Literature DB >> 18504765

Investigating exchange and multicomponent relaxation in fully-balanced steady-state free precession imaging.

Sean C L Deoni1, Brian K Rutt, Derek K Jones.   

Abstract

PURPOSE: To investigate the effect of chemical exchange and multicomponent relaxation on the rapid T(2) mapping method, DESPOT2 (driven equilibrium single pulse observation of T(2)) and the steady-state free precession (SSFP) sequence upon which it is based. Although capable of rapid T(2) determination, an assumption implicit of the method is single-component relaxation. In many biological tissues (such as white and gray matter), it is well established that the T(2) decay curve is more accurately described by the summation of more than one relaxation species.
MATERIALS AND METHODS: The effects of exchange were first incorporated into the general SSFP magnetization expressions and its effect on the measured SSFP signal investigated using Bloch-McConnell simulations. Corresponding imaging experiments were performed to support the presented theory.
RESULTS: Simulations show the measured multicomponent SSFP signal may be expressed as a linear summation of signal from each species under usual imaging conditions where the repetition time is much less than T(2). Imaging experiments performed using dairy cream demonstrate strong agreement with the presented theory. Finally, using a dairy cream model, we demonstrate quantification of multicomponent relaxation from multiangle SSFP data for the first time, showing good agreement with reference spin-echo values.
CONCLUSION: SSFP and DESPOT2 may provide a new method for investigating multicomponent systems, such as human brain, and disease processes, such as multiple sclerosis. 2008 Wiley-Liss, Inc

Entities:  

Mesh:

Year:  2008        PMID: 18504765     DOI: 10.1002/jmri.21079

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  23 in total

1.  Limitations of rapid myelin water quantification using 3D bSSFP.

Authors:  C Lenz; M Klarhöfer; K Scheffler
Journal:  MAGMA       Date:  2010-04-28       Impact factor: 2.310

2.  Incorporation of nonzero echo times in the SPGR and bSSFP signal models used in mcDESPOT.

Authors:  Mustapha Bouhrara; Richard G Spencer
Journal:  Magn Reson Med       Date:  2015-09-26       Impact factor: 4.668

3.  Probing signal phase in direct visualization of short transverse relaxation time component (ViSTa).

Authors:  Daeun Kim; Hyo Min Lee; Se-Hong Oh; Jongho Lee
Journal:  Magn Reson Med       Date:  2014-08-22       Impact factor: 4.668

Review 4.  Advances in magnetic resonance neuroimaging.

Authors:  Michael E Moseley; Chunlei Liu; Sandra Rodriguez; Thomas Brosnan
Journal:  Neurol Clin       Date:  2009-02       Impact factor: 3.806

5.  31 P magnetic resonance fingerprinting for rapid quantification of creatine kinase reaction rate in vivo.

Authors:  Charlie Y Wang; Yuchi Liu; Shuying Huang; Mark A Griswold; Nicole Seiberlich; Xin Yu
Journal:  NMR Biomed       Date:  2017-09-15       Impact factor: 4.044

Review 6.  Characterization of cerebral white matter properties using quantitative magnetic resonance imaging stains.

Authors:  Andrew L Alexander; Samuel A Hurley; Alexey A Samsonov; Nagesh Adluru; Ameer Pasha Hosseinbor; Pouria Mossahebi; Do P M Tromp; Elizabeth Zakszewski; Aaron S Field
Journal:  Brain Connect       Date:  2012-01-27

7.  Analysis of mcDESPOT- and CPMG-derived parameter estimates for two-component nonexchanging systems.

Authors:  Mustapha Bouhrara; David A Reiter; Hasan Celik; Kenneth W Fishbein; Richard Kijowski; Richard G Spencer
Journal:  Magn Reson Med       Date:  2015-07-03       Impact factor: 4.668

8.  Balanced Steady-State Free Precession (bSSFP) from an effective field perspective: Application to the detection of chemical exchange (bSSFPX).

Authors:  Shu Zhang; Zheng Liu; Aaron Grant; Jochen Keupp; Robert E Lenkinski; Elena Vinogradov
Journal:  J Magn Reson       Date:  2016-12-08       Impact factor: 2.229

9.  Correction of main and transmit magnetic field (B0 and B1) inhomogeneity effects in multicomponent-driven equilibrium single-pulse observation of T1 and T2.

Authors:  Sean C L Deoni
Journal:  Magn Reson Med       Date:  2010-12-08       Impact factor: 4.668

10.  Simultaneous multi-angular relaxometry of tissue with MRI (SMART MRI): Theoretical background and proof of concept.

Authors:  Alexander L Sukstanskii; Jie Wen; Anne H Cross; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2016-03-15       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.