Electrochemical detection of low-copy number salivary RNA based on specific signal amplification with a hairpin probe.

Fang Wei1, Jianghua Wang, Wei Liao, Bernhard G Zimmermann, David T Wong, Chih-Ming Ho.   

Abstract

We developed a technique for electrochemical detection of salivary mRNA employing a hairpin probe (HP). Steric hindrance (SH) suppresses unspecific signal and generates a signal-on amplification process for target detection. The stem-loop configuration brings the reporter end of the probe into close proximity with the surface and makes it unavailable for binding with the mediator. Target binding opens the hairpin structure of the probe, and the mediator can then bind to the accessible reporter. Horseradish peroxidase is utilized to generate electrochemical signal. This signal-on process is characterized by a low basal signal, a strong positive readout and a large dynamic range. The SH is controlled via hairpin design and electrical field. By applying electric field control to HPs, the limit of detection of RNA is about 0.4 fM, which is 10 000-fold more sensitive than conventional linear probes. Endogenous Interleukin-8 mRNA is detected with the HP, and good correlation with the quantitative PCR technique is obtained. The resultant process allows a simple setup and by reducing the number of steps it is suited for the point-of-care detection of specific nucleic acid sequences from complex body fluids such as saliva.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18487624      PMCID: PMC2441804          DOI: 10.1093/nar/gkn299

Source DB:  PubMed          Journal:  Nucleic Acids Res        ISSN: 0305-1048            Impact factor:   16.971


INTRODUCTION

Molecular analysis of body fluids provides the potential for early cancer detection and subsequent increased treatment efficacy (1–3). Molecular markers released from tumors find their way into blood and/or other body fluids, and specific detection of biomarkers may enable disease identification in a noninvasive and specific manner (4,5). Saliva is easily accessible in a noninvasive manner, and can be collected with less patient discomfort relative to blood. In addition, the levels of interfering material (cells, DNA, RNA and proteins) and inhibitory substances are lower and less complex in saliva than in blood. This advantage has recently been shown in a thorough study of oral cancer mRNA markers (6). mRNAs were identified through microarray and validated according to established guidelines (7) by quantitative PCR (qPCR). Detecting salivary mRNA biomarkers adds a new dimension to saliva as a valuable diagnostic fluid. In this study, we aimed to develop a unique methodology for on-site testing of salivary mRNA. Electrochemistry is an excellent candidate for a point-of-care diagnostic method for RNA detection (8), not only because of its high sensitivity but also because of the simplicity of the instrument (9–13). However, due to the low concentration (∼fM) of salivary biomarkers and the complex background of saliva, conventional electrochemical amperometric detection methods do not meet the clinical diagnostic requirement of high signal-to-background ratio (SBR) for direct RNA detection in saliva. Recently, Plaxco's group reported a novel method of applying redox-labeled hairpin probes (HPs) to enable oligonucleotide detection in various body fluids including serum and urine (14,15). This method successfully demonstrated the use of HPs as a switch between closed and open status during an electrochemical reaction. The results provided significant improvements in both sensitivity and specificity. In the context of saliva diagnostics, low copy-numbers of RNA biomarkers in saliva demand highly sensitive sensors to detect signal above background noise. Herein, we propose a method that couples an enzymatic amplification process with a target-induced conformational change based on an HP probe. This HP comprises a loop component with a sequence complementary to the target and a stem component labeled with a reporter at one end. Without target binding, the proximity to the sensor surface creates steric hindrance (SH), which inhibits signal amplification by preventing mediator access to the probe reporter label. This built-in SH is removed after the bio-recognition component verifies the target specificity, making the reporter label accessible to the mediator-peroxidase conjugate and generating a current signal. Therefore, only the specific target can generate an amplified current, even if present in low copy numbers and in a complex mixture. The SH effect is controllable in this HP-based electrochemical sensor by optimizing probe design and the surface electrical field. Our selective amplification method suppresses nonspecific signal to background levels, overcoming key hurdles in developing point-of-care nucleic acid detection systems for salivary RNA markers and for other general use.

