Literature DB >> 18509639

Is extreme flexion of the knee after total knee replacement a prerequisite for patient satisfaction?

Karthik Narayan1, George Thomas, Ravi Kumar.   

Abstract

The focus of this study was to evaluate the functional result and to specifically ascertain whether the absence of the ability to squat and sit cross-legged altered the patient's satisfaction level after a successful standard total knee replacement. Squatting and sitting cross-legged are common practices in Asia. These activities are not possible following standard total knee replacement. Patients were followed-up for a minimum of 12 months post surgery. Their level of satisfaction was assessed using a Likert scale. The Knee Society Score (KSS) was used to assess range of motion and function of the knee. Twenty-one out of 25 patients were satisfied with the surgical result in spite of an inability to squat. Deep knee flexion may not be an essential prerequisite for patient satisfaction after total knee replacement, even in a population where squatting and sitting cross-legged are part of the normal lifestyle.

Entities:  

Mesh:

Year:  2008        PMID: 18509639      PMCID: PMC2903112          DOI: 10.1007/s00264-008-0557-4

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  11 in total

Review 1.  Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants.

Authors:  S J Mulholland; U P Wyss
Journal:  Int J Rehabil Res       Date:  2001-09       Impact factor: 1.479

2.  The Bisurface total knee replacement: a unique design for flexion. Four-to-nine-year follow-up study.

Authors:  M Akagi; T Nakamura; Y Matsusue; T Ueo; K Nishijyo; E Ohnishi
Journal:  J Bone Joint Surg Am       Date:  2000-11       Impact factor: 5.284

3.  Preoperative factors influencing the range of movement after total knee arthroplasty for severe osteoarthritis.

Authors:  A Lizaur; L Marco; R Cebrian
Journal:  J Bone Joint Surg Br       Date:  1997-07

4.  Comparison of range of motion after standard and high-flexion posterior stabilised total knee replacement.

Authors:  F Y Ng; H L Wong; W P Yau; K Y Chiu; W M Tang
Journal:  Int Orthop       Date:  2007-09-22       Impact factor: 3.075

5.  The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system.

Authors:  F C Ewald
Journal:  Clin Orthop Relat Res       Date:  1989-11       Impact factor: 4.176

6.  Range of motion of standard and high-flexion posterior stabilized total knee prostheses. A prospective, randomized study.

Authors:  Young-Hoo Kim; Keun-Soo Sohn; Jun-Shik Kim
Journal:  J Bone Joint Surg Am       Date:  2005-07       Impact factor: 5.284

7.  Predictive range of motion after total knee replacement.

Authors:  M A Ritter; E A Stringer
Journal:  Clin Orthop Relat Res       Date:  1979-09       Impact factor: 4.176

8.  Total condylar knee replacement. A study of factors influencing range of motion as late as two years after arthroplasty.

Authors:  D J Schurman; J N Parker; D Ornstein
Journal:  J Bone Joint Surg Am       Date:  1985-09       Impact factor: 5.284

9.  Patient outcomes after knee replacement.

Authors:  D A Heck; R L Robinson; C M Partridge; R M Lubitz; D A Freund
Journal:  Clin Orthop Relat Res       Date:  1998-11       Impact factor: 4.176

10.  Design may be counterproductive for optimizing flexion after TKR.

Authors:  Chitranjan S Ranawat
Journal:  Clin Orthop Relat Res       Date:  2003-11       Impact factor: 4.176

View more
  3 in total

1.  Single-radius, multidirectional total knee replacement.

Authors:  Jean-Yves Jenny; Rolf Miehlke; Dominique Saragaglia; Robert Geyer; Numa Mercier; Jean-Yves Schoenahl; Birger Thiel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-08-28       Impact factor: 4.342

2.  Role of Arthroscopic Surgery in Degenerative Knees with Mechanical Symptoms.

Authors:  Ravi Gupta; Anubhav Malhotra; Aditya Singla; Ashwani Soni; Sudhir Kumar Garg; Dinesh Kumar Walia
Journal:  Indian J Orthop       Date:  2019 May-Jun       Impact factor: 1.251

3.  Is Achieving High Flexion Necessary for Satisfaction after Total Knee Arthroplasty in Indian Patients?

Authors:  Ashutosh Purushottam Mavalankar; Shubha Rani
Journal:  Indian J Orthop       Date:  2019 Mar-Apr       Impact factor: 1.251

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.