Literature DB >> 18430449

High-speed digital scan converter for high-frequency ultrasound sector scanners.

Jin Ho Chang1, Jesse T Yen, K Kirk Shung.   

Abstract

This paper presents a high-speed digital scan converter (DSC) capable of providing more than 400 images per second, which is necessary to examine the activities of the mouse heart whose rate is 5-10 beats per second. To achieve the desired high-speed performance in cost-effective manner, the DSC developed adopts a linear interpolation algorithm in which two nearest samples to each object pixel of a monitor are selected and only angular interpolation is performed. Through computer simulation with the Field II program, its accuracy was investigated by comparing it to that of bilinear interpolation known as the best algorithm in terms of accuracy and processing speed. The simulation results show that the linear interpolation algorithm is capable of providing an acceptable image quality, which means that the difference of the root mean square error (RMSE) values of the linear and bilinear interpolation algorithms is below 1%, if the sample rate of the envelope samples is at least four times higher than the Nyquist rate for the baseband component of echo signals. The designed DSC was implemented with a single FPGA (Stratix EP1S60F1020C6, Altera Corporation, San Jose, CA) on a DSC board that is a part of a high-speed ultrasound imaging system developed. The temporal and spatial resolutions of the implemented DSC were evaluated by examining its maximum processing time with a time stamp indicating when an image is completely formed and wire phantom testing, respectively. The experimental results show that the implemented DSC is capable of providing images at the rate of 400 images per second with negligible processing error.

Entities:  

Mesh:

Year:  2008        PMID: 18430449      PMCID: PMC2570254          DOI: 10.1016/j.ultras.2008.03.001

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  11 in total

1.  A multirate scan conversion method

Authors: 
Journal:  Ultrasonics       Date:  2000-03       Impact factor: 2.890

2.  A study of the display pixel-based focusing method in ultrasound imaging.

Authors:  J S Hwang; T K Song
Journal:  Ultrason Imaging       Date:  2001-01       Impact factor: 1.578

Review 3.  The role of ultrasound in molecular imaging.

Authors:  H-D Liang; M J K Blomley
Journal:  Br J Radiol       Date:  2003       Impact factor: 3.039

4.  A novel envelope detector for high-frame rate, high-frequency ultrasound imaging.

Authors:  Jin Ho Chang; Jesse T Yen; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-09       Impact factor: 2.725

5.  Analysis of a scan conversion algorithm for a real-time sector scanner.

Authors:  M H Lee; J H Kim; S B Park
Journal:  IEEE Trans Med Imaging       Date:  1986       Impact factor: 10.048

6.  Principles and applications of ultrasound backscatter microscopy.

Authors:  F S Foster; G R Lockwood; L K Ryan; K A Harasiewicz; L Berube; A M Rauth
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1993       Impact factor: 2.725

7.  Real-time ultrasonic scan conversion via linear interpolation of oversampled vectors.

Authors:  W D Richard; R M Arthur
Journal:  Ultrason Imaging       Date:  1994-04       Impact factor: 1.578

8.  Ultrahigh frame rate retrospective ultrasound microimaging and blood flow visualization in mice in vivo.

Authors:  Emmanuel Chérin; Ross Williams; Andrew Needles; Godwin Liu; Christopher White; Allison S Brown; Yu-Qing Zhou; F Stuart Foster
Journal:  Ultrasound Med Biol       Date:  2006-05       Impact factor: 2.998

9.  Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications.

Authors:  Jonathan M Cannata; Timothy A Ritter; Wo-Hsing Chen; Ronald H Silverman; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-11       Impact factor: 2.725

10.  A high-frame rate high-frequency ultrasonic system for cardiac imaging in mice.

Authors:  Lei Sun; William D Richard; Jonathan M Cannata; Ching C Feng; Jeffrey A Johnson; Jesse T Yen; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-08       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.