MATERIALS AND METHODS

Oligonucleotide probes and RNA

HPLC-purified oligonucleotides were custom synthesized (Operon Inc., Alabama, USA). The probe sequence allowed for the formation of a hairpin structure. The loop and half of the hairpin stem (3′-end) contained target recognition sequences, and HPs were labeled with biotin or biotin-(tetra-ethyleneglycol) TEG (the structure as shown above) on the 5′-end and with fluorescein on the 3′-end (detailed structures are shown in Supplementary materials I). The biotin label bound to streptavidin as an anchor to the chip surface, and the fluorescein label allowed for binding of the signal mediator. We investigated the following configurations of the 5′-linker from the probe to the chip surface: biotin link, biotin-TEG, biotin-9 thymidines (T9) and biotin-TEG-T9. Biotin-TEG had an extra spacer with mixed polarity based on triethylene glycol containing oxygen atoms connecting the biotin and the oligo chain. Different spacing designs may confer better accessibility of the biotin to the streptavidin, and could serve as an adjustable length linker for the SH effect. Interleukin-8 (IL-8) mRNA (NM_000584) (16) has been proposed as a salivary biomarker for oral cancer and was selected for detection. For the purpose of establishing the validity of the method, in vitro transcribed (IVT) IL-8 RNAs were used as a target for standard quantitative measurements. Details of IVT RNA generation are described in the Supplementary materials II section. Endogenous mRNAs were detected from clinical samples. For detecting endogenous IL-8 from saliva samples, a lysis process was carried out by mixing the saliva 1:1 with AVL viral lysis buffer (QIAGEN, California, USA) for 15 min at room temperature. Details of saliva collection and qPCR measurements are described in the Supplementary materials III-IX.

Surface preparation

The surface preparation of the gold electrochemical sensor was performed as follows (17,18):

Probe immobilization

The gold electrodes were precoated with a self-assembled monolayer of mercaptoundecanoic acid (MUDA), terminated by a carboxyl group (18). The gold surface was activated by a 4 μl mixture of 50% 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC, Biacore Inc., New Jersey, USA) and 50% N-hydroxysuccinimide (NHS) (Biacore) for 10 min. The sensors were rinsed with DI water (18.3 MΩ cm) and dried with nitrogen gas. A total of 4 μl of 5 mg/ml amine-PEO2-Biotin labeling reagent (Ez-Biotin) (Pierce Inc., Illinois, USA) was loaded to the gold surface, followed by rinsing and drying. Ethanolamine-HCl (1.0 M, pH 8.5, Biacore) was loaded for inactivation of the un-reacted EDC/NHS activated surface. Next, 0.5 mg/ml streptavidin (VWR Corp., California, USA) in PBS (pH 7.2, Invitrogen, California, USA) was incubated on the electrode for 10 min to produce streptavidin-coated electrodes. A total of 4 μl of 5′-biotinylated and 3′-fluorescein dual-labeled HP in Tris-HCl buffer (pH 7.5, Invitrogen, California, USA) was immobilized onto the electrodes for 30 min via the interactions between streptavidin on the surfaces and the biotin label on the probes. The surface density of the oligo probe achieved using this immobilization strategy was reported to be ∼3.4 × 1012 molecules/cm2 (19). Excessive HP was removed by a thorough rinse with DI water and dried with nitrogen gas.

Target hybridization

The surface was incubated for 5 min with the target-containing sample prepared in 6 × saline-sodium citrate buffer (6 × SSC, 0.09 M sodium citrate, with 0.9 M NaCl, pH 7.0, Invitrogen, California, USA) with the addition of 10 mM MgCl2 (Sigma Corp., Missouri, USA). During hybridization, a cyclic square-wave electric field was applied at 30 cycles of +200 mV for 1 s and −300 mV for 9 s. After hybridization, the electrodes were rinsed with DI water and dried with nitrogen gas.

