Literature DB >> 18448198

Prevalence of anti-legionella antibodies among Italian hospital workers.

P Borella1, A Bargellini, I Marchesi, S Rovesti, G Stancanelli, S Scaltriti, M Moro, M T Montagna, D Tatò, C Napoli, M Triassi, S Montegrosso, F Pennino, C M Zotti, S Ditommaso, M Giacomuzzi.   

Abstract

This study evaluated the prevalence of anti-legionella antibodies in workers at hospitals with a long-term history of legionella contamination. The hospitals are located in Milan and Turin, northern Italy, and in Naples and Bari, southern Italy. Antibody prevalence and titres of healthcare workers, medical and dental students and blood donors were assessed. In total 28.5% of subjects were antibody positive, most frequently to L. pneumophila serogroups 7-14. Major differences were observed in seroprevalence and type of legionella antibody in persons from different geographic areas. Healthcare workers had a significantly higher frequency of antibodies compared with blood donors in Milan (35.4 vs 15.9%, P<0.001), whereas in Naples both groups exhibited high antibody frequency (48.8 vs 44.0%) and had a higher proportion of antibodies to legionella serogroups 1-6. Dental workers had a higher seroprevalence than office staff in Bari, but not in Turin, where daily disinfecting procedures had been adopted to avoid contamination of dental unit water. No association was found between the presence of antibodies and the presence of risk factors for legionellosis, nor with the occurrence of pneumonia and/or flu-like symptoms. In conclusion, the presence of legionella antibodies may be associated with occupational exposure in the hospital environment, but there was no evidence of any association with disease.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18448198     DOI: 10.1016/j.jhin.2008.03.004

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  16 in total

Review 1.  A scoping review on bio-aerosols in healthcare and the dental environment.

Authors:  Charifa Zemouri; Hans de Soet; Wim Crielaard; Alexa Laheij
Journal:  PLoS One       Date:  2017-05-22       Impact factor: 3.240

Review 2.  Current and emerging Legionella diagnostics for laboratory and outbreak investigations.

Authors:  Jeffrey W Mercante; Jonas M Winchell
Journal:  Clin Microbiol Rev       Date:  2015-01       Impact factor: 26.132

3.  Microbial contamination of dental unit waterlines and effect on quality of indoor air.

Authors:  Duygu Göksay Kadaifciler; Aysin Cotuk
Journal:  Environ Monit Assess       Date:  2014-01-28       Impact factor: 2.513

4.  Are aerosol control devices effective in preventing the spread of dental aerosol?

Authors:  Elif Seher Böke; Ali Keleş; Cangül Keskin; Yeliz Tanrıverdi Çaycı; Tugba Turk
Journal:  PeerJ       Date:  2022-07-13       Impact factor: 3.061

5.  Legionella spp. and legionellosis in southeastern Italy: disease epidemiology and environmental surveillance in community and health care facilities.

Authors:  Christian Napoli; Fabrizio Fasano; Roberta Iatta; Giovanna Barbuti; Teresa Cuna; Maria Teresa Montagna
Journal:  BMC Public Health       Date:  2010-11-02       Impact factor: 3.295

6.  Hospital water and opportunities for infection prevention.

Authors:  Brooke K Decker; Tara N Palmore
Journal:  Curr Infect Dis Rep       Date:  2014-10       Impact factor: 3.725

7.  Impact of a risk management plan on Legionella contamination of dental unit water.

Authors:  Erica Leoni; Laura Dallolio; Francesca Stagni; Tiziana Sanna; Giovanni D'Alessandro; Gabriela Piana
Journal:  Int J Environ Res Public Health       Date:  2015-02-23       Impact factor: 3.390

8.  Legionella antibodies in a Danish hospital staff with known occupational exposure.

Authors:  M Rudbeck; S Viskum; K Mølbak; S A Uldum
Journal:  J Environ Public Health       Date:  2009-05-26

9.  Effect of different disinfection protocols on microbial and biofilm contamination of dental unit waterlines in community dental practices.

Authors:  Laura Dallolio; Amalia Scuderi; Maria S Rini; Sabrina Valente; Patrizia Farruggia; Maria A Bucci Sabattini; Gianandrea Pasquinelli; Anna Acacci; Greta Roncarati; Erica Leoni
Journal:  Int J Environ Res Public Health       Date:  2014-02-18       Impact factor: 3.390

10.  Legionella pneumophila Seropositivity-Associated Factors in Latvian Blood Donors.

Authors:  Olga Valciņa; Daina Pūle; Irina Lucenko; Dita Krastiņa; Žanete Šteingolde; Angelika Krūmiņa; Aivars Bērziņš
Journal:  Int J Environ Res Public Health       Date:  2015-12-22       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.