The 12 cc Penn State pulsatile pediatric ventricular assist device: flow field observations at a reduced beat rate with application to weaning.

Breigh N Roszelle1, Benjamin T Cooper, Tobias C Long, Steven Deutsch, Keefe B Manning.   

Abstract

Ventricular assist devices (VADs) have become a viable option for adult patients with end-stage heart failure during the bridge-to-transplant period and have recently shown promise in aiding in myocardial recovery. Because the number of available organs is insufficient, mechanical circulatory support systems such as VADs are also being developed for use in pediatric patients. During myocardial recovery, the system must be weaned from the patient to prepare for explant; for pulsatile devices, this often includes a reduction in flow rate, which can change the fluid dynamics of the device. These changes in flow need to be monitored because strong diastolic rotational flow, no areas of blood stasis, low blood residence time, and wall shear rates above 500 s, can help prevent thrombus deposition. Particle image velocimetry was used to observe the planar flow patterns and wall shear rates of the 12 cc Penn State Pneumatic Pediatric VAD (PVAD) at a normal operating condition and a reduced beat rate. At the reduced beat rate, the PVAD showed an earlier loss of rotational pattern, increased blood residence time, and an overall reduction in wall shear rate at the outer walls. Because this reduction in flow rate could lead to a possible increase in thrombus deposition, it may be necessary to look into other options for weaning a patient from the PVAD.

Entities:  

Mesh:

Year:  2008        PMID: 18496284     DOI: 10.1097/MAT.0b013e3181695cfe

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  9 in total

1.  The national heart, lung, and blood institute pediatric circulatory support program: a summary of the 5-year experience.

Authors:  J Timothy Baldwin; Harvey S Borovetz; Brian W Duncan; Mark J Gartner; Robert K Jarvik; William J Weiss
Journal:  Circulation       Date:  2011-03-22       Impact factor: 29.690

2.  Toward the Virtual Benchmarking of Pneumatic Ventricular Assist Devices: Application of a Novel Fluid-Structure Interaction-Based Strategy to the Penn State 12 cc Device.

Authors:  Alessandro Caimi; Francesco Sturla; Bryan Good; Marco Vidotto; Rachele De Ponti; Filippo Piatti; Keefe B Manning; Alberto Redaelli
Journal:  J Biomech Eng       Date:  2017-08-01       Impact factor: 2.097

Review 3.  Function of alternative splicing.

Authors:  Olga Kelemen; Paolo Convertini; Zhaiyi Zhang; Yuan Wen; Manli Shen; Marina Falaleeva; Stefan Stamm
Journal:  Gene       Date:  2012-08-15       Impact factor: 3.688

4.  The influence of operational protocol on the fluid dynamics in the 12 cc Penn state pulsatile pediatric ventricular assist device: the effect of end-diastolic delay.

Authors:  Benjamin T Cooper; Breigh N Roszelle; Tobias C Long; Steven Deutsch; Keefe B Manning
Journal:  Artif Organs       Date:  2010-04       Impact factor: 3.094

5.  Flow visualization of a pediatric ventricular assist device during stroke volume reductions related to weaning.

Authors:  Breigh N Roszelle; Steven Deutsch; William J Weiss; Keefe B Manning
Journal:  Ann Biomed Eng       Date:  2011-03-15       Impact factor: 3.934

Review 6.  Towards non-thrombogenic performance of blood recirculating devices.

Authors:  D Bluestein; K B Chandran; K B Manning
Journal:  Ann Biomed Eng       Date:  2010-02-04       Impact factor: 3.934

7.  Flow visualization of three-dimensionality inside the 12 cc Penn State pulsatile pediatric ventricular assist device.

Authors:  Breigh N Roszelle; Steven Deutsch; Keefe B Manning
Journal:  Ann Biomed Eng       Date:  2010-02       Impact factor: 3.934

8.  The influence of device position on the flow within the Penn State 12 cc pediatric ventricular assist device.

Authors:  Markus Schönberger; Steven Deutsch; Keefe B Manning
Journal:  ASAIO J       Date:  2012 Sep-Oct       Impact factor: 2.872

9.  Particle image velocimetry tests on pediatric 45-cc and 30-cc ventricle assist devices: effects of heart rate on VAD operation.

Authors:  Dariusz Witkowski; Damian Obidowski; Piotr Reorowicz; Daniel Jodko; Krzysztof Jozwik
Journal:  Int J Artif Organs       Date:  2017-07-08       Impact factor: 1.595

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.