Literature DB >> 18521655

Novel procedure for treatment of aortic obstruction caused by amplatzer occluder of patent ductus arteriosus.

Sadiq Al-Hamash1, Isam V Nasir.   

Abstract

An 18-month-old boy with patent ductus arteriosus and pulmonary hypertension is reported, in whom deployment of the Amplatzer ductal occluder caused significant aortic obstruction, requiring the inflation of an intraortic balloon against the aortic retention disk of the device as a new procedure to treat such an obstruction. This case emphasizes the need for careful hemodynamic and angiographic assessment of the position of the Amplatzer ductal occluder before and after detaching the device from its delivery system, with particular emphasis on the aortic retention ring and the possibility of interventional management of this complication.

Entities:  

Mesh:

Year:  2008        PMID: 18521655     DOI: 10.1007/s00246-008-9241-0

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  9 in total

1.  Transcatheter Closure of Patent Ductus Arteriosus Using the Amplatzer Duct Occluder.

Authors:  David J. Waight; Qi-Ling Cao; Ziyad M. Hijazi
Journal:  Curr Interv Cardiol Rep       Date:  2001-08

2.  Percutaneous closure of the small (less than 2.5 mm) patent ductus arteriosus using coil embolization.

Authors:  P A Cambier; W C Kirby; D C Wortham; J W Moore
Journal:  Am J Cardiol       Date:  1992-03-15       Impact factor: 2.778

3.  Catheter closure of moderate- to large-sized patent ductus arteriosus using the new Amplatzer duct occluder: immediate and short-term results.

Authors:  J Masura; K P Walsh; B Thanopoulous; C Chan; J Bass; Y Goussous; P Gavora; Z M Hijazi
Journal:  J Am Coll Cardiol       Date:  1998-03-15       Impact factor: 24.094

4.  Angiographic classification of the isolated, persistently patent ductus arteriosus and implications for percutaneous catheter occlusion.

Authors:  A Krichenko; L N Benson; P Burrows; C A Möes; P McLaughlin; R M Freedom
Journal:  Am J Cardiol       Date:  1989-04-01       Impact factor: 2.778

5.  Transcatheter closure of persistent ductus arteriosus in infants using the Amplatzer duct occluder.

Authors:  G Fischer; J Stieh; A Uebing; R Grabitz; H H Kramer
Journal:  Heart       Date:  2001-10       Impact factor: 5.994

6.  [Transcatheter closure of patent ductus arteriosus using the Amplatzer duct occluder: initial results and mid-term follow-up].

Authors:  Aurora Fernández Ruiz; M Jesús del Cerro Marín; Dolores Rubio Vidal; M Carmen Castro Gussoni; Felipe Moreno Granados
Journal:  Rev Esp Cardiol       Date:  2002-10       Impact factor: 4.753

7.  Aortic obstruction caused by device occlusion of patent arterial duct.

Authors:  C Duke; K C Chan
Journal:  Heart       Date:  1999-07       Impact factor: 5.994

8.  Transcatheter occlusion of patent ductus arteriosus with adjustable buttoned device. Initial clinical experience.

Authors:  P S Rao; E B Sideris; J Haddad; C Rey; G Hausdorf; A D Wilson; P A Smith; P S Chopra
Journal:  Circulation       Date:  1993-09       Impact factor: 29.690

9.  Nonsurgical closure of patent ductus arteriosus: clinical application of the Rashkind PDA Occluder System.

Authors:  W J Rashkind; C E Mullins; W E Hellenbrand; M A Tait
Journal:  Circulation       Date:  1987-03       Impact factor: 29.690

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.