Abstract

OBJECTIVE: To determine the accuracy of the ultrasonographic measurement of ulnar nerve to cubital tunnel area for diagnosis of ulnar neuropathy at the elbow.
DESIGN: Patients with confirmed ulnar neuropathy at the elbow and normative, healthy volunteers were evaluated with high-resolution ultrasound. The cross-sectional areas (CSAs) of the ulnar nerve and cubital tunnel were measured with the elbow extended and flexed, and results from the 2 groups were compared.
SETTING: Electromyography laboratory and radiology department of a tertiary care center. PARTICIPANTS: Twenty-seven patients with ulnar neuropathy at the elbow and 20 controls.
INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURE: The ratio of ulnar nerve to cubital tunnel CSA with the elbow flexed.
RESULTS: The ulnar nerve, with the elbow flexed, was larger in those with ulnar neuropathy at the elbow, and this group also had larger cubital tunnels than did controls. In those with ulnar neuropathy at the elbow, the ratio of the ulnar nerve to cubital tunnel was .31, and in the controls it was .32, which was not significantly different (P=.89).
CONCLUSIONS: The ratio of ulnar nerve to cubital tunnel did not differentiate those with ulnar neuropathy at the elbow from controls.

Entities:  

Mesh:

Year:  2008        PMID: 18452736     DOI: 10.1016/j.apmr.2007.10.024

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  4 in total

1.  Real-time visualization of ultrasonography guided cubital tunnel injection: a cadaveric study.

Authors:  Jae Min Kim; Hyun-Mi Oh; Min-Wook Kim
Journal:  Ann Rehabil Med       Date:  2012-08-27

2.  Estimation of ultrasound reference values for the ulnar nerve fascicular number and cross-sectional area in young males: A cross-sectional study.

Authors:  Mohamed Abdelmohsen Bedewi; Ahmed M M Yousef; Amr Adel Abd-Elghany; Mohamed Sherif El-Sharkawy; Ezzat M Awad
Journal:  Medicine (Baltimore)       Date:  2017-03       Impact factor: 1.889

3.  Diagnostic value of ultrasonography versus electrodiagnosis in ulnar neuropathy.

Authors:  Seyed Mansoor Rayegani; Seyed Ahmad Raeissadat; Elham Kargozar; Shahram Rahimi-Dehgolan; Elham Loni
Journal:  Med Devices (Auckl)       Date:  2019-02-22

4.  The feasibility of using high-resolution ultrasonography to assess ulnar nerve in patients with diabetes mellitus.

Authors:  Jun Chen; Chun-Lei Wang; Shan Wu; Shan He; Jun Ren
Journal:  J Ultrason       Date:  2017-09-29
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.