Validation of the Accutrend lactate meter for hyperlactatemia screening during antiretroviral therapy in a resource-poor setting.

Ernesto Hernández Pérez1, Halima Dawood, Ulenta Chetty, Tonya M Esterhuizen, Maresce Bizaare.   

Abstract

BACKGROUND: The use of highly active antiretroviral therapy (HAART) results in multiple side effects that may jeopardize the life of the patient being treated with antiretroviral drugs. In resource-poor settings it is difficult to definitively diagnose lactic acidosis by laboratory measurement of lactate. Point-of-care (POC) devices are helpful in the measurement of lactate levels and have been validated in the intensive care unit setting, but not in a busy outpatient clinic. The objective of this study was to assess the sensitivity and specificity of the Accutrend lactate meter in the diagnosis of hyperlactatemia/lactic acidosis in patients on nucleoside reverse transcriptase inhibitor (NRTI)-containing regimens (stavudine). DESIGN AND METHODS: This was a cross-sectional study of 120 patients on HAART (lamivudine, stavudine, efavirenz, or nevirapine) with symptoms of/or recovering from hyperlactatemia/lactic acidosis. Simultaneous testing of the same blood sample was undertaken on the Accutrend handheld lactate analyzer and a reference instrument (Beckman CX7 Synchron machine). A venous lactate level <2.2mmol/l was considered as normal.
RESULTS: The mean lactate value obtained from the Accutrend meter was 2.89mmol/l and from the reference instrument was 2.78mmol/l. The standard deviation for Accutrend meter was 1.14mmol/l vs.1.42mmol/l for the Beckman instrument. The sensitivity obtained for the Accutrend meter was 95.9% (95% CI 87.7-98.9%) and the specificity 63.8% (95% CI 48.5-76.9%). The positive predictive value was 80.5% (95% CI 70.3-87.9%) and the negative predictive value was 90.9% (95% CI 74.5-97.6%).
CONCLUSIONS: The Accutrend lactate meter is an appropriate device for screening patients on HAART with symptoms of hyperlactatemia/lactic acidosis. The use of this device decreases analytic and intervention time, preventing further morbidity and mortality in patients on an NRTI (stavudine)-based regimen.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18511322     DOI: 10.1016/j.ijid.2008.03.007

Source DB:  PubMed          Journal:  Int J Infect Dis        ISSN: 1201-9712            Impact factor:   3.623


  13 in total

1.  Aggregate evaluable organ dysfunction predicts in-hospital mortality from sepsis in Uganda.

Authors:  Richard Ssekitoleko; Relana Pinkerton; Rose Muhindo; Sanjay Bhagani; Christopher C Moore
Journal:  Am J Trop Med Hyg       Date:  2011-10       Impact factor: 2.345

2.  Point-of-care capillary blood lactate measurements in human immunodeficiency virus-uninfected children with in utero exposure to human immunodeficiency virus and antiretroviral medications.

Authors:  Marilyn J Crain; Paige L Williams; Ray Griner; Katherine Tassiopoulos; Jennifer S Read; Lynne M Mofenson; Kenneth C Rich
Journal:  Pediatr Infect Dis J       Date:  2011-12       Impact factor: 2.129

3.  Hyperlactatemia and concurrent use of antiretroviral therapy among HIV infected patients in Uganda.

Authors:  M Waiswa; B B Byarugaba; P Ocama; H Mayanja-Kizza; E Seremba; S Ganguli; M Crowther; R Colebunders
Journal:  Afr Health Sci       Date:  2012-09       Impact factor: 0.927

4.  Reduced referral and case fatality rates for severe symptomatic hyperlactataemia in a South African public sector antiretroviral programme: a retrospective observational study.

Authors:  Charlotte Schutz; Andrew Boulle; Dave Stead; Kevin Rebe; Meg Osler; Graeme Meintjes
Journal:  AIDS Res Ther       Date:  2010-05-26       Impact factor: 2.250

5.  Dose-Dependent Response of Personal Glucose Meters to Nicotinamide Coenzymes: Applications to Point-of-Care Diagnostics of Many Non-Glucose Targets in a Single Step.

Authors:  Jingjing Zhang; Yu Xiang; Miao Wang; Ananda Basu; Yi Lu
Journal:  Angew Chem Int Ed Engl       Date:  2015-11-23       Impact factor: 15.336

6.  Portable lactate analyzer for measuring lactate in cerebrospinal fluid (CSF) and plasma - method-comparison evaluations.

Authors:  Sérgio Monteiro de Almeida; Jennifer Marquie-Beck; Archana Bhatt; Scott Letendre; Allen McCutchan; Ron Ellis
Journal:  Arq Neuropsiquiatr       Date:  2014-07       Impact factor: 1.420

Review 7.  Blood lactate as a predictor for in-hospital mortality in patients admitted acutely to hospital: a systematic review.

Authors:  Ole Kruse; Niels Grunnet; Charlotte Barfod
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2011-12-28       Impact factor: 2.953

8.  Acute metabolic response to fasted and postprandial exercise.

Authors:  Filipe Dinato de Lima; Ana Luiza Matias Correia; Denilson da Silva Teixeira; Domingos Vasco da Silva Neto; Ítalo Sávio Gonçalves Fernandes; Mário Boratto Xavier Viana; Mateus Petitto; Rodney Antônio da Silva Sampaio; Sandro Nobre Chaves; Simone Teixeira Alves; Renata Aparecida Elias Dantas; Márcio Rabelo Mota
Journal:  Int J Gen Med       Date:  2015-08-13

9.  Aerobic exercise training prevents heart failure-induced skeletal muscle atrophy by anti-catabolic, but not anabolic actions.

Authors:  Rodrigo W A Souza; Warlen P Piedade; Luana C Soares; Paula A T Souza; Andreo F Aguiar; Ivan J Vechetti-Júnior; Dijon H S Campos; Ana A H Fernandes; Katashi Okoshi; Robson F Carvalho; Antonio C Cicogna; Maeli Dal-Pai-Silva
Journal:  PLoS One       Date:  2014-10-17       Impact factor: 3.240

10.  A method-comparison study regarding the validity and reliability of the Lactate Plus analyzer.

Authors:  Sarah Hart; Kathryn Drevets; Micah Alford; Amanda Salacinski; Brian E Hunt
Journal:  BMJ Open       Date:  2013-02-27       Impact factor: 2.692

View more