Literature DB >> 18509656

Demonstration of the Adamkiewicz artery in patients with descending or thoracoabdominal aortic aneurysm: optimization of contrast-medium application for 64-detector-row CT angiography.

Daisuke Utsunomiya1, Yasuyuki Yamashita, Syuichiro Okumura, Joji Urata.   

Abstract

Our aim was to prospectively investigate the contrast agent concentration and the infusion rate to obtain optimal images of the Adamkiewicz artery by 64-row MDCT. Eighty patients were divided into four groups based on the following protocol: A, 100 mL of 300 mg I/mL at 5.0 mL/s; B, 100 mL of 350 mg I/mL at 5.0 mL/s; C, 100 mL of 300 mg I/mL at 3.5 mL/s; D, 100 mL of 350 mg I/mL at 3.5 mL/s. Quantitative evaluation was performed by calculating mean aortic attenuation value from T5 to L3 level. Visual evaluation of the Adamkiewicz artery was also performed. In a quantitative evaluation, the rapid injection (A, 473.4 +/- 82.6 HU; B, 506.7 +/- 71.9 HU) was significantly superior to the slow injection (C, 371.3 +/- 65.1 HU; D, 391.5 +/- 60.8 HU). In a visual evaluation, the Adamkiewicz artery was assessable in 15 of 20 (75%), 16 of 20 (80%), 9 of 20 (45%), and 10 of 20 (50%) patients in groups A, B, C, and D, respectively. The injection protocol of 1.75 g iodine/s provides both the adequate aortic attenuation of more than 450 HU to assess the Adamkiewicz artery and the best visualization of the Adamkiewicz artery in 64-row MDCT.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18509656     DOI: 10.1007/s00330-008-1036-4

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  17 in total

1.  Does the Adamkiewicz artery originate from the larger segmental arteries?

Authors:  T Koshino; G Murakami; K Morishita; T Mawatari; T Abe
Journal:  J Thorac Cardiovasc Surg       Date:  1999-05       Impact factor: 5.209

2.  Selective perfusion of preoperatively identified artery of Adamkiewicz during repair of thoracoabdominal aortic aneurysm.

Authors:  Satoshi Ohtsubo; Tsuyoshi Itoh; Yukio Okazaki; Koichi Matsumoto; Akira Kato
Journal:  J Thorac Cardiovasc Surg       Date:  2004-01       Impact factor: 5.209

3.  Anterior spinal artery and artery of Adamkiewicz detected by using multi-detector row CT.

Authors:  Kohsuke Kudo; Satoshi Terae; Takeshi Asano; Masaki Oka; Kenshi Kaneko; Satoshi Ushikoshi; Kazuo Miyasaka
Journal:  AJNR Am J Neuroradiol       Date:  2003-01       Impact factor: 3.825

Review 4.  MR angiography and CT angiography of the artery of Adamkiewicz: state of the art.

Authors:  Kunihiro Yoshioka; Hiroyuki Niinuma; Shigeru Ehara; Takayuki Nakajima; Motoyuki Nakamura; Kohei Kawazoe
Journal:  Radiographics       Date:  2006-10       Impact factor: 5.333

Review 5.  Surgery of the thoracic aorta.

Authors:  N T Kouchoukos; D Dougenis
Journal:  N Engl J Med       Date:  1997-06-26       Impact factor: 91.245

6.  The Adamkiewicz artery: demonstration by intra-arterial computed tomographic angiography.

Authors:  Junichi Nojiri; Koichi Matsumoto; Akira Kato; Takahiro Miho; Koujiro Furukawa; Satoshi Ohtsubo; Tsuyoshi Itoh; Sho Kudo
Journal:  Eur J Cardiothorac Surg       Date:  2006-12-19       Impact factor: 4.191

7.  Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography.

Authors:  D Fleischmann; G D Rubin; A A Bankier; K Hittmair
Journal:  Radiology       Date:  2000-02       Impact factor: 11.105

8.  Simulation of aortic peak enhancement on MDCT using a contrast material flow phantom: feasibility study.

Authors:  Kazuo Awai; Atsushi Hatcho; Yoshiharu Nakayama; Shinichiro Kusunoki; Duo Liu; Masahiro Hatemura; Yoshinori Funama; Masayuki Denbo; Natsuko Sato; Yasuyuki Yamashita
Journal:  AJR Am J Roentgenol       Date:  2006-02       Impact factor: 3.959

9.  Introduction of adjuncts and their influence on changing results in 402 consecutive thoracoabdominal aortic aneurysm repairs.

