Effect of excimer laser repetition rate on outcomes after photorefractive keratectomy.

George D Kymionis1, Vasilios F Diakonis, George Kounis, Dimitrios I Bouzoukis, Eirineos Gkenos, Harilaos Ginis, Sonia H Yoo, Ioannis G Pallikaris.   

Abstract

PURPOSE: To compare the refractive outcomes after photorefractive keratectomy (PRK) for low to moderate myopic corrections using 2 excimer lasers with different repetition rates (200 Hz and 400 Hz).
SETTING: University refractive surgery center.
METHODS: This retrospective study included all consecutive patients who underwent PRK using the 200 Hz or the 400 Hz Allegretto laser platform (WaveLight Laser Technologie AG). Thirty-five patients (70 eyes) and 29 patients (58 eyes) had PRK with the 200 Hz platform and the 400 Hz platform, respectively, using the same surgical technique.
RESULTS: The mean follow-up was 13.22 months +/- 1.16 (SD) (range 11 to 15 months). No intraoperative or early postoperative (eg, late reepithelialization) complications were found in either group. At 1 year, 66 eyes (94.2%) in the 200 Hz group and 56 eyes (96.6%) in the 400 Hz group were within +/-1.00 diopter of the attempted correction. At 3 months, 20 eyes (29%) in the 200 Hz group and 27 eyes (46%) in the 400 Hz group had mild or moderate corneal haze (P = .03). These corneas showed progressive clearing over subsequent months without statistically significant differences in haze formation between the 2 groups. Twelve months after PRK, all corneas in both groups were clear.
CONCLUSION: Photorefractive keratectomy for the treatment of low to moderate refractive errors using a 200 Hz or 400 Hz excimer laser gave comparable results.

Entities:  

Mesh:

Year:  2008        PMID: 18498995     DOI: 10.1016/j.jcrs.2008.02.022

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  3 in total

1.  Photorefractive keratectomy for myopia and myopic astigmatism correction using the WaveLight Allegretto Wave Eye-Q excimer laser system.

Authors:  Esmeralda Costa; Nuno Franqueira; Andreia M Rosa; Cristina Tavares; Maria J Quadrado; Conceição Lobo; Joaquim N Murta
Journal:  Int Ophthalmol       Date:  2013-07-20       Impact factor: 2.031

2.  Myopic Laser-Assisted Subepithelial Keratectomy (LASEK) outcomes using three different excimer laser platforms: a retrospective observational study.

Authors:  Isabel Rodríguez-Pérez; Juan Gros-Otero; Miguel A Teus; Rafael Cañones; Montserrat García-González
Journal:  BMC Ophthalmol       Date:  2019-10-15       Impact factor: 2.209

3.  Shielding effect of the smoke plume by the ablation of excimer lasers.

Authors:  Csaba Szekrényesi; Huba Kiss; Tamás Filkorn; Zoltán Zsolt Nagy
Journal:  BMC Ophthalmol       Date:  2018-10-23       Impact factor: 2.209

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.