Literature DB >> 18534394

Characterization of a highly cross-linked ultrahigh molecular-weight polyethylene in clinical use in total hip arthroplasty.

Michel P Laurent1, Todd S Johnson, Roy D Crowninshield, Cheryl R Blanchard, Sushil K Bhambri, Jian Q Yao.   

Abstract

This article reports on a commercially available extensively cross-linked ultrahigh molecular-weight polyethylene (HXPE) produced by subjecting molded GUR 1050 ultrahigh molecular-weight polyethylene (UHMWPE) to 100 +/- 10 kGy of electron beam radiation followed by melt annealing and sterilization by gas plasma. When compared to contemporary conventional molded GUR 1050 UHMWPE sterilized by 37 kGy of gamma radiation, the HXPE material has enhanced wear properties, has no detectable free radicals, and is resistant to oxidation and oxidative-related material property changes. The relative wear improvement of the HXPE is maintained in the presence of bone cement or alumina particles. The HXPE produced greater than 90% fewer wear particles in all size ranges and statistically significantly (P < .0001) smaller average-size particles than did the conventional UHMWPE.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18534394     DOI: 10.1016/j.arth.2007.06.006

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  8 in total

Review 1.  [Implant wear and aseptic loosening. An overview].

Authors:  C Kaddick; I Catelas; P H Pennekamp; M A Wimmer
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

Review 2.  Polyethylene and metal wear particles: characteristics and biological effects.

Authors:  Isabelle Catelas; Markus A Wimmer; Sandra Utzschneider
Journal:  Semin Immunopathol       Date:  2011-01-26       Impact factor: 9.623

3.  Natural history of squeaking after total hip arthroplasty.

Authors:  Camilo Restrepo; Wadih Y Matar; Javad Parvizi; Richard H Rothman; William J Hozack
Journal:  Clin Orthop Relat Res       Date:  2010-09       Impact factor: 4.176

4.  A novel formulation for scratch-based wear modelling in total hip arthroplasty.

Authors:  Karen M Kruger; Nishant M Tikekar; Anneliese D Heiner; Thomas E Baer; John J Lannutti; John J Callaghan; Thomas D Brown
Journal:  Comput Methods Biomech Biomed Engin       Date:  2013-01-10       Impact factor: 1.763

Review 5.  Surface Texturing of Prosthetic Hip Implant Bearing Surfaces: A Review.

Authors:  Quentin Allen; Bart Raeymaekers
Journal:  J Tribol       Date:  2020-10-05       Impact factor: 2.045

Review 6.  Wear Debris Characterization and Corresponding Biological Response: Artificial Hip and Knee Joints.

Authors:  Md J Nine; Dipankar Choudhury; Ay Ching Hee; Rajshree Mootanah; Noor Azuan Abu Osman
Journal:  Materials (Basel)       Date:  2014-02-10       Impact factor: 3.623

Review 7.  Status of surface modification techniques for artificial hip implants.

Authors:  Subir Ghosh; Sylvester Abanteriba
Journal:  Sci Technol Adv Mater       Date:  2016-11-25       Impact factor: 8.090

8.  The Effect of Texture Floor Profile on the Lubricant Film Thickness in a Textured Hard-On-Soft Bearing With Relevance to Prosthetic Hip Implants.

Authors:  Quentin Allen; Bart Raeymaekers
Journal:  J Tribol       Date:  2020-08-03       Impact factor: 2.045

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.