Literature DB >> 18491544

Peripheral dose measurement for CyberKnife radiosurgery with upgraded linac shielding.

Cynthia F Chuang1, David A Larson, Andrea Zytkovicz, Vernon Smith, Paula L Petti.   

Abstract

The authors investigated the peripheral dose reduction for CyberKnife radiosurgery treatments after the installation of a linac shielding upgrade. As in a previous investigation, the authors considered two treatment plans, one for a hypothetical target in the brain and another for a target in the thorax, delivered to an anthropomorphic phantom. The results of the prior investigation showed that the CyberKnife delivered significantly higher peripheral doses than comparable model C Gamma Knife or IMRT treatments. Current measurements, after the linac shielding upgrade, demonstrate that the additional shielding decreased the peripheral dose, expressed as a percentage of the delivered monitor units (MU), by a maximum of 59%. The dose reduction was greatest for cranial-caudal distances from the field edge less than 30 cm, and at these distances, the CyberKnife peripheral dose, expressed as a percentage of the delivered MU, is now comparable to that measured for the other treatment modalities in our previous investigation. For distances between 30 and 70 cm from the field edge, the additional shielding reduced the peripheral dose by between 20% and 55%. At these distances, the CyberKnife peripheral dose remains higher than doses measured in our previous study for the model C Gamma Knife and IMRT.

Mesh:

Year:  2008        PMID: 18491544     DOI: 10.1118/1.2889620

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Evaluation of the peripheral dose in stereotactic radiotherapy and radiosurgery treatments.

Authors:  Erika Di Betta; Laura Fariselli; Achille Bergantin; Federica Locatelli; Antonella Del Vecchio; Sara Broggi; Maria Luisa Fumagalli
Journal:  Med Phys       Date:  2010-07       Impact factor: 4.071

2.  Influence of Specific Treatment Parameters on Nontarget and Out-of-Field Doses in a Phantom Model of Prostate SBRT with CyberKnife and TrueBeam.

Authors:  Marta Kruszyna-Mochalska; Agnieszka Skrobala; Piotr Romanski; Adam Ryczkowski; Wiktoria Suchorska; Katarzyna Kulcenty; Igor Piotrowski; Dorota Borowicz; Kinga Graczyk; Natalia Matuszak; Julian Malicki
Journal:  Life (Basel)       Date:  2022-04-23

3.  Consideration of the radiation dose delivered away from the treatment field to patients in radiotherapy.

Authors:  Michael L Taylor; Tomas Kron
Journal:  J Med Phys       Date:  2011-04

4.  Peripheral doses in patients undergoing Cyberknife treatment for intracranial lesions. A single centre experience.

Authors:  Vassiliki Vlachopoulou; Christos Antypas; Harry Delis; Argyrios Tzouras; Nikolaos Salvaras; Dimitrios Kardamakis; George Panayiotakis
Journal:  Radiat Oncol       Date:  2011-11-14       Impact factor: 3.481

  4 in total