Literature DB >> 18490809

An assessment of GafChromic film for measuring 50 kV and 100 kV percentage depth dose curves.

Claire Lesley Fletcher1, John A Mills.   

Abstract

Percentage depth dose (PDD) curves were obtained for 50 kV and 100 kV x-rays on a Gulmay Medical D3000 DXR unit. Different dosimetry systems were compared including a Scanditronix Wellhofer small volume cylindrical ion chamber, a Wellhofer photon PFD diode, a PTW soft x-ray parallel plate chamber (N23342) and two types of radiochromic film: GafChromic EBT and GafChromic MD55. The PDD curves were also compared to BEAMnrc Monte Carlo predictions. GafChromic film was found to be a valid choice of dosimeter for measuring percentage depth dose curves at 100 kV and 50 kV. All the dosimeters showed agreement with predictions at depths greater than 10 mm, while near the surface GafChromic film and PFD diodes give the best agreement to Monte Carlo values.

Entities:  

Mesh:

Year:  2008        PMID: 18490809     DOI: 10.1088/0031-9155/53/11/N02

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Influence of difference in cross-sectional dose profile in a CTDI phantom on X-ray CT dose estimation: a Monte Carlo study.

Authors:  Tomonobu Haba; Shuji Koyama; Yoshihiro Ida
Journal:  Radiol Phys Technol       Date:  2013-11-24

2.  Dosimetry of a novel converging X-ray source for kilovoltage radiotherapy.

Authors:  Tyler Stalbaum; Larry Partain; Michael D Weil; Joon Kim; Jae Y Han; Michael J Plies; Hong Chen; Vitaliy Ziskin; Magdalena Bazalova-Carter; Samuel Song; Roy Rand; Douglas Boyd
Journal:  Med Phys       Date:  2021-08-25       Impact factor: 4.506

3.  Simplified method for creating a density-absorbed dose calibration curve for the low dose range from Gafchromic EBT3 film.

Authors:  Tatsuhiro Gotanda; Toshizo Katsuda; Rumi Gotanda; Tadao Kuwano; Takuya Akagawa; Nobuyoshi Tanki; Akihiko Tabuchi; Tetsunori Shimono; Yasuyuki Kawaji
Journal:  J Med Phys       Date:  2016 Oct-Dec

4.  Commissioning a 50-100 kV X-ray unit for skin cancer treatment.

Authors:  Ren-Dih Sheu; Allison Powers; Yeh-Chi Lo
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

5.  Real-time dosimetry with radiochromic films.

Authors:  Pierluigi Casolaro; Luigi Campajola; Giovanni Breglio; Salvatore Buontempo; Marco Consales; Andrea Cusano; Antonello Cutolo; Francesco Di Capua; Francesco Fienga; Patrizio Vaiano
Journal:  Sci Rep       Date:  2019-03-29       Impact factor: 4.379

6.  Determination of paramagnetic ferrous gel sensitivity in low energy x-ray beam produced by a miniature accelerator.

Authors:  Yassir Ben Ahmed; Jérémy Coulaud; Soléakhena Ken; Laure Parent
Journal:  PLoS One       Date:  2020-05-04       Impact factor: 3.240

7.  Patient-Specific Quality Assurance Using a 3D-Printed Chest Phantom for Intraoperative Radiotherapy in Breast Cancer.

Authors:  Yeonho Choi; Ik Jae Lee; Kwangwoo Park; Kyung Ran Park; Yeona Cho; Jun Won Kim; Ho Lee
Journal:  Front Oncol       Date:  2021-03-15       Impact factor: 6.244

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.