Literature DB >> 18534395

Comparison of computer-assisted navigation and conventional instrumentation for bilateral total knee arthroplasty.

Yi-Jan Weng1, Robert Wen-Wei Hsu, Wei-Hsiu Hsu.   

Abstract

This prospective study analyzed computer-assisted surgery (CAS) navigation and conventional instrumentation in bilateral total knee arthroplasty. Sixty patients underwent CAS navigation in 1 knee and conventional instrumentation in the contralateral knee randomly. The target zone resided in the reconstructed mechanical axis within a range of 3 degrees varus or valgus. The reconstructed mechanical axes in the CAS navigation group were significantly closer to planned axes than those in the conventional group. Average blood loss in the CAS navigation group was lower, whereas mean tourniquet time was longer than in the conventional group. No surgery-related complications existed in either group. The results indicate that, despite longer operative time, CAS navigation total knee arthroplasty is a safe procedure and outperforms conventional technique in accuracy of leg axes.

Entities:  

Mesh:

Year:  2008        PMID: 18534395     DOI: 10.1016/j.arth.2008.03.006

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  25 in total

1.  The limits of precision in conventionally instrumented computer-navigated total knee arthroplasty.

Authors:  R E da Assunção; N J Hancock; W J M Bruce; P Walker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-23       Impact factor: 4.342

2.  Effect of preoperative deformity on postoperative leg axis in total knee arthroplasty: a prospective randomized study.

Authors:  Wei-Hsiu Hsu; Robert Wen Wei Hsu; Yi-Jan Weng
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-04-27       Impact factor: 4.342

Review 3.  Surgical management of osteoarthritis.

Authors:  Jeffrey N Katz; Brandon E Earp; Andreas H Gomoll
Journal:  Arthritis Care Res (Hoboken)       Date:  2010-09       Impact factor: 4.794

Review 4.  Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?

Authors:  Tao Cheng; Song Zhao; Xiaochun Peng; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-06       Impact factor: 4.342

5.  Differences in component and limb alignment between computer-assisted and conventional surgery total knee arthroplasty.

Authors:  Tsan-Wen Huang; Kuo-Ti Peng; Kuo-Chin Huang; Mel S Lee; Robert Wen-Wei Hsu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-10-21       Impact factor: 4.342

Review 6.  Computer-assisted total knee arthroplasty is currently of no proven clinical benefit: a systematic review.

Authors:  R Stephen J Burnett; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

Review 7.  Hip arthroscopy: the use of computer assistance.

Authors:  Danyal H Nawabi; Denis Nam; Caroline Park; Anil S Ranawat
Journal:  HSS J       Date:  2013-01-03

8.  Do patient-specific guides improve coronal alignment in total knee arthroplasty?

Authors:  Ryan M Nunley; Bradley S Ellison; Jinjun Zhu; Erin L Ruh; Stephen M Howell; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2011-12-20       Impact factor: 4.176

9.  Can computer assistance improve the clinical and functional scores in total knee arthroplasty?

Authors:  Daniel Hernández-Vaquero; Abelardo Suarez-Vazquez; Susana Iglesias-Fernandez
Journal:  Clin Orthop Relat Res       Date:  2011-08-27       Impact factor: 4.176

10.  Comparison of long-term clinical outcomes after bilateral mobile-bearing total knee arthroplasties using PCL-retaining and PCL-substituting implants in the same patients.

Authors:  Yoshinori Ishii; Hideo Noguchi; Junko Sato; Tetsuya Sakurai; Shin-Ichi Toyabe
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-04-30       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.