Literature DB >> 18442101

Effect of surface roughness, porosity, and a resorbable calcium phosphate coating on osseointegration of titanium in a minipig model.

Markus L R Schwarz1, Markus Kowarsch, Steffen Rose, Kristianna Becker, Tamara Lenz, Lutz Jani.   

Abstract

The aim of this study was to compare the osseointegration of four different implant surfaces in the Göttingen minipig femur model. They were prepared by glasspearlblasting (A), sandblasting (B) and titaniumplasma spraying (C and D). Surface D received additionally an electrochemically deposited layer of a resorbable calcium phosphate (CaP) layer, made mainly of brushite. Sample size was n = 20 per group. Implants were placed in the intertrochanteric and intercondylar sites of both femora. After 12 weeks, implant anchorage was measured by the pull-out test and histomorphometry measurements were carried out at the bone-implant interface. Implant anchorage was 0.7 +/- 0.3 MPa for surface A, 3.2 +/- 0.6 MPa for surface B, 6.5 +/- 1.5 MPa for surface C and 7.3 +/- 1.9 MPa for surface D. The differences between surfaces were statistically significant, with exception of C and D. The stiffness of the bone-implant interface showed no statistically significant difference between surfaces. After pull-out, surface A and B showed nearly no bone spots, while on surfaces C and D bone remains were found. Bone-implant contact was 1.9 +/- 1.1% for surface A, 10.5 +/- 3.6% for surface B, 22.4 +/- 4.5% for surface C and 48.8 +/- 4.5% for surface D. The differences were statistically significant. Implant location, intertrochanteric and intercondylar, did not affect the data. In this minipig model, rougher surfaces showed better osseointegration. After 12 weeks of healing, the resorbable CaP layer enhanced significantly the bone-implant contact but not the level of anchorage. The findings also suggest that the pull-out test should be critically evaluated to determine the shear strength between bone and porous surfaces. 2008 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 18442101     DOI: 10.1002/jbm.a.32000

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  17 in total

1.  Zinc and silica are active components to efficiently treat in vitro simulated eroded dentin.

Authors:  Raquel Osorio; Manuel Toledano-Osorio; Estrella Osorio; Fátima S Aguilera; Sussette Padilla-Mondéjar; Manuel Toledano
Journal:  Clin Oral Investig       Date:  2018-02-05       Impact factor: 3.573

2.  Surface contaminants inhibit osseointegration in a novel murine model.

Authors:  Lindsay A Bonsignore; Robb W Colbrunn; Joscelyn M Tatro; Patrick J Messerschmitt; Christopher J Hernandez; Victor M Goldberg; Matthew C Stewart; Edward M Greenfield
Journal:  Bone       Date:  2011-07-23       Impact factor: 4.398

3.  Influence of strut-size and cell-size variations on porous Ti6Al4V structures for load-bearing implants.

Authors:  Sushant Ciliveri; Amit Bandyopadhyay
Journal:  J Mech Behav Biomed Mater       Date:  2021-12-10

4.  Wettability and in-vitro study of titanium surface profiling prepared by electrolytic plasma processing.

Authors:  Wisanu Boonrawd; Kamal R Awad; Venu Varanasi; Efstathios I Meletis
Journal:  Surf Coat Technol       Date:  2021-03-31       Impact factor: 4.158

5.  A screening approach reveals the influence of mineral coating morphology on human mesenchymal stem cell differentiation.

Authors:  Siyoung Choi; William L Murphy
Journal:  Biotechnol J       Date:  2013-03-07       Impact factor: 4.677

6.  Calcium orthophosphate coatings, films and layers.

Authors:  Sergey V Dorozhkin
Journal:  Prog Biomater       Date:  2012-09-26

7.  Mechanical torque measurement in the proximal femur correlates to failure load and bone mineral density ex vivo.

Authors:  Stefan Grote; Tatjana Noeldeke; Michael Blauth; Wolf Mutschler; Dominik Bürklein
Journal:  Orthop Rev (Pavia)       Date:  2013-06-24

8.  Morphology, composition, and bioactivity of strontium-doped brushite coatings deposited on titanium implants via electrochemical deposition.

Authors:  Yongqiang Liang; Haoyan Li; Jiang Xu; Xin Li; Mengchun Qi; Min Hu
Journal:  Int J Mol Sci       Date:  2014-06-04       Impact factor: 5.923

9.  Three-Dimensional Analysis of the Contact Pattern between the Cortical Bone and Femoral Prosthesis after Cementless Total Hip Arthroplasty.

Authors:  Hiroshi Wada; Hajime Mishima; Hisashi Sugaya; Tomofumi Nishino; Masashi Yamazaki
Journal:  Adv Orthop       Date:  2016-01-10

10.  Analysis of the osseointegrative force of a hyperhydrophilic and nanostructured surface refinement for TPS surfaces in a gap healing model with the Göttingen minipig.

Authors:  Roland Seidling; Lars J Lehmann; Manuel Lingner; Eckhard Mauermann; Udo Obertacke; Markus L R Schwarz
Journal:  J Orthop Surg Res       Date:  2016-10-17       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.