Literature DB >> 18433859

Fracture frequency of all-ceramic crowns during dynamic loading in a chewing simulator using different loading and luting protocols.

S D Heintze1, A Cavalleri, G Zellweger, A Büchler, G Zappini.   

Abstract

OBJECTIVE: The purpose of this laboratory study was to compare the frequency of failures (complete fractures or partial cracks) of molar crowns made of two different all-ceramic materials during dynamic loading in a chewing simulator, as well as the fracture load when subjected to static loading, in relation to different dynamic loading and luting protocols.
METHODS: One hundred and forty-four molar crowns fabricated with IPS Empress or an experimental e.max Press material with high translucency (e.max Press Exp) were luted on CAD/CAM milled PMMA abutments (first lower molar, circular chamfer) either with Variolink or glass-ionomer cement (GIC). All crowns were loaded according to three different loading protocols (n=12 per group) and two force profiles (sinusoidal, rectangular) in a pneumatically driven chewing simulator with a steel stylus (Ø 8 mm) and they underwent simultaneous thermocycling (5 degrees C/55 degrees C). After each phase the crowns were evaluated with regard to fractures or cracks. After dynamic testing, the crowns that did not fail were subjected to compression loading until complete fracture in a universal testing machine (UTM). As control groups, unloaded crowns were also subjected to a UTM. Survival statistics with log-rank tests were applied for the results of the dynamic loading, while ANOVA with post hoc Tukey B was used for the fracture load results and two-way ANOVA was carried out for logarithmically transformed data. Weibull statistics were calculated for pooled fracture load data of the dynamically loaded and control groups.
RESULTS: In the 144 IPS Empress crowns, complete fractures were observed in 9 crowns and partial cracks in another 3 crowns. When the data was pooled, a statistically significant increase in fractures occurred when the sinusoidal force profile was applied compared to a rectangular force profile (log-rank, p<0.05). No fractures occurred in the e.max Press Exp crowns. The two-way ANOVA showed that the type of luting protocol used had the most significant effect on the fracture load of both materials. In conjunction with Empress, however, the luting material influenced the variability twice as much as in e.max Press Exp. There was no statistically significant difference in the fracture load of GIC-luted e.max Press Exp crowns and that of the Variolink luted Empress crowns. The force profile had a significant effect on the fracture load only of the Empress crowns but not of the e.max Press Exp crowns. Weibull statistics revealed a higher scattering of the data of dynamically loaded crowns compared to that of the control groups.
CONCLUSIONS: For testing all-ceramic materials, dynamic loading is indispensable to draw valid conclusions on clinical performance of all-ceramic molar crowns. A sinusoidal profile is advisable, while a gradual increase of the force amplitude does not significantly affect the results.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18433859     DOI: 10.1016/j.dental.2008.02.019

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  16 in total

1.  Mechanical performance of cement- and screw-retained all-ceramic single crowns on dental implants.

Authors:  Matthias Obermeier; Oliver Ristow; Kurt Erdelt; Florian Beuer
Journal:  Clin Oral Investig       Date:  2017-07-15       Impact factor: 3.573

2.  Polymer infiltrated ceramic network structures for resistance to fatigue fracture and wear.

Authors:  Haifa El Zhawi; Marina R Kaizer; Asima Chughtai; Rafael R Moraes; Yu Zhang
Journal:  Dent Mater       Date:  2016-08-29       Impact factor: 5.304

3.  Retention force of removable partial dentures with different double crowns.

Authors:  Christin Arnold; Jeremias Hey; Jürgen M Setz; Arne F Boeckler; Ramona Schweyen
Journal:  Clin Oral Investig       Date:  2017-11-03       Impact factor: 3.573

4.  Preparation Techniques Used to Make Single-Unit Crowns: Findings from The National Dental Practice-Based Research Network.

Authors:  Helena M Minyé; Gregg H Gilbert; Mark S Litaker; Rahma Mungia; Cyril Meyerowitz; David R Louis; Alan Slootsky; Valeria V Gordan; Michael S McCracken
Journal:  J Prosthodont       Date:  2018-11-08       Impact factor: 2.752

5.  Choice of cement for single-unit crowns: Findings from The National Dental Practice-Based Research Network.

Authors:  Nathaniel C Lawson; Mark S Litaker; Jack L Ferracane; Valeria V Gordan; Alan M Atlas; Tara Rios; Gregg H Gilbert; Michael S McCracken
Journal:  J Am Dent Assoc       Date:  2019-04-25       Impact factor: 3.634

6.  Effect of Surface Treatment and Cement on Fracture Load of Traditional Zirconia (3Y), Translucent Zirconia (5Y), and Lithium Disilicate Crowns.

Authors:  Nathaniel C Lawson; Carlos A Jurado; Chan-Te Huang; Geoffrey P Morris; John O Burgess; Perng-Ru Liu; Keith E Kinderknecht; Chee Paul Lin; Daniel A Givan
Journal:  J Prosthodont       Date:  2019-06-11       Impact factor: 2.752

7.  Effect of repeated ultrasonic instrumentation on single-unit crowns: a laboratory study.

Authors:  Florin Eggmann; Fabio Schiavone; Julia Amato; Annika Vahle; Roland Weiger; Nicola U Zitzmann
Journal:  Clin Oral Investig       Date:  2021-11-24       Impact factor: 3.573

8.  Monolithic and bi-layer CAD/CAM lithium-disilicate versus metal-ceramic fixed dental prostheses: comparison of fracture loads and failure modes after fatigue.

Authors:  Stefan Schultheis; Joerg R Strub; Thomas A Gerds; Petra C Guess
Journal:  Clin Oral Investig       Date:  2012-09-22       Impact factor: 3.573

9.  Fatigue resistance of CAD/CAM resin composite molar crowns.

Authors:  Fatma A Shembish; Hui Tong; Marina Kaizer; Malvin N Janal; Van P Thompson; Niek J Opdam; Yu Zhang
Journal:  Dent Mater       Date:  2016-01-08       Impact factor: 5.304

10.  Adhesive restoration of anterior endodontically treated teeth: influence of post length on fracture strength.

Authors:  Anaïs Ramírez-Sebastià; Tissiana Bortolotto; Maria Cattani-Lorente; Lluis Giner; Miguel Roig; Ivo Krejci
Journal:  Clin Oral Investig       Date:  2013-04-20       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.