Literature DB >> 18519219

SURF imaging: in vivo demonstration of an ultrasound contrast agent detection technique.

S E Masoy1, O Standal, P Nasholm, T F Johansen, Bjorn Angelsen, Rune Hansen.   

Abstract

A dual-band method for ultrasound contrast agent detection is demonstrated in vivo in an animal experiment using pigs. The method is named Second -order UltRasound Field Imaging, abbreviated SURF Imaging. It relies on simultaneously transmitting two ultrasound pulses with a large separation in frequency. Here, a low-frequency pulse of 0.9 MHz is combined with a high-frequency pulse of 7.5 MHz. The low-frequency pulse is used to manipulate the properties of the contrast agent, and the high frequency pulse is used for high-resolution contrast detection and imaging. An annular array capable of transmitting the low- and high-frequency pulses simultaneously was constructed and fitted to a mechanically scanned probe used in a GE Vingmed System 5 ultrasound scanner. The scanner was modified and adapted for the dual-band transmit technique. In-house software was written for post-processing of recorded IQ-data. Contrast-processed B-mode images of pig kidneys after bolus injections of 1 mL of Sonovuer are presented. The images display contrast detection with contrast-to-tissue ratios ranging from 15-40 dB. The results demonstrate the potential of SURF Imaging as an ultrasound contrast detection technique for clinically high ultrasound frequencies. This may allow ultrasound contrast imaging to be available for a wide range of applications.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18519219     DOI: 10.1109/TUFFC.2008.763

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  5 in total

Review 1.  Superharmonic Imaging for Medical Ultrasound: a Review.

Authors:  Narendra D Londhe; Jasjit S Suri
Journal:  J Med Syst       Date:  2016-10-27       Impact factor: 4.460

Review 2.  Molecular ultrasound imaging: current status and future directions.

Authors:  N Deshpande; A Needles; J K Willmann
Journal:  Clin Radiol       Date:  2010-07       Impact factor: 2.350

3.  Radial modulation contrast imaging using a 20-MHz single-element intravascular ultrasound catheter.

Authors:  Francois T H Yu; Flordeliza S Villanueva; Xucai Chen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-05       Impact factor: 2.725

4.  A Dual-Frequency Colinear Array for Acoustic Angiography in Prostate Cancer Evaluation.

Authors:  Sibo Li; Jinwook Kim; Zhuochen Wang; Sandeep Kasoji; Brooks D Lindsey; Paul A Dayton; Xiaoning Jiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-10-01       Impact factor: 2.725

Review 5.  Ultrasound contrast microbubbles in imaging and therapy: physical principles and engineering.

Authors:  Shengping Qin; Charles F Caskey; Katherine W Ferrara
Journal:  Phys Med Biol       Date:  2009-02-19       Impact factor: 3.609

  5 in total