Literature DB >> 18506589

A flow-through capnometer for obstructive sleep apnea.

Shinji Yamamori1, Yuji Takasaki, Makoto Ozaki, Hiroshi Iseki.   

Abstract

INTRODUCTION: Capnogram is often distorted due to aspiration of expired gas when a sidestream capnometer is used for non-intubated, spontaneously breathing condition. The purpose of this study was to make a flow-through capnometer without aspiration and to check if this capnometer precisely detected apnea during obstructive sleep apnea (OSA).
METHODS: (1) Flow-through capnometer The capnometer consisted of a flow-through etCO(2) sensor, cap-ONE, and an accompanying capnometer. The size of cap-ONE was small enough to be fitted under the nose where gas expired from the nose and the mouth passed through. Thus, the expired gas to be measured is directly blown into the cap-ONE. (2) The cap-ONE using a spontaneously breathing model Capnograms obtained by the cap-ONE and sidestream capnometers during nasal and oral breathing under normal and reduced ventilation were compared with a reference capnogram. (3) Clinical study with OSA patients With nineteen OSA patients capnograms during apnea events diagnosed as OSA by polysomnography were examined using the cap-ONE. (4) Simulation study with an OSA model Apnea in which inspiratory flow was zero and small expiratory flows repeated was produced. Capnograms and apnea detection were compared between the cap-ONE and sidestream capnometers.
RESULTS: In the spontaneouly breathing model capnograms and etCO(2) of the cap-ONE during nasal and oral breathing were almost identical with the reference capnogram but those of sidetream capnometers during oral breathing were significantly reduced. In the clinical study 41% of total OSA events showed capnograms with prolonged and elevated phase with small ripples. In a simulation study reduction of CO(2) tension during no-inspiration was small and apnea was successfully detected with the cap-ONE. However, with sidestream capnometers the reduction of CO(2) tension was large and apnea was not detected.
CONCLUSIONS: We concluded that the cap-ONE can record capnograms with minimum distortion and detect apnea reliably during OSA.

Entities:  

Mesh:

Year:  2008        PMID: 18506589     DOI: 10.1007/s10877-008-9126-z

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  15 in total

1.  Elimination of cardiogenic oscillations in the capnograph by applying low positive end-expiratory pressure (PEEP).

Authors:  R Marks; A Sidi
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

2.  Respiratory monitoring of carbon dioxide and oxygen: a ten-year perspective.

Authors:  M Weingarten
Journal:  J Clin Monit       Date:  1990-07

3.  Sleep and respiration: terminology and methodology.

Authors:  P West; M H Kryger
Journal:  Clin Chest Med       Date:  1985-12       Impact factor: 2.878

4.  Capnometers.

Authors:  L R Mogue; B Rantala
Journal:  J Clin Monit       Date:  1988-04

5.  [Evaluation of a compact device for capnometry of main-stream type compared with one of side-stream type in a postoperative care unit].

Authors:  Jobutada Morioka; Shinji Yamamori; Makoto Ozaki
Journal:  Masui       Date:  2006-12

6.  Thermal skin burns from a carbon dioxide analyzer in children.

Authors:  R F Reder; E G Brown; R A DeAsla; R A Jurado
Journal:  Ann Thorac Surg       Date:  1983-03       Impact factor: 4.330

7.  End tidal carbon dioxide monitoring in spontaneously breathing, nonintubated patients. A clinical comparison between conventional sidestream and microstream capnometers.

Authors:  A Casati; G Gallioli; R Passaretta; M Scandroglio; E Bignami; G Torri
Journal:  Minerva Anestesiol       Date:  2001-04       Impact factor: 3.051

8.  Obstructive sleep apnea uncovered after high spinal anesthesia: a case report.

Authors:  Paul M Wieczorek; Francesco Carli
Journal:  Can J Anaesth       Date:  2005 Aug-Sep       Impact factor: 5.063

9.  Recognition of cardiogenic artifact in pediatric capnograms.

Authors:  T C Smith; A Green; P Hutton
Journal:  J Clin Monit       Date:  1994-07

10.  End-tidal carbon dioxide pressure in neonates and infants measured by aspiration and flow-through capnography.

Authors:  J M Badgwell; J E Heavner
Journal:  J Clin Monit       Date:  1991-10
View more
  2 in total

1.  Flow-through versus sidestream capnometry for detection of end tidal carbon dioxide in the sedated patient.

Authors:  Derek J Sakata; Isao Matsubara; Nishant A Gopalakrishnan; Dwayne R Westenskow; Julia L White; Shinji Yamamori; Talmage D Egan; Nathan L Pace
Journal:  J Clin Monit Comput       Date:  2009-03-20       Impact factor: 2.502

2.  Novel mainstream capnometer system is safe and feasible even under CO2 insufflation during ERCP-related procedure: a pilot study.

Authors:  Yoichi Takimoto; Eisuke Iwasaki; Tatsuhiro Masaoka; Seiichiro Fukuhara; Shintaro Kawasaki; Takashi Seino; Tadashi Katayama; Kazuhiro Minami; Hiroki Tamagawa; Yujiro Machida; Haruhiko Ogata; Takanori Kanai
Journal:  BMJ Open Gastroenterol       Date:  2019-02-28
  2 in total