Electrochemical detection

The electrochemical readout was performed using an electrochemical workstation according to the manufacturer's instructions. Briefly, anti-fluorescein-Horseradish peroxidase (HRP) (Roche, Indiana, USA) diluted in PBS with 0.5% casein blocking buffer (Blocker Casein in PBS, Pierce, pH 7.4) was added to the fluorescein label on the HP or the detector probes. Then, 3, 3′, 5, 5′ tetramethylbenzidine low activity (TMB/H2O2, Neogen Corp., Kentucky, USA) substrate was loaded, and amperometric detection was carried out by applying −200 mV potential versus gold to each electrode unit, followed by parallel signal read-out after 60 s of equilibration (17,18). The electrochemical sensor was a 16-unit gold array. For each unit, there were three electrodes including the working electrode (WE), counter electrode (CE) and reference electrode (RE) (18). The RE was determined to be +218 mV versus SCE by measuring cyclic voltammetric curves of 0.1 mM [Fe(CN)6]3-/4-. All electric potentials described in this report are in reference to the gold RE (+218 mV versus SCE). The advantages of this small electrode array are that the signal read-out of the 16 electrodes can be obtained simultaneously, and only 4 μl of sample solution is needed for detection. In our experiments, the electrochemical signal was the current generated by the redox of the HRP reporter enzyme. TMB continually regenerated reduced HRP via a 2-electron step, which amplified the current signal. The current was proportional to the surface concentration of hybridized target (18). All experiments were performed at room temperature.

RESULTS AND DISCUSSION

Hairpin-induced specific amplification

Detection of a specific target using the current approach was accomplished via a combination of sandwich-like signal amplification by HRP and TMB/H2O2 as well as selective hybridization by the HP design. This method was based on the SH effect: the surface near the HP inhibits the HRP conjugate binding to target-free probes. Therefore, the distance between the surface and reporter label on the probe was a key factor to the detection process. Upon target binding, the HP opened and the reporter was away from the surface, resulting in reduced restriction from the surface. Conjugated HRP bound to the fluorescein and generated current, constituting a signal-on process (Figure 1).
Figure 1.

Illustration of the specific signal amplification in HP electrochemical detection. When no target bound to the probe, the hairpin was closed. HRP could not form an effective complex and no signal was observed. After hybridization with target, the hairpin opened up and the HRP complex was formed. TMB regenerated the reactive HRP, thus amplifying the current signal.

Illustration of the specific signal amplification in HP electrochemical detection. When no target bound to the probe, the hairpin was closed. HRP could not form an effective complex and no signal was observed. After hybridization with target, the hairpin opened up and the HRP complex was formed. TMB regenerated the reactive HRP, thus amplifying the current signal. We compared four IL-8 specific HPs with and without 5′-linkers, which exhibited different levels of SH due to varying distances between the reporters and the electrode surface (Table 1). The length and flexibility of linkers were adjusted by the length of the TEG or an overhang spacer (T9) at the 5′-biotin labeled end. The longitudinal size of biotin-TEG was approximately 3 nm from molecular mechanics calculations (MM2) (20). Single stranded DNA was in a coiled state on the electrode when no force was applied. The coil was probably stretched to permit conjugate binding when the electrochemical detection was carried out at negative potential (21,22). Although the exact length of the T9 linker is not known, it was likely >3 nm under the negative potential, if duplex DNA is 9 bp × 0.28 nm/bp. The size of HRP is approximately 4 × 6.7 × 11.8 nm, according to protein crystal data (23).
Table 1.

