Literature DB >> 18422990

'Bone map' for a safe placement of miniscrews generated by computed tomography.

L C Hernández1, G Montoto, M Puente Rodríguez, L Galbán, V Martínez.   

Abstract

OBJECTIVES: The aim of this manuscript is to provide a bone map that can be used as a general guide to determine the areas where miniscrews can be safely anchored.
MATERIALS AND METHODS: Twenty-one computed tomographies (CTs) of maxilla and mandible were taken by the imaging centre ORTOSCAN and two measures were taken: --first, the interradicular space in the mesiodistal plane of the maxillary and mandible teeth with slices taken at 3, 6, and 9 mm from the alveolar crest, in the palatine and vestibular slices, --second, the interradicular space in the vestibular-lingual direction.
RESULTS: We can see that the greatest amount of mesiodistal bone is between the first and second inferior molars on the vestibular side and between the second and first inferior molars on the lingual side, whereas the least amount of bone on the mesiodistal plane is between the inferior incisors on the vestibular side. To determine the length of the miniscrew, we must take into account that the greatest amount of vestibular-lingual bone is between the first and second inferior molar, whereas the least amount is between the central and lateral inferior incisors.
CONCLUSIONS: Mesiodistal values in vestibular are those that must be considered when inserting the microscrew so as not to damage the dental tissue. Mesiodistal measurements taken in palatal-lingual do not present problems when inserting microscrews.

Mesh:

Year:  2008        PMID: 18422990     DOI: 10.1111/j.1600-0501.2007.01507.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  6 in total

1.  Anatomical landmarks of mandibular interforaminal region related to dental implant placement with 3D CBCT: comparison between edentulous and dental mandibles.

Authors:  Elif Sener; Erinc Onem; Gulcan Coskun Akar; Figen Govsa; Mehmet Asim Ozer; Yelda Pinar; Ali Mert; B Guniz Baksi Sen
Journal:  Surg Radiol Anat       Date:  2017-11-09       Impact factor: 1.246

2.  "Safe zones" for miniscrew implant placement in different dentoskeletal patterns.

Authors:  Pajongjit Chaimanee; Boonsiva Suzuki; Eduardo Yugo Suzuki
Journal:  Angle Orthod       Date:  2011-01-24       Impact factor: 2.079

3.  Accuracy of a cone beam computed tomography-guided surgical stent for orthodontic mini-implant placement.

Authors:  Jae-Jung Yu; Gyu-Tae Kim; Yong-Suk Choi; Eui-Hwan Hwang; Janghyun Paek; Seong-Hun Kim; John C Huang
Journal:  Angle Orthod       Date:  2011-08-29       Impact factor: 2.079

4.  Root contact during drilling for microimplant placement. Affect of surgery site and operator expertise.

Authors:  U-Hyeong Cho; Wonjae Yu; Hee-Moon Kyung
Journal:  Angle Orthod       Date:  2010-01       Impact factor: 2.079

5.  Assessing the amount of interdental bone in posterior areas of the mandible for placing orthodontic mini-implants.

Authors:  Nasrin Esfahanizadeh; Damoun Shahraki; Hamidreza Daneshparvar; Ahmad Reza Talaei Pour; Mohammad Ali Saghiri; Ahmad Sheibaninia; Shadab Rashtak
Journal:  J Dent (Tehran)       Date:  2013-05

6.  3D mapping of safe and danger zones in the maxilla and mandible for the placement of intermaxillary fixation screws.

Authors:  Kathiravan Purmal; Mohammad Khursheed Alam; Abdullah Pohchi; Noor Hayati Abdul Razak
Journal:  PLoS One       Date:  2013-12-19       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.