Indirect measurement of systemic blood pressure in conscious dogs in a clinical setting.

Tsai-Yuan Hsiang1, Yu-Hsin Lien, Hui-Pi Huang.   

Abstract

The present study compared 2 indirect methods, Doppler sphygmomanometry and oscillometry, for measurement of the systemic blood pressure level in 100 conscious, client-owned dogs in a clinical setting on 2 separate occasions. The mean systemic blood pressure values, measured by Doppler sphygmomanometry on 2 separate occasions, were 156 +/- 38.2 mmHg and 150 +/- 34.1 mmHg, respectively. Using oscillometry, the mean systolic blood pressure values were 138 +/- 36.9 mm Hg and 133 +/- 33.5 mm Hg on 2 separate occasions. There were significant differences between the systemic blood pressure readings for both methods on the same occasion (P<0.001). The coefficients of variance from 5 consecutive measurements in the same dog obtained by Doppler sphygmomanometry on the 2 separate occasions were 4.1 +/- 3.2% and 3.1 +/- 1.7%; that of the oscillometric method on the 2 separate occasions were 18.7 +/- 11.3% and 17.2 +/- 12.5%. The coefficients of variance of these 2 methods were statistically different on each occasion (P<0.001). Five consecutive systemic blood pressure readings were obtained for each dog within 6 min on both occasions using Doppler sphygmomanometry. More than 15 min was required to complete 5 consecutive systemic blood pressure readings by oscillometric sphygmomanometry for all dogs on each occasion. The results of this study indicate that Doppler sphygmomanometry provides more efficient and precise measurements of the systemic blood pressure level than oscillometric testing in conscious dogs in a clinical setting.

Entities:  

Mesh:

Year:  2008        PMID: 18525165     DOI: 10.1292/jvms.70.449

Source DB:  PubMed          Journal:  J Vet Med Sci        ISSN: 0916-7250            Impact factor:   1.267


  7 in total

1.  Oscillometric and Doppler arterial blood pressure measurement in conscious goats.

Authors:  Olga Szaluś-Jordanow; Michał Czopowicz; Anna Świerk; Oktawia Szpinda; Magdalena Garncarz; Marcin Mickiewicz; Agata Moroz; Emilia Bagnicka; Jarosław Kaba
Journal:  Can J Vet Res       Date:  2018-10       Impact factor: 1.310

2.  Associations among systemic blood pressure, microalbuminuria and albuminuria in dogs affected with pituitary- and adrenal-dependent hyperadrenocorticism.

Authors:  Yu-Hsin Lien; Tsai-Yuan Hsiang; Hui-Pi Huang
Journal:  Acta Vet Scand       Date:  2010-11-12       Impact factor: 1.695

3.  Effects of various factors on Doppler flow ultrasonic radial and coccygeal artery systolic blood pressure measurements in privately-owned, conscious dogs.

Authors:  Allison P Mooney; Dianne I Mawby; Joshua M Price; Jacqueline C Whittemore
Journal:  PeerJ       Date:  2017-03-22       Impact factor: 2.984

4.  Comparison of oscillometric, Doppler and invasive blood pressure measurement in anesthetized goats.

Authors:  Olga Szaluś-Jordanow; Michał Czopowicz; Agata Moroz; Marcin Mickiewicz; Magdalena Garncarz; Emilia Bagnicka; Tadeusz Frymus; Jarosław Kaba
Journal:  PLoS One       Date:  2018-05-23       Impact factor: 3.240

5.  Indirect Doppler flow systolic blood pressure measurements taken with and without headphones in privately-owned, conscious dogs.

Authors:  India R Gill; Joshua M Price; Jacqueline C Whittemore
Journal:  PeerJ       Date:  2019-08-01       Impact factor: 2.984

6.  Comparison between the Parks Medical Doppler and the Mano Médical Vet BP Doppler for recording indirect systemic blood pressure in conscious dogs.

Authors:  Marina Domingues; Panagiotis E Archontakis; Jonathan Bouvard; Luke Winter; Danielle A Gunn-Moore
Journal:  Open Vet J       Date:  2022-08-19

7.  Comparison of forelimb and hindlimb systolic blood pressures and proteinuria in healthy Shetland Sheepdogs.

Authors:  B A Scansen; J Vitt; D J Chew; K E Schober; J D Bonagura
Journal:  J Vet Intern Med       Date:  2014-01-16       Impact factor: 3.333

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.