Effects of mechanical ventilation on the electrocardiogram in adults.

Jason Elinoff1, Daniel Talmor2, Balachundhar Subramaniam2, Dimitrios Karmpaliotis3, Ary L Goldberger4, Atul Malhotra5.   

Abstract

The effects of mechanical ventilation on the surface electrocardiogram (ECG) have not been systematically investigated and the anticipated changes such as rightward P and QRS axes shifts, reduced QRS voltage, and slow R-wave progression are not supported by definitive data. We sought to determine the effects of mechanical ventilation on the surface ECG in hemodynamically stable adults without active cardiopulmonary disease. Seventeen patients in good overall health who were undergoing elective outpatient surgery had serial ECGs done preoperatively, intraoperatively, and postoperatively. No clinically significant changes in QRS or P-wave axis were detected. R-wave progression was not altered and there were no significant differences in the QRS amplitudes pre-, intra-, or postoperatively in either the precordial or limb leads. The present study shows that hemodynamically stable patients without active cardiopulmonary disease undergoing elective surgery demonstrate relatively minor ECG changes from baseline despite the addition of positive pressure ventilation. Clinicians should not assume that substantial changes in P wave or QRS axis or amplitude in patients undergoing mechanical ventilation are due to the effects of positive pressure ventilation alone.

Entities:  

Mesh:

Year:  2008        PMID: 18478291      PMCID: PMC3955878          DOI: 10.1007/s00408-008-9094-6

Source DB:  PubMed          Journal:  Lung        ISSN: 0341-2040            Impact factor:   2.584


  17 in total

1.  Anasarca-mediated attenuation of the amplitude of electrocardiogram complexes: a description of a heretofore unrecognized phenomenon.

Authors:  J E Madias; R Bazaz; H Agarwal; M Win; L Medepalli
Journal:  J Am Coll Cardiol       Date:  2001-09       Impact factor: 24.094

2.  Electrocardiographic poor R wave progression. I: correlation with the Frank vectorcardiogram.

Authors:  M J Zema; P Kligfield
Journal:  J Electrocardiol       Date:  1979-01       Impact factor: 1.438

3.  Electrocardiographic prediction of hyperinflation in children.

Authors:  S S Krishnan; J Stewart; N Amin; R T Griffin; A J Dozer
Journal:  Am J Respir Crit Care Med       Date:  1997-12       Impact factor: 21.405

4.  Electrocardiogram changes during positive pressure breathing in rabbits.

Authors:  F Joulia; P Barthelemy; V Lafay; M C Zattara-Hartmann; Y Jammes
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1996

Review 5.  Heart-lung interactions: applications in the critically ill.

Authors:  H E Fessler
Journal:  Eur Respir J       Date:  1997-01       Impact factor: 16.671

6.  A specific ECG triad associated with congestive heart failure.

Authors:  A L Goldberger
Journal:  Pacing Clin Electrophysiol       Date:  1982-07       Impact factor: 1.976

7.  The effects of halothane and sevoflurane on QT dispersion.

Authors:  N Güler; M Bilge; B Eryonucu; I Kati; C B Demirel
Journal:  Acta Cardiol       Date:  1999-12       Impact factor: 1.718

8.  Diaphragm levels as determinants of P axis in restrictive vs obstructive pulmonary disease.

Authors:  N S Shah; S M Koller; M L Janower; D H Spodick
Journal:  Chest       Date:  1995-03       Impact factor: 9.410

9.  Clinical, laboratory, roentgenographic, and electrocardiographic findings in patients with acute pulmonary embolism and no pre-existing cardiac or pulmonary disease.

Authors:  P D Stein; M L Terrin; C A Hales; H I Palevsky; H A Saltzman; B T Thompson; J G Weg
Journal:  Chest       Date:  1991-09       Impact factor: 9.410

10.  Prolongation of the QT interval by enflurane, isoflurane, and halothane in humans.

Authors:  W T Schmeling; D C Warltier; D J McDonald; K E Madsen; J L Atlee; J P Kampine
Journal:  Anesth Analg       Date:  1991-02       Impact factor: 5.108

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.