Literature DB >> 18500085

Central corneal thickness measurements by ultrasound, Orbscan II, and Visante OCT after LASIK for myopia.

Arthur C K Cheng1, Srinivas K Rao, Silvania Lau, Chris K S Leung, Dennis S C Lam.   

Abstract

PURPOSE: To compare central corneal thickness measurements obtained with Orbscan II scanning slit topography, Visante optical coherence tomography (OCT), and ultrasound pachymetry in myopic eyes after LASIK.
METHODS: This retrospective study included 34 consecutive patients (68 eyes) who underwent LASIK for the correction of myopia. Six months after surgery, central corneal thickness measurements were obtained using ultrasound pachymetry, Orbscan scanning slit topography, and Visante OCT. Data were analyzed using paired sample t test, Bland and Altman plot, and linear regression.
RESULTS: Average postoperative central corneal thickness was 436.65+/-43.82 microm for ultrasound pachymetry, 422.84+/-51.04 microm for Orbscan (0.89 acoustic equivalent correction factor), and 422.26+/-42.46 microm for Visante. Compared to the ultrasound measurement, Orbscan and Visante measurements significantly underestimated the corneal thickness by 13.81+/-17.34 microm (P<.01) and 14.38+/-10.13 microm (P<.01), respectively.
CONCLUSIONS: Both Orbscan and Visante OCT underestimated central corneal thickness compared to ultrasound pachymetry 6 months after LASIK, although measurements obtained with Visante OCT had better agreement and correlation with ultrasound pachymetry than with Orbscan.

Entities:  

Mesh:

Year:  2008        PMID: 18500085     DOI: 10.3928/1081597X-20080401-08

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  7 in total

1.  Central Corneal Thickness in Highly Myopic Eyes: Inter-device Agreement of Ultrasonic Pachymetry, Pentacam and Orbscan II Before and After Photorefractive Keratectomy.

Authors:  Nader Nassiri; Kourosh Sheibani; Sare Safi; Saman Nassiri; Alireza Ziaei; Alireza Ziaee; Farnaz Haji; Shiva Mehravaran; Nariman Nassiri
Journal:  J Ophthalmic Vis Res       Date:  2014-01

2.  Comparison of central corneal thickness with four noncontact devices: An agreement analysis of swept-source technology.

Authors:  Erhan Ozyol; Pelin Özyol
Journal:  Indian J Ophthalmol       Date:  2017-06       Impact factor: 1.848

3.  Accuracy of Cirrus HD-OCT and Topcon SP-3000P for measuring central corneal thickness.

Authors:  Jorge A Calvo-Sanz; Javier Ruiz-Alcocer; Miguel A Sánchez-Tena
Journal:  J Optom       Date:  2017-02-21

4.  Optical Coherence Tomography Reveals Sigmoidal Crystalline Lens Changes during Accommodation.

Authors:  George A Gibson; Fiona E Cruickshank; James S Wolffsohn; Leon N Davies
Journal:  Vision (Basel)       Date:  2018-08-21

5.  Measurement of corneal thickness using Pentacam HR versus Nidek CEM-530 specular microscopy.

Authors:  Maddalena De Bernardo; Palmiro Cornetta; Giuseppe Marotta; Giulio Salerno; Ilaria De Pascale; Nicola Rosa
Journal:  J Int Med Res       Date:  2019-12-26       Impact factor: 1.671

6.  Longitudinal Evaluation of Cornea With Swept-Source Optical Coherence Tomography and Scheimpflug Imaging Before and After Lasik.

Authors:  Tommy C Y Chan; Sayantan Biswas; Marco Yu; Vishal Jhanji
Journal:  Medicine (Baltimore)       Date:  2015-07       Impact factor: 1.889

7.  Repeatability and agreement of five imaging systems for measuring anterior segment parameters in healthy eyes.

Authors:  Mukesh Kumar; Rohit Shetty; Chaitra Jayadev; Harsha L Rao; Debarun Dutta
Journal:  Indian J Ophthalmol       Date:  2017-04       Impact factor: 1.848

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.