Literature DB >> 18420868

Effects of a suction laryngoscope in a model with simulated severe airway hemorrhage.

Thomas Mitterlechner1, Nicolas Nerbl, Holger Herff, Peter Paal, Martin Moritz, Frank Kloss, Karl H Lindner, Volker Wenzel.   

Abstract

In severe airway hemorrhage, simultaneous suction and laryngoscopy may render intubation difficult. We built a suction laryngoscope that consists of an adjustable stainless steel-guide tube fixed at the lingual surface of a standard Macintosh laryngoscope blade. Via this steel-guide tube, a large suction catheter can be inserted and positioned exactly to suction pharyngeal blood or vomitus, rendering simultaneous suctioning and laryngoscopy possible. In contrast to previous suction laryngoscopes, our suction catheter has a large lumen, which enables fast suctioning and exact placement by adjusting the steel-guide tube. To assess whether our suction laryngoscope could provide better intubation conditions in comparison to a standard Macintosh laryngoscope in a bleeding airway scenario, 44 medical students intubated a manikin with severe simulated airway hemorrhage using our suction laryngoscope and a standard Macintosh laryngoscope in random order. There was no significant difference in time needed for intubation when using the suction versus the Macintosh laryngoscope (mean +/- SD: 43 +/- 13 vs 52 +/- 31 s; P = 0.07), but the number of esophageal intubations was significantly lower when using the suction laryngoscope [6 of 44 (13.6%) vs 19 of 44 (43.2%); P = 0.004]. In conclusion, when compared with a standard Macintosh laryngoscope, using a suction laryngoscope did not result in more rapid intubation, but significantly decreased the likelihood of esophageal intubations.

Entities:  

Mesh:

Year:  2008        PMID: 18420868     DOI: 10.1213/ane.0b013e31816f207a

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  4 in total

1.  Three-day tracheal intubation manikin training for novice doctors using Macintosh laryngoscope, McGRATH MAC videolaryngoscope and Pentax AirwayScope.

Authors:  Yuryo Murakami; Ryusuke Ueki; Miyuki Niki; Munetaka Hirose; Noriko Shimode
Journal:  Medicine (Baltimore)       Date:  2021-01-29       Impact factor: 1.817

2.  Comparing suction rates of novel DuCanto catheter against Yankauer and standard suction catheter using liquids of different viscosity-a technical simulation.

Authors:  Simon-Richard Finke; Daniel C Schroeder; Hannes Ecker; Bernd W Böttiger; Holger Herff; Wolfgang A Wetsch
Journal:  BMC Anesthesiol       Date:  2022-09-10       Impact factor: 2.376

3.  Evaluation of Karl Storz CMAC Tip™ device versus traditional airway suction in a cadaver model.

Authors:  Demis N Lipe; Randi Lindstrom; Dustin Tauferner; Christopher Mitchell; Peter Moffett
Journal:  West J Emerg Med       Date:  2014-07

4.  Comparison of the novel VieScope with conventional and video laryngoscope in a difficult airway scenario - a randomized, controlled simulation trial.

Authors:  Hannes Ecker; Simone Kolvenbach; Sebastian Stranz; Holger Herff; Wolfgang A Wetsch
Journal:  BMC Emerg Med       Date:  2021-07-30