Literature DB >> 18503927

Cardiac output monitoring: comparison of a new arterial pressure waveform analysis to the bolus thermodilution technique in patients undergoing off-pump coronary artery bypass surgery.

Yatin Mehta1, Rajesh Kumar Chand, Ravindra Sawhney, Milind Bhise, Ajmer Singh, Naresh Trehan.   

Abstract

OBJECTIVE: To analyze the clinical agreement between the conventional intermittent bolus thermodilution (TD) technique and a new arterial pressure waveform analysis (APCO) technique (FloTrac; Edward Lifesciences, Irvine, CA) for cardiac output (CO) estimation.
DESIGN: Prospective observational clinical study.
SETTING: Cardiac surgery operating room of a tertiary care cardiac center. PARTICIPANTS: Twelve patients undergoing elective off-pump coronary artery bypass (OPCAB) surgery.
MEASUREMENTS AND MAIN RESULTS: CO was determined by 2 different methods: TD and APCO at 8 time points (preinduction, postinduction, poststernotomy, left internal mammary artery to left anterior descending artery anastomosis, left [obtuse marginal/diagonal] anastomosis, right [right coronary/posterior descending coronary artery] anastomosis, postprotamine administration, and poststernal closure) in 12 patients undergoing elective OPCAB surgery. The mean bias and limits of agreement (2 standard deviations) expressed in liters per minute at respective points of measurement were -0.54 +/- 1.12, -0.37 +/- 1.0, -0.42 +/- 1.50, -0.25 +/- 1.18, -0.31 + 1.28, +/-0.41 +/- 1.0, 0.06 +/- 1.50, and 0.09 +/- 1.40.
CONCLUSION: Good agreement was found between the CO values obtained by the APCO and TD techniques throughout the intraoperative period including the period of coronary artery graft surgery.

Entities:  

Mesh:

Year:  2008        PMID: 18503927     DOI: 10.1053/j.jvca.2008.02.015

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  18 in total

Review 1.  Cardiac output monitoring devices: an analytic review.

Authors:  Jahan Porhomayon; Ali El-Solh; Peter Papadakos; Nader Djalal Nader
Journal:  Intern Emerg Med       Date:  2011-12-07       Impact factor: 3.397

2.  Comparison of cardiac output measures by transpulmonary thermodilution, pulse contour analysis, and pulmonary artery thermodilution during off-pump coronary artery bypass surgery: a subgroup analysis of the cardiovascular anaesthesia registry at a single tertiary centre.

Authors:  Youn Joung Cho; Chang-Hoon Koo; Tae Kyong Kim; Deok Man Hong; Yunseok Jeon
Journal:  J Clin Monit Comput       Date:  2015-10-01       Impact factor: 2.502

3.  Agreement in hemodynamic monitoring during orthotopic liver transplantation: a comparison of FloTrac/Vigileo at two monitoring sites with pulmonary artery catheter thermodilution.

Authors:  Matthew Lee; Laurence Weinberg; Brett Pearce; Nicholas Scurrah; David A Story; Param Pillai; Peter R McCall; Larry P McNicol; Philip J Peyton
Journal:  J Clin Monit Comput       Date:  2016-02-16       Impact factor: 2.502

4.  Applications of minimally invasive cardiac output monitors.

Authors:  Jahan Porhomayon; Gino Zadeii; Samuel Congello; Nader D Nader
Journal:  Int J Emerg Med       Date:  2012-04-24

Review 5.  Methods in pharmacology: measurement of cardiac output.

Authors:  Bart F Geerts; Leon P Aarts; Jos R Jansen
Journal:  Br J Clin Pharmacol       Date:  2011-03       Impact factor: 4.335

6.  Cardiac output monitoring in septic shock: evaluation of the third-generation Flotrac-Vigileo.

Authors:  Sophie Marqué; Antoine Gros; Loic Chimot; Arnaud Gacouin; Sylvain Lavoué; Christophe Camus; Yves Le Tulzo
Journal:  J Clin Monit Comput       Date:  2013-01-30       Impact factor: 2.502

Review 7.  Newer methods of cardiac output monitoring.

Authors:  Yatin Mehta; Dheeraj Arora
Journal:  World J Cardiol       Date:  2014-09-26

8.  Utility of stroke volume variation measured using non-invasive bioreactance as a predictor of fluid responsiveness in the prone position.

Authors:  Jeong Jin Min; Jong-Hwan Lee; Kwan Young Hong; Soo Joo Choi
Journal:  J Clin Monit Comput       Date:  2016-03-10       Impact factor: 2.502

Review 9.  Pulse waveform hemodynamic monitoring devices: recent advances and the place in goal-directed therapy in cardiac surgical patients.

Authors:  Adham Hendy; Şerban Bubenek
Journal:  Rom J Anaesth Intensive Care       Date:  2016-04

10.  Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients.

Authors:  Daniel De Backer; Gernot Marx; Andrew Tan; Christopher Junker; Marc Van Nuffelen; Lars Hüter; Willy Ching; Frédéric Michard; Jean-Louis Vincent
Journal:  Intensive Care Med       Date:  2010-12-10       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.