maurer-Ertl; Andreas Leithner
Journal:  Int Orthop       Date:  2011-12-28       Impact factor: 3.075

4.  Revision knee arthroplasty with rotating hinge systems in patients with gross ligament instability.

Authors:  Sebastian P Boelch; Joerg Arnholdt; Boris M Holzapfel; Axel Jakuscheit; Maximilian Rudert; Maik Hoberg
Journal:  Int Orthop       Date:  2018-05-22       Impact factor: 3.075

5.  A 3 year minimum follow up of Endoprosthetic replacement for distal femoral fractures - An alternative treatment option.

Authors:  A Atrey; N Hussain; O Gosling; P Giannoudis; A Shepherd; S Young; J Waite
Journal:  J Orthop       Date:  2017-01-10

6.  Hinged total knee arthroplasty in the presence of ligamentous deficiency.

Authors:  Daniel Hernández-Vaquero; Manuel A Sandoval-García
Journal:  Clin Orthop Relat Res       Date:  2010-05       Impact factor: 4.176

7.  Midterm assessment of causes and results of revision total knee arthroplasty.

Authors:  Fahad Hossain; Shelain Patel; Fares Sami Haddad
Journal:  Clin Orthop Relat Res       Date:  2010-05       Impact factor: 4.176

8.  [Pathologic fracture of the distal femur in total knee arthroplasty. Polyethylene-wear-induced osteolysis? A case report].

Authors:  M Napp; M Frank; M Witt
Journal:  Orthopade       Date:  2009-10       Impact factor: 1.087

9.  The Endo-Model(®) rotating hinge for rheumatoid knees : Functional results in primary and revision surgery.

Authors:  L Felli; M Coviello; M Alessio-Mazzola; M Cutolo
Journal:  Orthopade       Date:  2016-05       Impact factor: 1.087

10.  Revision knee arthroplasty with a rotating-hinge design in elderly patients with instability following total knee arthroplasty.

Authors:  E Carlos Rodríguez-Merchán; Primitivo Gómez-Cardero; Ángel Martínez-Lloreda
Journal:  J Clin Orthop Trauma       Date:  2014-11-20
View more