Literature DB >> 18512017

Prospective trial evaluating new circular and linear stapler devices for gastrointestinal anastomosis: preliminary data.

P De Nardi1, F Panzeri, C Staudacher.   

Abstract

Several commercial models of stapler devices are available. This study evaluated the ease of use, effectiveness and safety of new commercial stapling devices for gastrointestinal anastomosis. A total of 11 patients (5 men) requiring surgical therapy for benign or malignant disease of the digestive tract were recruited between July and October 2006. Eleven patients were treated with KYGW circular stapler or KYFB linear stapler (Changzhou Kangdi Medical Stapler). In these patients, 14 staplers were used and 21 stapled sutures (16 linear, 5 circular) were performed. Number of anastomoses successfully completed, postoperative anastomotic fistula or dehiscence, days to take fluid and normal diet, length of hospital stay and anastomotic stenosis were recorded. A 10-point questionnaire enquiring about the instrument and anastomotic features was administered to surgeons immediately after the operation in the study group and in 10 control patients treated with standard CDH circular and SDH linear staples (Ethicon Endo-Surgery). Mean scores on the questionnaire for the experimental and control groups were good (>7.5) and did not significantly differ for handling, closing ease, bleeding, and overall satisfaction. No case of intra-abdominal sepsis, leakage or intestinal obstruction was recorded in the study group. In the 5 patients with colorectal anastomosis, the anastomotic lumen at 15 days was wide open and at 3 months there were no strictures. These new instruments are valuable for performing gastrointestinal anastomosis and are in conformity with clinical requirements; their use is simple and seems to be safe.

Entities:  

Mesh:

Year:  2008        PMID: 18512017     DOI: 10.1007/s10151-008-0401-2

Source DB:  PubMed          Journal:  Tech Coloproctol        ISSN: 1123-6337            Impact factor:   3.781


  6 in total

1.  Management of recurrent anastomotic stricture and iatrogenic stenosis by circular stapler.

Authors:  J R E Rees; L Carney; T S Gill; A R Dixon
Journal:  Dis Colon Rectum       Date:  2004-04-19       Impact factor: 4.585

2.  Peroperative observation of marginal artery bleeding; a predictor of anastomotic leakage.

Authors:  R Grace
Journal:  Br J Surg       Date:  1990-06       Impact factor: 6.939

Review 3.  Stapling instruments for intestinal anastomosis in colorectal surgery.

Authors:  B J Moran
Journal:  Br J Surg       Date:  1996-07       Impact factor: 6.939

Review 4.  Surgical staplers: a review.

Authors:  J McGuire; I C Wright; J N Leverment
Journal:  J R Coll Surg Edinb       Date:  1997-02

Review 5.  Stapled versus handsewn methods for colorectal anastomosis surgery.

Authors:  S A Lustosa; D Matos; A N Atallah; A A Castro
Journal:  Cochrane Database Syst Rev       Date:  2001

6.  Evaluation of the Proximate-ILS circular stapler. A prospective study.

Authors:  V W Fazio; D G Jagelman; I C Lavery; B A McGonagle
Journal:  Ann Surg       Date:  1985-01       Impact factor: 12.969

  6 in total
  3 in total

1.  Effectiveness of a new triple-row circular stapler in reducing the risk of colorectal anastomotic leakage: A historical control and propensity score-matched study.

Authors:  Junichi Mazaki; Kenji Katsumata; Tetsuo Ishizaki; Noritoshi Fukushima; Ryutaro Udo; Tomoya Tago; Kenta Kasahara; Hiroshi Kuwabara; Masanobu Enomoto; Yuichi Nagakawa; Akihiko Tsuchida
Journal:  Medicine (Baltimore)       Date:  2022-07-08       Impact factor: 1.817

2.  Early prediction of anastomotic leakage after laparoscopic rectal surgery using creactive protein.

Authors:  Dongai Jin; Li Chen
Journal:  Medicine (Baltimore)       Date:  2021-06-04       Impact factor: 1.817

3.  Comparison of standard 4-row versus 6-row3-D linear cutter stapler in creation of gastrointestinal system anastomoses: a prospective randomized trial.

Authors:  Alper Sozutek; Tahsin Colak; Ahmet Dag; Tolga Olmez
Journal:  Clinics (Sao Paulo)       Date:  2012-09       Impact factor: 2.365

  3 in total