Literature DB >> 18490278

Non-invasive estimation of pressure gradients in regurgitant jets: an overdue consideration.

Alessandro Giardini1, Theresa A Tacy.   

Abstract

AIMS: This investigation sought to discern the relative accuracy of Doppler predictions of pressure drops in regurgitant jets across a broad spectrum of conditions, using an in vitro pulsatile flow model. METHODS AND
RESULTS: We studied the accuracy of Doppler pressure gradients derived from regurgitant jet peak velocities using the simplified Bernoulli equation (SBE) using an in vitro flow model of atrio-ventricular valve regurgitation. We observed overall a good correlation (r = 0.89, P < 0.0001) with actual pressure gradient, when there is normal fluid viscosity and the jet is free of wall interaction. However, we observed various degrees of underestimation of pressure gradient by Doppler when regurgitant chamber size was reduced (P = 0.0003), when fluid viscosity was increased (P < 0.0001), or in the presence of wall interaction (P < 0.0001). Chamber compliance had no effect on the accuracy of pressure gradient prediction (P = 0.36). Significant underestimation error in pressure gradient prediction by Doppler of up to 43.2% was observed.
CONCLUSION: When jet impingement or wall interaction are present, or when viscosity is increased, caution should be used in applying the SBE to a regurgitant jet, as significant underestimation in pressure gradient prediction may occur.

Entities:  

Mesh:

Year:  2008        PMID: 18490278     DOI: 10.1093/ejechocard/jen156

Source DB:  PubMed          Journal:  Eur J Echocardiogr        ISSN: 1532-2114


  4 in total

1.  In Vitro Simulation and Validation of the Circulation with Congenital Heart Defects.

Authors:  Richard S Figliola; Alessandro Giardini; Tim Conover; Tiffany A Camp; Giovanni Biglino; John Chiulli; Tain-Yen Hsia
Journal:  Prog Pediatr Cardiol       Date:  2010-12-01

Review 2.  Methods for measuring right ventricular function and hemodynamic coupling with the pulmonary vasculature.

Authors:  Alessandro Bellofiore; Naomi C Chesler
Journal:  Ann Biomed Eng       Date:  2013-02-20       Impact factor: 3.934

3.  Doppler echocardiography inaccurately estimates right ventricular pressure in children with elevated right heart pressure.

Authors:  Georgeann K Groh; Philip T Levy; Mark R Holland; Joshua J Murphy; Timothy J Sekarski; Craig L Myers; Diana P Hartman; Rebecca D Roiger; Gautam K Singh
Journal:  J Am Soc Echocardiogr       Date:  2013-10-30       Impact factor: 5.251

4.  Can echocardiographically estimated pulmonary arterial elastance be a non-invasive predictor of pulmonary vascular resistance?

Authors:  Neeraj Sinha; Srikala Devabhaktuni; Aparna Kadambi; John A McClung; Wilbert S Aronow; Stuart G Lehrman
Journal:  Arch Med Sci       Date:  2014-08-29       Impact factor: 3.318

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.