Accuracy of guideline recommendations for two-dimensional quantification of the right ventricle by echocardiography.

Wyman W Lai1, Kimberlee Gauvreau, Ernesto S Rivera, Susan Saleeb, Andrew J Powell, Tal Geva.   

Abstract

BACKGROUND: The accuracy of the guidelines of the American Society of Echocardiography (ASE) for the two-dimensional (2D) quantitative assessment of right ventricular (RV) size and function has not been evaluated against MRI-derived RV volumes in patients with congenital heart disease and RV volume overload.
METHODS: Three groups of patients were studied: a normal RV group (Group I, n = 31), a repaired tetralogy of Fallot group (Group II, n = 33), and an unrepaired atrial septal defect and/or partially anomalous pulmonary venous connection group (Group III, n = 23). Recommended 2D linear and cross-sectional area measurements were made on clinical echocardiographic and MRI studies performed less than 6 months apart.
RESULTS: Most 2D RV parameters were smaller by echocardiography versus MRI. There was weak correlation between 2D RV measurements by echocardiography and MRI-derived RV volumes (Group I: r = 0.15-0.54, Group II: r = 0.33-0.61, Group III: r = 0.32-0.85), and only modest improvement when the same 2D measurements were performed by MRI (Group I: r = 0.37-0.61, Group II: r = 0.44-0.69, Group III: r = 0.28-0.74). The difference between 2D RV measurements by echocardiography and MRI-derived RV volumes was more pronounced in the RV volume overload groups.
CONCLUSIONS: The correlation between currently recommended 2D RV measurements by echocardiography and MRI-derived RV volumes was weak, and improved only modestly when MRI was used to make the same 2D measurements. Moreover, 2D echocardiographic assessment of the RV appears to be less accurate in patients with congenital heart disease and a dilated RV.

Entities:  

Mesh:

Year:  2008        PMID: 18438737     DOI: 10.1007/s10554-008-9314-4

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  25 in total

1.  Factors associated with impaired clinical status in long-term survivors of tetralogy of Fallot repair evaluated by magnetic resonance imaging.

Authors:  Tal Geva; Bryan M Sandweiss; Kimberlee Gauvreau; James E Lock; Andrew J Powell
Journal:  J Am Coll Cardiol       Date:  2004-03-17       Impact factor: 24.094

2.  Comparison of transthoracic three dimensional echocardiography with magnetic resonance imaging in the assessment of right ventricular volume and mass.

Authors:  M Vogel; M Gutberlet; S Dittrich; N Hosten; P E Lange
Journal:  Heart       Date:  1997-08       Impact factor: 5.994

3.  Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology.

Authors:  Roberto M Lang; Michelle Bierig; Richard B Devereux; Frank A Flachskampf; Elyse Foster; Patricia A Pellikka; Michael H Picard; Mary J Roman; James Seward; Jack S Shanewise; Scott D Solomon; Kirk T Spencer; Martin St John Sutton; William J Stewart
Journal:  J Am Soc Echocardiogr       Date:  2005-12       Impact factor: 5.251

Review 4.  The right ventricle: anatomy, physiology, and clinical importance.

Authors:  L J Dell'Italia
Journal:  Curr Probl Cardiol       Date:  1991-10       Impact factor: 5.200

5.  What is a "normal" right ventricle?

Authors:  Sylva Kovalova; Josef Necas; Jaroslav Vespalec
Journal:  Eur J Echocardiogr       Date:  2005-07-19

6.  Echocardiographic measurement of the normal adult right ventricle.

Authors:  R Foale; P Nihoyannopoulos; W McKenna; A Kleinebenne; A Nadazdin; E Rowland; G Smith; A Klienebenne
Journal:  Br Heart J       Date:  1986-07

7.  Reference right ventricular systolic and diastolic function normalized to age, gender and body surface area from steady-state free precession cardiovascular magnetic resonance.