Oligonucleotide sequences for IL-8 and S100A8

DesignationSequence (5′ to 3′)5′-label3′-label
IL-8 HPL0a,bGAG GGT TGC TCA GCC CTC TTC AAA AAC TTC TCC ACA ACC CTCBiotinFluorescein
IL-8 HPL1a,bGAG GGT TGC TCA GCC CTC TTC AAA AAC TTC TCC ACA ACC CTCBiotinTEGFluorescein
IL-8 HPL2a,bTTT TTT TTT GAG GGT TGC TCA GCC CTC TTC AAA AAC TTC TCC ACA ACC CTCBiotinFluorescein
IL-8 HPL3a,bTTT TTT TTT GAG GGT TGC TCA GCC CTC TTC AAA AAC TTC TCC ACA ACC CTCBiotinTEGFluorescein
IL-8 CPcTTT TTT TAT GAA TTC TCA GCC CTCBiotin
IL-8 DPcTTC AAA AAC TTC TCC ACA ACC CTCFluorescein
IL-8 HPa,bGAG GGT TGC TCA GCC CTC TTC AAA AAC TTC TCC ACA ACC CTCBiotinFluorescein
S100A8 HPa,bGTG TCC TCT TTG AAC CAG ACG TCT GCA CCC TTT TTC CTG ATA TAC TGA GGA CACBiotinFluorescein

aHairpin probe design was calculated by MFold free web server (27,28).

bThe target recognition sequences are listed in italic font. The stem sections of the hairpins are underlined.

cIL-8 CP is the capture probe with biotin label in dual probes detection. IL-8 DP is the detect probe with fluorescein label in dual probes detection.

Oligonucleotide sequences for IL-8 and S100A8 aHairpin probe design was calculated by MFold free web server (27,28). bThe target recognition sequences are listed in italic font. The stem sections of the hairpins are underlined. cIL-8 CP is the capture probe with biotin label in dual probes detection. IL-8 DP is the detect probe with fluorescein label in dual probes detection. Figure 2 shows the SH effects from different HP designs. For the probe with the longest linker (TEG−T9), the fluorescein was far away from the surface even when the hairpin was closed. The mediator complex was formed and SH effect was very small. Hybridization to the target only increased the distance of the HRP complex from the electrodes. Therefore, the signal decreased upon binding and recognition resulted in a very weak signal-off process (Figure 2). Signals with bound target were at similar levels for all four probes and the blank signal decreased with decreasing linker length. For the HP without a linker, the reporter was very close to the surface in the closed state. Therefore, the SH effect was very strong, and the lowest background was observed (SBR=8 : 1).
Figure 2.

Comparison of IL-8 HPs with different linker lengths. The HP sequences for IL-8 are listed in Table 1 as IL-8 HPL0, IL-8 HPL1, IL-8 HPL2 and IL-8 HPL3. The hairpin was closed in the blank control and opened after hybridization with RNA. The concentration of IL-8 RNA was 5 nM. The mean and SD of four experiments are shown. The configurations of the HPs with different linker length are shown schematically.

Comparison of IL-8 HPs with different linker lengths. The HP sequences for IL-8 are listed in Table 1 as IL-8 HPL0, IL-8 HPL1, IL-8 HPL2 and IL-8 HPL3. The hairpin was closed in the blank control and opened after hybridization with RNA. The concentration of IL-8 RNA was 5 nM. The mean and SD of four experiments are shown. The configurations of the HPs with different linker length are shown schematically.

Specificity

The specificity of HP without a linker was tested with cross-detection of two targets, and the results are shown in Figure 3. As a reference control, we used the mRNA for S100 calcium-binding protein A8 (S100A8 mRNA, NM_002964), which is highly expressed in saliva and has no oral cancer relevance. For each probe, a comparison between the complementary and noncomplementary IVT RNA target was carried out at concentrations of 5 nM and 500 nM for IL-8, and 7 nM and 700 nM for S100A8. Even noncomplementary targets that were over-expressed by 100-fold gave little signal increase for the IL-8- and S100A8-specific probes. Complementary target signals were >20 SDs (SDV) higher than the blank control. Both probes showed good RNA discrimination for 5 nM of IL-8 and 7 nM of S100A8.
Figure 3.

Cross-detection with two sets of IVT RNA applying HP: IL-8 and S100A8. (A) The amperometric signals for eight samples. (1)–(4) applied HPs for S100A8 and the targeting RNA were (1) 7 nM S100A8, (2) 500 nM IL-8, (3) 5 nM IL-8 and (4) buffer only, respectively. (5)–(8) used HPs for IL-8, and the targeting RNA were (5) 5 nM IL-8, (6) 700 nM S100A8, (7) 7 nM S100A8 and (8) buffer only, respectively. (B) Bar charts of the same eight samples in (A). The sequences for HPs are listed in Table 1 as IL-8 HP and S100A8 HP. Mean and SD of four individual experiments are shown.

