Literature DB >> 18499011

Analysis of clear corneal incision integrity in an ex vivo model.

William May1, Juan Castro-Combs, Walter Camacho, Priscila Wittmann, Ashley Behrens.   

Abstract

PURPOSE: To determine the most favorable sutureless incision configuration to minimize extraocular fluid inflow after cataract surgery.
SETTING: The Wilmer Eye Institute, Baltimore, Maryland, USA.
METHODS: Five fresh human eyes were used in the study. Two 27-gauge needles connected to a saline solution bag and a digital manometer were inserted through the limbus 180 degrees from each other. Intraocular pressure (IOP) was maintained at 15 to 20 mm Hg. Three incisions were performed in different quadrants of each cornea: uniplanar 1.0 mm and 3.0 mm tunnel lengths and 2-step 3.0 mm tunnel length. India ink was applied to the incision site, and IOP fluctuation was induced by applying pressure to the limbal area of the opposite quadrant using an ophthalmodynamometer. Imaging was performed before and after pressure application.
RESULTS: The linear distance of India ink inflow after pressure application was higher than the prepressure measurements in the 1.0 mm and 3.0 mm incision groups (P = .039 and P = .023, respectively). The maximum mean of inflow after pressure application was not higher than the prepressure measurement in the 2-step incision group (P = .105). The total ink area measured before and after pressure applications in the incisions of the 3 groups was not significantly different (P = .285).
CONCLUSIONS: Intraocular pressure fluctuations may promote entry of bacteria-size particles into the eye when 1.0 mm and 3.0 mm single-plane incisions are performed. Stepped incisions seem to be more resistant to inflow in the presence of IOP fluctuation.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18499011     DOI: 10.1016/j.jcrs.2008.01.038

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  9 in total

1.  Seidel and India ink tests assessment of different clear cornea side-port incision configurations.

Authors:  Fabiana K Kashiwabuchi; Yasin A Khan; Murilo W Rodrigues; Jiangxia Wang; Peter J McDonnell; Yassine J Daoud
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-05-24       Impact factor: 3.117

Review 2.  [Incisions for biaxial and coaxial microincision cataract surgery].

Authors:  M Müller; T Kohnen
Journal:  Ophthalmologe       Date:  2010-02       Impact factor: 1.059

3.  Intraocular pressure and wound state immediately after long versus short clear corneal incision cataract surgery.

Authors:  Ken Hayashi; Hiroshi Sasaki; Shin-Ichi Manabe; Akira Hirata
Journal:  Jpn J Ophthalmol       Date:  2018-10-06       Impact factor: 2.447

4.  New thin-film adhesive for sealing full-thickness corneal incisions in rabbits.

Authors:  Jackie Tan; Leslie John Ray Foster; Frank James Lovicu; Stephanie Louise Watson
Journal:  J Cataract Refract Surg       Date:  2022-03-01       Impact factor: 3.528

5.  Risk factors for endothelial cell loss after phacoemulsification: comparison in different anterior chamber depth groups.

Authors:  Yang Kyeung Cho; Hwa Seok Chang; Man Soo Kim
Journal:  Korean J Ophthalmol       Date:  2010-02-05

6.  Immediate changes in intraocular pressure after clear corneal micro-incision versus small-incision cataract surgery.

Authors:  Ken Hayashi; Motoaki Yoshida; Koichi Yoshimura
Journal:  Jpn J Ophthalmol       Date:  2014-06-28       Impact factor: 2.447

7.  Wound stability and surgically induced corneal astigmatism after transconjunctival single-plane sclerocorneal incision cataract surgery.

Authors:  Ken Hayashi; Soichiro Ogawa; Motoaki Yoshida; Koichi Yoshimura
Journal:  Jpn J Ophthalmol       Date:  2016-10-06       Impact factor: 2.447

Review 8.  Cataract surgery and methods of wound closure: a review.

Authors:  Cynthia Matossian; Sarah Makari; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2015-05-22

9.  Perioperative modulating factors on astigmatism in sutured cataract surgery.

Authors:  Yang Kyeung Cho; Man Soo Kim
Journal:  Korean J Ophthalmol       Date:  2009-12-04
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.