Authors:  Marc Schepens; Karl Dossche; Wim Morshuis; Robin Heijmen; Eric van Dongen; Huub Ter Beek; Hans Kelder; Eduard Boezeman
Journal:  Eur J Cardiothorac Surg       Date:  2004-05       Impact factor: 4.191

10.  The risk of ischemic spinal cord injury in patients undergoing graft replacement for thoracoabdominal aortic aneurysms.

Authors:  K Grabitz; W Sandmann; K Stühmeier; B Mainzer; E Godehardt; B Ohle; U Hartwich
Journal:  J Vasc Surg       Date:  1996-02       Impact factor: 4.268

View more
  10 in total

1.  3D reconstructions of spinal segmental arteries using CT angiography: applications in minimally invasive spinal procedures.

Authors:  D H Heo; Y J Cho; S H Sheen; M S Hong; S M Cho; S H Park
Journal:  AJNR Am J Neuroradiol       Date:  2010-05-27       Impact factor: 3.825

2.  Identifying the Adamkiewicz artery using 3-T time-resolved magnetic resonance angiography: its role in addition to multidetector computed tomography angiography.

Authors:  Hidenobu Takagi; Hideki Ota; Yutaka Natsuaki; Yoshiaki Komori; Koki Ito; Yoshikatsu Saiki; Kei Takase
Journal:  Jpn J Radiol       Date:  2015-10-26       Impact factor: 2.374

3.  Comparison of intra-aortic computed tomography angiography to conventional angiography in the presurgical visualization of the Adamkiewicz artery: first results in patients with thoracoabdominal aortic aneurysms.

Authors:  Frédéric Clarençon; Federico Di Maria; Evelyne Cormier; Julien Gaudric; Nader Sourour; Joseph Gabrieli; Christina Iosif; Catherine Jenny; Fabien Koskas; Jacques Chiras
Journal:  Neuroradiology       Date:  2013-10-02       Impact factor: 2.804

4.  The feasibility of a 64-slice MDCT for detection of the Adamkiewicz artery: comparison of the detection rate of intravenous injection CT angiography using a 64-slice MDCT versus intra-arterial and intravenous injection CT angiography using a 16-slice MDCT.

Authors:  Tatsuya Nishii; Atsushi K Kono; Noriyuki Negi; Hiromi Hashimura; Kensuke Uotani; Yutaka Okita; Kazuro Sugimura
Journal:  Int J Cardiovasc Imaging       Date:  2013-10-01       Impact factor: 2.357

5.  Filtered back projection revisited in low-kilovolt computed tomography angiography: sharp filter kernel enhances visualization of the artery of Adamkiewicz.

Authors:  Tatsuya Nishii; Akiyuki Kotoku; Yoshiro Hori; Yuji Matsuzaki; Yoshiaki Watanabe; Yoshiaki Morita; Atsushi K Kono; Hitoshi Matsuda; Tetsuya Fukuda
Journal:  Neuroradiology       Date:  2018-11-21       Impact factor: 2.804

6.  Simultaneous Evaluation of the Whole Aorta and Artery of Adamkiewicz by MDCT.

Authors:  Kei Takase
Journal:  Ann Vasc Dis       Date:  2011-11-30

7.  Advantages of 70-kV CT Angiography for the Visualization of the Adamkiewicz Artery: Comparison with 120-kV Imaging.

Authors:  S Shimoyama; T Nishii; Y Watanabe; A K Kono; K Kagawa; S Takahashi; K Sugimura
Journal:  AJNR Am J Neuroradiol       Date:  2017-09-14       Impact factor: 3.825

8.  Ultra-high-resolution CT angiography of the artery of Adamkiewicz: a feasibility study.

Authors:  Kunihiro Yoshioka; Ryoichi Tanaka; Hidenobu Takagi; Yuta Ueyama; Kei Kikuchi; Takuya Chiba; Kazumasa Arakita; Joanne D Schuijf; Yasuo Saito
Journal:  Neuroradiology       Date:  2017-10-28       Impact factor: 2.804

9.  Predictors of Adamkiewicz artery and anterior spinal artery detection through computerized tomographic angiography.

Authors:  Alexandre Campos Moraes Amato; Jose Rodrigues Parga Filho; Noedir Antonio Groppo Stolf
Journal:  SAGE Open Med       Date:  2017-06-02

10.  Detection of the artery of Adamkiewicz using multidetector row computed tomography in patients with spinal arteriovenous shunt disease.

Authors:  Sodai Hoshiai; Masanari Shiigai; Takahiro Konishi; Yasunobu Nakai; Tomohiko Masumoto
Journal:  Pol J Radiol       Date:  2020-03-19
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.