Cross-detection with two sets of IVT RNA applying HP: IL-8 and S100A8. (A) The amperometric signals for eight samples. (1)–(4) applied HPs for S100A8 and the targeting RNA were (1) 7 nM S100A8, (2) 500 nM IL-8, (3) 5 nM IL-8 and (4) buffer only, respectively. (5)–(8) used HPs for IL-8, and the targeting RNA were (5) 5 nM IL-8, (6) 700 nM S100A8, (7) 7 nM S100A8 and (8) buffer only, respectively. (B) Bar charts of the same eight samples in (A). The sequences for HPs are listed in Table 1 as IL-8 HP and S100A8 HP. Mean and SD of four individual experiments are shown.

Control of SBR with hybridization efficiency

A major concern of the RNA sensor is the SBR. In the current HP designs, the SBR depended on the ratio of the numbers with an open or closed HP. Background levels were associated with the closed state when no specific target was bound, and signal was generated from the open state after target hybridization. These closed or open states during recognition required high efficiencies for both the intramolecular and intermolecular hybridization. To increase hybridization efficiency and optimize the SBR of this sensor, we modified the hairpin structure by changing both the stem and loop length. Three HPs with different stem–loop lengths were studied (sequences listed in Table 2). In all three probes, the 3′-end stem component was complementary to the target RNA, together with the loop. The probe with the short stem (6 bp) and the duplex (21 + 6 bp) had a high background and low signal (HPS3 in Figure 4). The probe with the longest stem (10 bp) and the duplex (10 + 31 bp) had the lowest blank signal and the highest signal for target (HPS1), indicating a better closed state when no target was bound and a better open state when hybridized with target. Complementary HP sequences included both the whole loop and half of the stem, providing lower free energy after target hybridization. Thus, once target was bound to the loop, even the very long stem could be opened due to its complementary sequence to the target. Since high hybridization efficiency benefits both the sensitivity and specificity, a good SBR was achieved. In contrast, it is difficult to determine the optimized probe sequence with the traditional linear probe (LP) (24). The long sequence was beneficial to the hybridization efficiency, but generates high background.
Table 2.

Oligonucleotide sequences for IL-8 HP with different stem-loop structures

DesignationSequence (5′ to 3′)Stem (bp)Loop (nt)Duplex (bp)
IL-8 HPS1a,b,cGAG GGT TGT GAT GAA TTC TCA GCC CTC TTC AAA AAC TTC TCC ACA ACC CTC103141
IL-8 HPS2a,b,cGAG GGT TGC TCA GCC CTC TTC AAA AAC TTC TCC ACA ACC CTC82634
IL-8 HPS3a,b,cGAG GGT CTC TTC AAA AAC TTC TCC ACA ACC CTC62127

aAll the probes were double labeled with 5′-biotin and 3′-fluorescein.

bHairpin probe design was calculated by MFold free web server (27,28).

cThe target recognition sequences are listed in italic font. The stem sections of the hairpins are underlined.

Figure 4.

Comparison of IL-8 HPs with different stem-loop designs. The sequences of three HPs are listed in Table 2 as IL-8 HPS1, IL-8 HPS2 and IL-8 HPS3. The hairpin was closed in the blank control and opened after hybridizing with the RNA. The underlined sequences were complementary to the target RNA. Sequences in italics indicate the stem and sequences in bold form the loop. HPS1: 10 bp in the stem and 41 bp in the duplex; HPS2: 8 bp in the stem and 34 bp in the duplex; HPS3: 6 bp in the stem and 27 bp in the duplex. The concentration of IL-8 RNA was 5 nM. The mean and SD of four experiments are shown.

