Literature DB >> 18436903

Workarounds to barcode medication administration systems: their occurrences, causes, and threats to patient safety.

Ross Koppel1, Tosha Wetterneck, Joel Leon Telles, Ben-Tzion Karsh.   

Abstract

The authors develop a typology of clinicians' workarounds when using barcoded medication administration (BCMA) systems. Authors then identify the causes and possible consequences of each workaround. The BCMAs usually consist of handheld devices for scanning machine-readable barcodes on patients and medications. They also interface with electronic medication administration records. Ideally, BCMAs help confirm the five "rights" of medication administration: right patient, drug, dose, route, and time. While BCMAs are reported to reduce medication administration errors--the least likely medication error to be intercepted--these claims have not been clearly demonstrated. The authors studied BCMA use at five hospitals by: (1) observing and shadowing nurses using BCMAs at two hospitals, (2) interviewing staff and hospital leaders at five hospitals, (3) participating in BCMA staff meetings, (4) participating in one hospital's failure-mode-and-effects analyses, (5) analyzing BCMA override log data. The authors identified 15 types of workarounds, including, for example, affixing patient identification barcodes to computer carts, scanners, doorjambs, or nurses' belt rings; carrying several patients' prescanned medications on carts. The authors identified 31 types of causes of workarounds, such as unreadable medication barcodes (crinkled, smudged, torn, missing, covered by another label); malfunctioning scanners; unreadable or missing patient identification wristbands (chewed, soaked, missing); nonbarcoded medications; failing batteries; uncertain wireless connectivity; emergencies. The authors found nurses overrode BCMA alerts for 4.2% of patients charted and for 10.3% of medications charted. Possible consequences of the workarounds include wrong administration of medications, wrong doses, wrong times, and wrong formulations. Shortcomings in BCMAs' design, implementation, and workflow integration encourage workarounds. Integrating BCMAs within real-world clinical workflows requires attention to in situ use to ensure safety features' correct use.

Entities:  

Mesh:

Year:  2008        PMID: 18436903      PMCID: PMC2442264          DOI: 10.1197/jamia.M2616

Source DB:  PubMed          Journal:  J Am Med Inform Assoc        ISSN: 1067-5027            Impact factor:   4.497


  32 in total

1.  Using information technology to reduce rates of medication errors in hospitals.

Authors:  D W Bates
Journal:  BMJ       Date:  2000-03-18

2.  Using BCMA software to improve patient safety in Veterans Administration Medical Centers.

Authors:  Connie L Johnson; Russell A Carlson; Chris L Tucker; Candice Willette
Journal:  J Healthc Inf Manag       Date:  2002

3.  Scan your way to a comprehensive electronic medical record. Augment medication administration accuracy and increase documentation efficiency with bar coding technology.

Authors:  Geraldine A Coyle; Mary Heinen
Journal:  Nurs Manage       Date:  2002-12

4.  Improving patient safety by identifying side effects from introducing bar coding in medication administration.

Authors:  Emily S Patterson; Richard I Cook; Marta L Render
Journal:  J Am Med Inform Assoc       Date:  2002 Sep-Oct       Impact factor: 4.497

5.  Sensemaking of patient safety risks and hazards.

Authors:  James B Battles; Nancy M Dixon; Robert J Borotkanics; Barbara Rabin-Fastmen; Harold S Kaplan
Journal:  Health Serv Res       Date:  2006-08       Impact factor: 3.402

Review 6.  Using failure mode and effects analysis to plan implementation of smart i.v. pump technology.

Authors:  Tosha B Wetterneck; Kathleen A Skibinski; Tanita L Roberts; Susan M Kleppin; Mark E Schroeder; Myra Enloe; Steven S Rough; Ann Schoofs Hundt; Pascale Carayon
Journal:  Am J Health Syst Pharm       Date:  2006-08-15       Impact factor: 2.637

7.  Medication dispensing errors and potential adverse drug events before and after implementing bar code technology in the pharmacy.

Authors:  Eric G Poon; Jennifer L Cina; William Churchill; Nirali Patel; Erica Featherstone; Jeffrey M Rothschild; Carol A Keohane; Anthony D Whittemore; David W Bates; Tejal K Gandhi
Journal:  Ann Intern Med       Date:  2006-09-19       Impact factor: 25.391

8.  Medication errors and adverse drug events in an intensive care unit: direct observation approach for detection.

Authors:  Brian J Kopp; Brian L Erstad; Michelle E Allen; Andreas A Theodorou; Gail Priestley
Journal:  Crit Care Med       Date:  2006-02       Impact factor: 7.598

9.  Compliance with intended use of Bar Code Medication Administration in acute and long-term care: an observational study.

Authors:  Emily S Patterson; Michelle L Rogers; Roger J Chapman; Marta L Render
Journal:  Hum Factors       Date:  2006       Impact factor: 2.888

10.  Computerization can create safety hazards: a bar-coding near miss.

Authors:  Clement J McDonald
Journal:  Ann Intern Med       Date:  2006-04-04       Impact factor: 25.391

View more
  128 in total

1.  Modeling nurses' acceptance of bar coded medication administration technology at a pediatric hospital.

Authors:  Richard J Holden; Roger L Brown; Matthew C Scanlon; Ben-Tzion Karsh
Journal:  J Am Med Inform Assoc       Date:  2012-06-03       Impact factor: 4.497

2.  A multiple-drawer medication layout problem in automated dispensing cabinets.

Authors:  Jennifer A Pazour; Russell D Meller
Journal:  Health Care Manag Sci       Date:  2012-02-19

3.  Retail pharmacy staff perceptions of design strengths and weaknesses of electronic prescribing.

Authors:  Olufunmilola Odukoya; Michelle A Chui
Journal:  J Am Med Inform Assoc       Date:  2012-06-29       Impact factor: 4.497

4.  Mediation of adoption and use: a key strategy for mitigating unintended consequences of health IT implementation.

Authors:  Laurie L Novak; Shilo Anders; Cynthia S Gadd; Nancy M Lorenzi
Journal:  J Am Med Inform Assoc       Date:  2012-05-26       Impact factor: 4.497

5.  Exploring the translational impact of a home telemonitoring intervention using time-motion study.

Authors:  Rhonda Cady; Stanley Finkelstein; Bruce Lindgren; William Robiner; Ruth Lindquist; Arin VanWormer; Kathleen Harrington
Journal:  Telemed J E Health       Date:  2010-06       Impact factor: 3.536

6.  Value of human factors to medication and patient safety in the intensive care unit.

Authors:  Matthew C Scanlon; Ben-Tzion Karsh
Journal:  Crit Care Med       Date:  2010-06       Impact factor: 7.598

7.  A Pharmacy Blueprint for Electronic Medical Record Implementation Success.

Authors:  David S Bach; Kenneth R Risko; Frank K Zaran; Margo S Farber; Gregory J Polk
Journal:  Hosp Pharm       Date:  2015-06

8.  Medical home implementation: a sensemaking taxonomy of hard and soft best practices.

Authors:  Timothy Hoff
Journal:  Milbank Q       Date:  2013-12       Impact factor: 4.911

9.  Older adults' satisfaction with a medication dispensing device in home care.

Authors:  Blaine Reeder; George Demiris; Karen D Marek
Journal:  Inform Health Soc Care       Date:  2013-01-16       Impact factor: 2.439

10.  Organizational and technological correlates of nurses' trust in a smart intravenous pump.

Authors:  Enid Montague; Onur Asan; Erin Chiou
Journal:  Comput Inform Nurs       Date:  2013-03       Impact factor: 1.985

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.