Authors:  Alicia M Maceira; Sanjay K Prasad; Mohammed Khan; Dudley J Pennell
Journal:  Eur Heart J       Date:  2006-11-06       Impact factor: 29.983

8.  Echocardiographic Assessment of Right Ventricular Volume and Function.

Authors:  Leng Jiang; Robert A. Levine; Arthur E. Weyman
Journal:  Echocardiography       Date:  1997-03       Impact factor: 1.724

9.  Measurement of ventricular volumes in the dog by nuclear magnetic resonance imaging.

Authors:  W Markiewicz; U Sechtem; R Kirby; N Derugin; G C Caputo; C B Higgins
Journal:  J Am Coll Cardiol       Date:  1987-07       Impact factor: 24.094

10.  Normal values of right ventricular size and function by real-time 3-dimensional echocardiography: comparison with cardiac magnetic resonance imaging.

Authors:  Aasha S Gopal; Ebere O Chukwu; Chizor J Iwuchukwu; Alan S Katz; Rena S Toole; William Schapiro; Nathaniel Reichek
Journal:  J Am Soc Echocardiogr       Date:  2007-05       Impact factor: 5.251

View more
  59 in total

1.  Utility of transthoracic echocardiography to estimate severity of right ventricular dysfunction: an MRI comparison study.

Authors:  Suraj Kapa; Richard Elias; Heidi J Connolly; Imran S Syed; Samuel J Asirvatham
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-30       Impact factor: 2.357

Review 2.  Imaging the right ventricle--current state of the art.

Authors:  Luc L Mertens; Mark K Friedberg
Journal:  Nat Rev Cardiol       Date:  2010-08-10       Impact factor: 32.419

3.  Left ventricular torsional deformation in patients undergoing transcatheter closure of secundum atrial septal defect.

Authors:  Lili Dong; Feng Zhang; Xianhong Shu; Daxin Zhou; Lihua Guan; Cuizhen Pan; Haozhu Chen
Journal:  Int J Cardiovasc Imaging       Date:  2009-04-10       Impact factor: 2.357

4.  The right ventricle: knowing what is right.

Authors:  Björn Byström; Per Lindqvist; Michael Henein
Journal:  Int J Cardiovasc Imaging       Date:  2008-07-16       Impact factor: 2.357

Review 5.  The role of MRI and CT in congenital heart disease.

Authors:  Rajesh Krishnamurthy
Journal:  Pediatr Radiol       Date:  2009-04

Review 6.  Do we have two hearts? New insights in right ventricular function supported by myocardial imaging echocardiography.

Authors:  Antonio Vitarelli; Claudio Terzano
Journal:  Heart Fail Rev       Date:  2010-01       Impact factor: 4.214

7.  Repeatability of cardiac-MRI-measured right ventricular size and function in congenital heart disease.

Authors:  Rowan Walsh; Yishay Salem; Amee Shah; Wyman W Lai; James C Nielsen
Journal:  Pediatr Radiol       Date:  2011-03-25

8.  Early echocardiographic changes after percutaneous implantation of the Edwards SAPIEN transcatheter heart valve in the pulmonary position.

Authors:  Shahryar M Chowdhury; Ziyad M Hijazi; John Rhodes; Saibal Kar; Raj Makkar; Michael Mullen; Qi-Ling Cao; Lydia King; Jodi Akin; Girish Shirali
Journal:  Echocardiography       Date:  2013-02-22       Impact factor: 1.724

9.  An Intracardiac Soft Robotic Device for Augmentation of Blood Ejection from the Failing Right Ventricle.

Authors:  Markus A Horvath; Isaac Wamala; Eric Rytkin; Elizabeth Doyle; Christopher J Payne; Thomas Thalhofer; Ignacio Berra; Anna Solovyeva; Mossab Saeed; Sara Hendren; Ellen T Roche; Pedro J Del Nido; Conor J Walsh; Nikolay V Vasilyev
Journal:  Ann Biomed Eng       Date:  2017-05-16       Impact factor: 3.934

10.  How many versus how much: comprehensive haemodynamic evaluation of partial anomalous pulmonary venous connection by cardiac MRI.

Authors:  Neil Seller; Shi-Joon Yoo; Brian Grant; Lars Grosse-Wortmann
Journal:  Eur Radiol       Date:  2018-05-02       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.