Comparison of IL-8 HPs with different stem-loop designs. The sequences of three HPs are listed in Table 2 as IL-8 HPS1, IL-8 HPS2 and IL-8 HPS3. The hairpin was closed in the blank control and opened after hybridizing with the RNA. The underlined sequences were complementary to the target RNA. Sequences in italics indicate the stem and sequences in bold form the loop. HPS1: 10 bp in the stem and 41 bp in the duplex; HPS2: 8 bp in the stem and 34 bp in the duplex; HPS3: 6 bp in the stem and 27 bp in the duplex. The concentration of IL-8 RNA was 5 nM. The mean and SD of four experiments are shown. Oligonucleotide sequences for IL-8 HP with different stem-loop structures aAll the probes were double labeled with 5′-biotin and 3′-fluorescein. bHairpin probe design was calculated by MFold free web server (27,28). cThe target recognition sequences are listed in italic font. The stem sections of the hairpins are underlined.

Detection of spiked RNA in saliva

With proper HP design and cooperation from the SH effect, we can detect salivary RNA biomarker sequences over a wide dynamic range of target concentration. Figure 5 shows the relationship between the concentration and the current signal in buffer. For comparison, the original system with two LPs for each target was also examined, using previously published methods (24). Briefly, both probes were designed to be complementary to adjacent stretches of the target sequence. The ‘capture probe’ was immobilized on the electrode with a 5′-end biotin label. The ‘detector probe’ had a 3′-fluorescein label to bind with the anti-fluorescein-HRP. Our results show that good SBR for detecting IL-8 was obtained with HP, but poorer performance was seen with LP.
Figure 5.

Salivary IL-8 RNA detection by the LP and HP. LPs were IL-8 CP and IL-8 DP, and HP was IL-8 HP as listed in Table 1. Blank control signals were subtracted from the measured signals. Mean and SD of four experiments are shown. The data point of the 4 fM target for LP is not displayed, because its value was below that of the blank control.

Salivary IL-8 RNA detection by the LP and HP. LPs were IL-8 CP and IL-8 DP, and HP was IL-8 HP as listed in Table 1. Blank control signals were subtracted from the measured signals. Mean and SD of four experiments are shown. The data point of the 4 fM target for LP is not displayed, because its value was below that of the blank control. We defined the limit of detection (LOD) as the concentration with a signal of at least 2 SDV above the background level. According to the criteria, the LOD for HP was about 0.4 fM. For the LPs, the LOD of IL-8 was about 400 pM, which is about 10 000-fold higher than for the HP (Figure 5).

Detection of endogenous mRNA in saliva

We then proceeded to detect endogenous IL-8 mRNA in saliva samples. Changes in signal levels between different saliva samples were observed. IL-8 mRNA in eight clinical saliva samples were measured using the present optimized HP design. Since endogenous mRNA in saliva is combined with other macromolecules which mask detection, a lysis procedure was carried out before the electrochemical assay to release masked RNA. We observed a good correlation between the electrochemical signals for saliva samples and the qPCR results, as shown in Figure 6. Higher electrochemical signals were observed in the saliva samples containing a higher level of IL-8 mRNAs as determined by qPCR measurement. In addition to the PCR measurement, these results support the existence of mRNA in saliva. Our results also show that endogenous mRNA can be detected in saliva by an electrochemical method without PCR amplification, which meets the sensitivity requirement for point-of-care salivary diagnostics.
Figure 6.

Correlation between amperometric signals using HP and concentrations determined by qPCR of IL-8 mRNA for the same set of clinical saliva samples. The R2 for linear regression was 0.99.

