Literature DB >> 18534400

In vitro cyclic testing of the Exeter stem after cement within cement revision.

Lance Jon Wilson1, Cameron Gordon Roodveldt Bell, Patrick Weinrauch, Ross Crawford.   

Abstract

Cement-within-cement (C-C) revision arthroplasty minimizes the complications associated with removal of secure polymethylmethacrylate. Failure at the interfacial region between new and old cement mantles remains a theoretical concern. This article assesses the cyclic fatigue properties of bilaminar cement mantles after C-C revision in vitro with the Exeter stem. Seven Exeter stems were cemented into Sawbone femurs and removed, and new undersized stems were cemented into the preserved mantle. The new constructs were loaded for 1,000,000 cycles at body temperature. Cement mantles were inspected postcycling. In no case was there delamination or failure of the cement mantle. The findings support the hypothesis that use of a thin revision cement mantle in conjunction with a polished double-tapered stem is not detrimental to the overall success of the implant. In the presence of a secure cement-bone interface in suitable patients, we recommend C-C revision techniques using double-tapered polished femoral stems.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18534400     DOI: 10.1016/j.arth.2008.02.014

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  4 in total

Review 1.  Cement-in-cement technique of the femoral component in aseptic total hip arthroplasty revision: A systematic review of the contemporary literature.

Authors:  Michael-Alexander Malahias; Fabio Mancino; Amil Agarwal; Leonidas Roumeliotis; Alex Gu; Ioannis Gkiatas; Danilo Togninalli; Vasileios S Nikolaou; Michael M Alexiades
Journal:  J Orthop       Date:  2021-06-30

2.  Ultrasonic cement removal in cement-in-cement revision total hip arthroplasty: What is the effect on the final cement-in-cement bond?

Authors:  A Liddle; M Webb; N Clement; S Green; J Liddle; M German; J Holland
Journal:  Bone Joint Res       Date:  2019-07-05       Impact factor: 5.853

3.  Impact of a double-layer cementing technique on the homogeneity of cementation and the generation of loose bone cement fragments in tibial unicompartmental knee arthroplasty.

Authors:  Christian B Scheele; Matthias F Pietschmann; Christian Schröder; Christian Suren; Thomas M Grupp; Peter E Müller
Journal:  BMC Musculoskelet Disord       Date:  2019-11-13       Impact factor: 2.362

4.  The cement-bone bond is weaker than cement-cement bond in cement-in-cement revision arthroplasty. A comparative biomechanical study.

Authors:  Marcin Ceynowa; Krzysztof Zerdzicki; Pawel Klosowski; Maciej Zrodowski; Rafal Pankowski; Marek Roclawski; Tomasz Mazurek
Journal:  PLoS One       Date:  2021-02-11       Impact factor: 3.240

  4 in total