Literature DB >> 18455045

The ventilation of multiple-bed hospital wards: review and analysis.

Clive B Beggs1, Kevin G Kerr, Catherine J Noakes, E Abigail Hathway, P Andrew Sleigh.   

Abstract

BACKGROUND: Although the merits of ventilating operating theatres and isolation rooms are well known, the clinical benefits derived from ventilating hospital wards and patient rooms are unclear. This is because relatively little research work has been done in the ventilation of these areas compared with that done in operating theatres and isolation rooms. Consequently, there is a paucity of good quality data from which to make important decisions regarding hospital infrastructure. This review evaluates the role of general ward ventilation to assess whether or not it affects the transmission of infection.
METHODS: A critical review was undertaken of guidelines in the United Kingdom and United States governing the design of ventilation systems for hospital wards and other multibed rooms. In addition, an analytical computational fluid dynamics (CFD) study was performed to evaluate the effectiveness of various ventilation strategies in removing airborne pathogens from ward spaces.
RESULTS: The CFD simulation showed the bioaerosol concentration in the study room to be substantially lower (2467 cfu/m(3)) when air was supplied and extracted through the ceiling compared with other simulated ventilations strategies, which achieved bioaerosol concentrations of 12487 and 10601 cfu/m(3), respectively.
CONCLUSIONS: There is a growing body of evidence that the aerial dispersion of some nosocomial pathogens can seed widespread environmental contamination, and that this may be contributing to the spread infection in hospital wards. Acinetobacter spp in particular appear to conform to this model, with numerous outbreaks attributed to aerial dissemination. This suggests that the clinical role of general ward ventilation may have been underestimated and that through improved ward ventilation, it may be possible to reduce environmental contamination and thus reduce nosocomial infection rates.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18455045     DOI: 10.1016/j.ajic.2007.07.012

Source DB:  PubMed          Journal:  Am J Infect Control        ISSN: 0196-6553            Impact factor:   2.918


  27 in total

1.  Role of two-way airflow owing to temperature difference in severe acute respiratory syndrome transmission: revisiting the largest nosocomial severe acute respiratory syndrome outbreak in Hong Kong.

Authors:  Chun Chen; Bin Zhao; Xudong Yang; Yuguo Li
Journal:  J R Soc Interface       Date:  2010-11-10       Impact factor: 4.118

Review 2.  Some aspects of the airborne transmission of infection.

Authors:  Raymond P Clark; Mervyn L de Calcina-Goff
Journal:  J R Soc Interface       Date:  2009-10-08       Impact factor: 4.118

3.  Effect of negative air ions on the potential for bacterial contamination of plastic medical equipment.

Authors:  Simon J Shepherd; Clive B Beggs; Caroline F Smith; Kevin G Kerr; Catherine J Noakes; P Andrew Sleigh
Journal:  BMC Infect Dis       Date:  2010-04-12       Impact factor: 3.090

4.  The effectiveness of an air cleaner in controlling droplet/aerosol particle dispersion emitted from a patient's mouth in the indoor environment of dental clinics.

Authors:  Chun Chen; Bin Zhao; Weilin Cui; Lei Dong; Na An; Xiangying Ouyang
Journal:  J R Soc Interface       Date:  2009-12-23       Impact factor: 4.118

5.  Analysis of indoor air pollutants checklist using environmetric technique for health risk assessment of sick building complaint in nonindustrial workplace.

Authors:  Ai Syazwan; B Mohd Rafee; Hafizan Juahir; Azf Azman; Am Nizar; Z Izwyn; K Syahidatussyakirah; Aa Muhaimin; Ma Syafiq Yunos; Ar Anita; J Muhamad Hanafiah; Ms Shaharuddin; A Mohd Ibthisham; I Mohd Hasmadi; Mn Mohamad Azhar; Hs Azizan; I Zulfadhli; J Othman; M Rozalini; Ft Kamarul
Journal:  Drug Healthc Patient Saf       Date:  2012-09-21

6.  Modelling levels of nitrous oxide exposure for healthcare professionals during EMONO usage.

Authors:  Marine Pichelin; Catherine Billoet; Georges Caillibotte
Journal:  Ann Occup Environ Med       Date:  2016-07-07

Review 7.  The risk of HCV infection among health-care workers and its association with extrahepatic manifestations (Review).

Authors:  Adriana Garozzo; Luca Falzone; Venerando Rapisarda; Andrea Marconi; Diana Cinà; Concettina Fenga; Demetrios A Spandidos; Massimo Libra
Journal:  Mol Med Rep       Date:  2017-03-24       Impact factor: 2.952

8.  Healthcare environments and spatial variability of healthcare associated infection risk: cross-sectional surveys.

Authors:  Jean Gaudart; Elaine Cloutman-Green; Serge Guillas; Nikki D'Arcy; John C Hartley; Vanya Gant; Nigel Klein
Journal:  PLoS One       Date:  2013-09-19       Impact factor: 3.240

9.  Viability of Pseudomonas aeruginosa in cough aerosols generated by persons with cystic fibrosis.

Authors:  Luke D Knibbs; Graham R Johnson; Timothy J Kidd; Joyce Cheney; Keith Grimwood; Jacqueline A Kattenbelt; Peter K O'Rourke; Kay A Ramsay; Peter D Sly; Claire E Wainwright; Michelle E Wood; Lidia Morawska; Scott C Bell
Journal:  Thorax       Date:  2014-04-17       Impact factor: 9.139

10.  A Survey of the quantity and type of biological aerosols in selected wards of a teaching hospital in Ghazvin.

Authors:  Akbar Eslami; Fatemeh Karimi; Zainab Karimi; Zahra Rajabi
Journal:  Electron Physician       Date:  2016-04-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.