Correlation between amperometric signals using HP and concentrations determined by qPCR of IL-8 mRNA for the same set of clinical saliva samples. The R2 for linear regression was 0.99. For detection of DNA oligonucleotides using various electrochemistry-associated methods, LOD in the fM range have been achieved. These methods include nano-particle-linked secondary probes (25), anodic stripping voltammetry of silver nanoparticles deposited in a multi-step reduction process (26) and electronic DNA sensors based on target-induced strand displacement mechanisms (15). mRNA has a longer sequence and more complicated secondary structure than oligos. To capture specific mRNA targets, a characteristic fragment of mRNA must be chosen carefully. Secondary mRNA structure may reduce hybridization between the capture probe and the target. In this study, we chose the mRNA fragment with minimal secondary structure, as calculated by the Mfold web server (27). Probe design also required thorough consideration of loop sequence, stem length and probe secondary structure. Considering the intrinsic 2D or 3D structure of the RNA, the following principles were applied for both linear and HP design: In summary, we developed an effective method for electrochemical detection of mRNA using HP with high sensitivity, high specificity and a large dynamic range (fM–nM in buffer system and spiked saliva). We also demonstrated that this technique works well for directly detecting endogenous mRNA without the need for PCR amplification. Affinity of probe to the target mRNA: mRNA secondary structure and secondary structure of probe sequences which are complimentary to the target RNA, including quadruplex and hairpin, were considered. Sequences without stable secondary structures were selected based on quadruplex and M-fold calculations. Formation of self-dimers and hybridization stability also were considered based on thermodynamic calculations. For optimal HP performance, half of the stem (3′-end), together with the loop was designed to be complementary to the target RNA. Since the 5′-end of the stem was immobilized onto the surface via biotin-streptavidin for all the HPs in this study, only the 3′-stem was free during the hybridization process. Sharing the 3′-end of the stem with the loop for duplex formation resulted in higher hybridization efficiency and more changes in the SH effect.

SUPPLEMENTARY DATA

Supplementary Data are available at NAR Online.
  27 in total

1.  Recognition of single nucleotide polymorphisms using scanning potential hairpin denaturation.

Authors:  Fang Wei; Chunlai Chen; Lin Zhai; Ning Zhang; Xin Sheng Zhao
Journal:  J Am Chem Soc       Date:  2005-04-20       Impact factor: 15.419

Review 2.  Nucleic acid based biosensors: the desires of the user.

Authors:  Sinuhe Hahn; Susanne Mergenthaler; Bernhard Zimmermann; Wolfgang Holzgreve
Journal:  Bioelectrochemistry       Date:  2005-10       Impact factor: 5.373

3.  Use of electrochemical DNA biosensors for rapid molecular identification of uropathogens in clinical urine specimens.

Authors:  Joseph C Liao; Mitra Mastali; Vincent Gau; Marc A Suchard; Annette K Møller; David A Bruckner; Jane T Babbitt; Yang Li; Jeffrey Gornbein; Elliot M Landaw; Edward R B McCabe; Bernard M Churchill; David A Haake
Journal:  J Clin Microbiol       Date:  2006-02       Impact factor: 5.948

Review 4.  The diagnostic uses of saliva.

Authors:  I D Mandel
Journal:  J Oral Pathol Med       Date:  1990-03       Impact factor: 4.253

5.  A unified view of polymer, dumbbell, and oligonucleotide DNA nearest-neighbor thermodynamics.

Authors:  J SantaLucia
Journal:  Proc Natl Acad Sci U S A       Date:  1998-02-17       Impact factor: 11.205

6.  Salivary transcriptome diagnostics for oral cancer detection.

Authors:  Yang Li; Maie A R St John; Xiaofeng Zhou; Yong Kim; Uttam Sinha; Richard C K Jordan; David Eisele; Elliot Abemayor; David Elashoff; No-Hee Park; David T Wong
Journal:  Clin Cancer Res       Date:  2004-12-15       Impact factor: 12.531

7.  Surface plasmon resonance spectroscopy and quartz crystal microbalance study of streptavidin film structure effects on biotinylated DNA assembly and target DNA hybridization.

