Literature DB >> 18460824

Measurement of photoneutron dose produced by wedge filters of a high energy linac using polycarbonate films.

Seyed Mehdi Hashemi1, Bijan Hashemi-Malayeri, Gholamreza Raisali, Parvaneh Shokrani, Ali Akbar Sharafi, Falamarz Torkzadeh.   

Abstract

Radiotherapy represents the most widely spread technique to control and treat cancer. To increase the treatment efficiency, high energy linacs are used. However, applying high energy photon beams leads to a non-negligible dose of neutrons contaminating therapeutic beams. In addition, using conventional linacs necessitates applying wedge filters in some clinical conditions. However, there is not enough information on the effect of these filters on the photoneutrons produced. The aim of this study was to investigate the change of photoneutron dose equivalent due to the use of linac wedge filters. A high energy (18 MV) linear accelerator (Elekta SL 75/25) was studied. Polycarbonate films were used to measure the dose equivalent of photoneutrons. After electrochemical etching of the films, the neutron dose equivalent was calculated using Hp(10) factor, and its variation on the patient plane at 0, 5, 10, 50 and 100 cm from the center of the X-ray beam was determined. By increasing the distance from the center of the X-ray beam towards the periphery, the photoneutron dose equivalent decreased rapidly for the open and wedged fields. Increasing of the field size increased the photoneutron dose equivalent. The use of wedge filter increased the proportion of the neutron dose equivalent. The increase can be accounted for by the selective absorption of the high energy photons by the wedge filter.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18460824     DOI: 10.1269/jrr.07066

Source DB:  PubMed          Journal:  J Radiat Res        ISSN: 0449-3060            Impact factor:   2.724


  4 in total

Review 1.  A review on photoneutrons characteristics in radiation therapy with high-energy photon beams.

Authors:  Alireza Naseri; Asghar Mesbahi
Journal:  Rep Pract Oncol Radiother       Date:  2010-09-22

2.  Evaluating photoneutron dose equivalents for lung cancer using PMMA phantoms undergoing 15 MV IMRT.

Authors:  Hai-Bing Xu; An-Ding Dong; Mu-Tai Liu; Hsien-Chun Tseng; Chien-Yi Chen; Sung-Yi Tsai
Journal:  Technol Health Care       Date:  2022       Impact factor: 1.205

3.  Assessment of Neutron Contamination Originating from the Presence of Wedge and Block in Photon Beam Radiotherapy.

Authors:  M T Bahreyni Toossi; B Khajetash; M Ghorbani
Journal:  J Biomed Phys Eng       Date:  2018-03-01

4.  Photoneutron Dose Estimation in GRID Therapy Using an Anthropomorphic Phantom: A Monte Carlo Study.

Authors:  Nahid Chegeni; Amir Hossein Karimi; Iraj Jabbari; Shole Arvandi
Journal:  J Med Signals Sens       Date:  2018 Jul-Sep
  4 in total