Literature DB >> 18471819

On the mechanical stability of porous coated press fit titanium implants: a finite element study of a pushout test.

Benedikt Helgason1, Marco Viceconti, Tómas P Rúnarsson, Sigurour Brynjólfsson.   

Abstract

Pushout tests can be used to estimate the shear strength of the bone implant interface. Numerous such experimental studies have been published in the literature. Despite this researchers are still some way off with respect to the development of accurate numerical models to simulate implant stability. In the present work a specific experimental pushout study from the literature was simulated using two different bones implant interface models. The implant was a porous coated Ti-6Al-4V retrieved 4 weeks postoperatively from a dog model. The purpose was to find out which of the interface models could replicate the experimental results using physically meaningful input parameters. The results showed that a model based on partial bone ingrowth (ingrowth stability) is superior to an interface model based on friction and prestressing due to press fit (initial stability). Even though the present study is limited to a single experimental setup, the authors suggest that the presented methodology can be used to investigate implant stability from other experimental pushout models. This would eventually enhance the much needed understanding of the mechanical response of the bone implant interface and help to quantify how implant stability evolves with time.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18471819     DOI: 10.1016/j.jbiomech.2008.03.007

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  Interactive graph-cut segmentation for fast creation of finite element models from clinical ct data for hip fracture prediction.

Authors:  Yves Pauchard; Thomas Fitze; Diego Browarnik; Amiraslan Eskandari; Irene Pauchard; William Enns-Bray; Halldór Pálsson; Sigurdur Sigurdsson; Stephen J Ferguson; Tamara B Harris; Vilmundur Gudnason; Benedikt Helgason
Journal:  Comput Methods Biomech Biomed Engin       Date:  2016-05-10       Impact factor: 1.763

2.  Characterization of bone-implant fixation using modal analysis: application to a press-fit implant model.

Authors:  P Swider; G Guérin; Joergen Baas; Kjeld Søballe; Joan E Bechtold
Journal:  J Biomech       Date:  2009-05-22       Impact factor: 2.712

3.  The Effectiveness of Percutaneous Vertebroplasty Is Determined by the Patient-Specific Bone Condition and the Treatment Strategy.

Authors:  René P Widmer Soyka; Benedikt Helgason; Javad Hazrati Marangalou; Joop P van den Bergh; Bert van Rietbergen; Stephen J Ferguson
Journal:  PLoS One       Date:  2016-04-21       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.