Literature DB >> 18475004

Motion estimation for cardiac emission tomography by optical flow methods.

D R Gilland1, B A Mair, J G Parker.   

Abstract

This paper describes a new method for estimating the 3D, non-rigid object motion in a time sequence of images. The method is a generalization of a standard optical flow algorithm that is incorporated into a successive quadratic approximation framework. The method was evaluated for gated cardiac emission tomography using images obtained from a mathematical, 4D phantom and a physical, dynamic phantom. The results showed that the proposed method offers improved motion estimation accuracy relative to the standard optical flow method. Convergence of the proposed algorithm was evidenced with a monotonically decreasing objective function value with iteration. Practical application of the motion estimation method in cardiac emission tomography includes quantitative myocardial motion estimation and 4D, motion-compensated image reconstruction.

Mesh:

Year:  2008        PMID: 18475004      PMCID: PMC2424264          DOI: 10.1088/0031-9155/53/11/016

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  13 in total

Review 1.  A survey of medical image registration.

Authors:  J B Maintz; M A Viergever
Journal:  Med Image Anal       Date:  1998-03       Impact factor: 8.545

2.  Nonrigid registration using free-form deformations: application to breast MR images.

Authors:  D Rueckert; L I Sonoda; C Hayes; D L Hill; M O Leach; D J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  1999-08       Impact factor: 10.048

Review 3.  A review of cardiac image registration methods.

Authors:  Timo Mäkelä; Patrick Clarysse; Outi Sipilä; Nicoleta Pauna; Quoc Cuong Pham; Toivo Katila; Isabelle E Magnin
Journal:  IEEE Trans Med Imaging       Date:  2002-09       Impact factor: 10.048

4.  Spatiotemporal processing of gated cardiac SPECT images using deformable mesh modeling.

Authors:  Jovan G Brankov; Yongyi Yang; Miles N Wernick
Journal:  Med Phys       Date:  2005-09       Impact factor: 4.071

5.  Fully 4D motion-compensated reconstruction of cardiac SPECT images.

Authors:  Erwan Gravier; Yongyi Yang; Michael A King; Mingwu Jin
Journal:  Phys Med Biol       Date:  2006-08-30       Impact factor: 3.609

6.  Accelerated image reconstruction using ordered subsets of projection data.

Authors:  H M Hudson; R S Larkin
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

7.  Computation of 3-D velocity fields from 3-D cine CT images of a human heart.

Authors:  S M Song; R M Leahy
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

8.  Estimation of the Rigid-Body Motion from Three-Dimensional Images Using a Generalized Center-of-Mass Points Approach.

Authors:  B Feng; P P Bruyant; P H Pretorius; R D Beach; H C Gifford; J Dey; M Gennert; M A King
Journal:  IEEE Trans Nucl Sci       Date:  2006-10       Impact factor: 1.679

9.  Block-iterative techniques for fast 4D reconstruction using a priori motion models in gated cardiac SPECT.

Authors:  D S Lalush; B M Tsui
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

10.  A Monte Carlo program for the simulation of scintillation camera characteristics.

Authors:  M Ljungberg; S E Strand
Journal:  Comput Methods Programs Biomed       Date:  1989-08       Impact factor: 5.428

View more
  4 in total

1.  Deformable left-ventricle mesh model for motion-compensated filtering in cardiac gated SPECT.

Authors:  Thibault Marin; Jovan G Brankov
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

Review 2.  Motion correction options in PET/MRI.

Authors:  Ciprian Catana
Journal:  Semin Nucl Med       Date:  2015-05       Impact factor: 4.446

Review 3.  Motion Correction and Its Impact on Absolute Myocardial Blood Flow Measures with PET.

Authors:  Marina Piccinelli; John R Votaw; Ernest V Garcia
Journal:  Curr Cardiol Rep       Date:  2018-03-24       Impact factor: 2.931

Review 4.  Principles of Simultaneous PET/MR Imaging.

Authors:  Ciprian Catana
Journal:  Magn Reson Imaging Clin N Am       Date:  2017-05       Impact factor: 2.266

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.