Literature DB >> 18433828

Continuous monitoring of residual chlorine concentrations in response to controlled microbial intrusions in a laboratory-scale distribution system.

Damian E Helbling1, Jeanne M Vanbriesen.   

Abstract

The objective of this work was to evaluate the efficacy of deploying free chlorine sensors as surrogate monitors for bacterial contamination events in drinking water distribution systems. An on-line sensor integral with a laboratory-scale distribution system (LDS) was shown to respond rapidly to changes in residual free chlorine concentrations induced by injected loads of Escherichia coli suspended in a chlorine demand free buffer. The magnitude of the residual response was proportional to the injected cell concentration, the background free chlorine concentration in the LDS, and the contact time between the chlorine residual and the injected suspension, consistent with previous results in batch reactors. The magnitude of the residual response was predicted when kinetic models developed from reaction kinetics between free chlorine and E. coli determined in batch systems were evaluated at contact times determined from LDS hydraulics. This result highlights the suitability of using batch kinetics when modeling contaminant-induced chlorine decay in the distribution system. Modeling the propagation of chlorine demand signals generated by specific pathogens could aid in the assessment of distribution system vulnerability.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18433828     DOI: 10.1016/j.watres.2008.03.009

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  7 in total

1.  Evaluation of select sensors for real-time monitoring of Escherichia coli in water distribution systems.

Authors:  Syreeta L Miles; Ryan G Sinclair; Mark R Riley; Ian L Pepper
Journal:  Appl Environ Microbiol       Date:  2011-02-25       Impact factor: 4.792

2.  Field study on evaluation of the efficacy and usability of two disinfectants for drinking water treatment at small cattle breeders and dairy cattle farms.

Authors:  Asmaa N Mohammed
Journal:  Environ Monit Assess       Date:  2016-02-09       Impact factor: 2.513

Review 3.  Chlorination in the pandemic times: The current state of the art for monitoring chlorine residual in water and chlorine exposure in air.

Authors:  Tianling Li; Zhengguo Wang; Chenxu Wang; Jiayu Huang; Ming Zhou
Journal:  Sci Total Environ       Date:  2022-05-22       Impact factor: 10.753

4.  Effects of hydraulically disconnecting consumer pumps in an intermittent water supply.

Authors:  David D J Meyer; J Khari; Andrew J Whittle; Alexander H Slocum
Journal:  Water Res X       Date:  2021-06-18

5.  Resistance and inactivation kinetics of bacterial strains isolated from the non-chlorinated and chlorinated effluents of a WWTP.

Authors:  Sylvia Martínez-Hernández; Gabriela A Vázquez-Rodríguez; Rosa I Beltrán-Hernández; Francisco Prieto-García; José M Miranda-López; Carlos M Franco-Abuín; Alejandro Álvarez-Hernández; Ulises Iturbe; Claudia Coronel-Olivares
Journal:  Int J Environ Res Public Health       Date:  2013-08-06       Impact factor: 3.390

6.  Suitability of optical, physical and chemical measurements for detection of changes in bacterial drinking water quality.

Authors:  Jenni Ikonen; Tarja Pitkänen; Ilkka T Miettinen
Journal:  Int J Environ Res Public Health       Date:  2013-10-25       Impact factor: 3.390

7.  Long-Term Effects of Residual Chlorine on Pseudomonas aeruginosa in Simulated Drinking Water Fed With Low AOC Medium.

Authors:  Guannan Mao; Yuhao Song; Mark Bartlam; Yingying Wang
Journal:  Front Microbiol       Date:  2018-05-03       Impact factor: 5.640

  7 in total