Authors:  Xiaodi Su; Ying-Ju Wu; Rudolf Robelek; Wolfgang Knoll
Journal:  Langmuir       Date:  2005-01-04       Impact factor: 3.882

8.  Electrochemical detection of DNA hybridization using biometallization.

Authors:  Seongpil Hwang; Eunkyung Kim; Juhyoun Kwak
Journal:  Anal Chem       Date:  2005-01-15       Impact factor: 6.986

9.  Interleukin 6 and interleukin 8 as potential biomarkers for oral cavity and oropharyngeal squamous cell carcinoma.

Authors:  Maie A R St John; Yang Li; Xiaofeng Zhou; Paul Denny; Chih-Ming Ho; Carlo Montemagno; Wenyuan Shi; Fengxia Qi; Benjamin Wu; Uttam Sinha; Richard Jordan; Lawrence Wolinsky; No-Hee Park; Honghu Liu; Elliot Abemayor; David T W Wong
Journal:  Arch Otolaryngol Head Neck Surg       Date:  2004-08

Review 10.  Electrochemical molecular analysis without nucleic acid amplification.

Authors:  Vincent Gau; Shu-Ching Ma; Hua Wang; Joni Tsukuda; John Kibler; David A Haake
Journal:  Methods       Date:  2005-10-04       Impact factor: 3.608

View more
  14 in total

Review 1.  Salivary biomarkers for clinical applications.

Authors:  Lei Zhang; Hua Xiao; David T Wong
Journal:  Mol Diagn Ther       Date:  2009       Impact factor: 4.074

Review 2.  Clinical validity of saliva and novel technology for cancer detection.

Authors:  Karolina Elżbieta Kaczor-Urbanowicz; Fang Wei; Shannon Liu Rao; Jinseok Kim; Heebum Shin; Jordan Cheng; Michael Tu; David T W Wong; Yong Kim
Journal:  Biochim Biophys Acta Rev Cancer       Date:  2019-05-30       Impact factor: 10.680

3.  Quadratic isothermal amplification for the detection of microRNA.

Authors:  Ruixue Duan; Xiaolei Zuo; Shutao Wang; Xiyun Quan; Dongliang Chen; Zhifei Chen; Lei Jiang; Chunhai Fan; Fan Xia
Journal:  Nat Protoc       Date:  2014-02-13       Impact factor: 13.491

4.  Electrochemical DNA detection via exonuclease and target-catalyzed transformation of surface-bound probes.

Authors:  Kuangwen Hsieh; Yi Xiao; H Tom Soh
Journal:  Langmuir       Date:  2010-06-15       Impact factor: 3.882

Review 5.  Salivary extracellular noncoding RNA: emerging biomarkers for molecular diagnostics.

Authors:  David T W Wong
Journal:  Clin Ther       Date:  2015-03-18       Impact factor: 3.393

6.  A Microfluidic Cartridge System for Multiplexed Clinical Analysis.

Authors:  Walson Lawi; Chris Wiita; Steven T Snyder; Fang Wei; David Wong; Pak Kin Wong; Joseph C Liao; David Haake; Vincent Gau
Journal:  JALA Charlottesv Va       Date:  2009-12-01

Review 7.  DNA diagnostics: nanotechnology-enhanced electrochemical detection of nucleic acids.

Authors:  Fang Wei; Peter B Lillehoj; Chih-Ming Ho
Journal:  Pediatr Res       Date:  2010-05       Impact factor: 3.756

8.  Single bead-based electrochemical biosensor.

Authors:  Changchun Liu; Michael G Schrlau; Haim H Bau
Journal:  Biosens Bioelectron       Date:  2009-08-28       Impact factor: 10.618

9.  Serum creatinine detection by a conducting-polymer-based electrochemical sensor to identify allograft dysfunction.

Authors:  Fang Wei; Scott Cheng; Yael Korin; Elaine F Reed; David Gjertson; Chih-ming Ho; H Albin Gritsch; Jeffrey Veale
Journal:  Anal Chem       Date:  2012-08-24       Impact factor: 6.986

10.  Electrochemical sensor for multiplex biomarkers detection.

Authors:  Fang Wei; Prabhudas Patel; Wei Liao; Kishore Chaudhry; Lei Zhang; Martha Arellano-Garcia; Shen Hu; David Elashoff; Hui Zhou; Shilin Shukla; Franky Shah; Chih-Ming Ho; David T Wong
Journal:  Clin Cancer Res       Date:  2009-06-09       Impact factor: 12.531

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.