Acoustic emissions during 3.1 MHz ultrasound bulk ablation in vitro.

T Douglas Mast1, Vasant A Salgaonkar, Chandrapriya Karunakaran, John A Besse, Saurabh Datta, Christy K Holland.   

Abstract

Acoustic emissions associated with cavitation and other bubble activity have previously been observed during ultrasound (US) ablation experiments. Because detectable bubble activity may be related to temperature, tissue state and sonication characteristics, these acoustic emissions are potentially useful for monitoring and control of US ablation. To investigate these relationships, US ablation experiments were performed with simultaneous measurements of acoustic emissions, tissue echogenicity and tissue temperature on fresh bovine liver. Ex vivo tissue was exposed to 0.9-3.3-s bursts of unfocused, continuous-wave, 3.10-MHz US from a miniaturized 32-element array, which performed B-scan imaging with the same piezoelectric elements during brief quiescent periods. Exposures used pressure amplitudes of 0.8-1.4 MPa for exposure times of 6-20 min, sufficient to achieve significant thermal coagulation in all cases. Acoustic emissions received by a 1-MHz, unfocused passive cavitation detector, beamformed A-line signals acquired by the array, and tissue temperature detected by a needle thermocouple were sampled 0.3-1.1 times per second. Tissue echogenicity was quantified by the backscattered echo energy from a fixed region-of-interest within the treated zone. Acoustic emission levels were quantified from the spectra of signals measured by the passive cavitation detector, including subharmonic signal components at 1.55 MHz, broadband signal components within the band 0.3-1.1 MHz and low-frequency components within the band 10-30 kHz. Tissue ablation rates, defined as the thermally ablated volumes per unit time, were assessed by quantitative analysis of digitally imaged, macroscopic tissue sections. Correlation analysis was performed among the averaged and time-dependent acoustic emissions in each band considered, B-mode tissue echogenicity, tissue temperature and ablation rate. Ablation rate correlated significantly with broadband and low-frequency emissions, but was uncorrelated with subharmonic emissions. Subharmonic emissions were found to depend strongly on temperature in a nonlinear manner, with significant emissions occurring within different temperature ranges for each sonication amplitude. These results suggest potential roles for passive detection of acoustic emissions in guidance and control of bulk US ablation treatments.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18420337      PMCID: PMC3845361          DOI: 10.1016/j.ultrasmedbio.2008.02.007

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  31 in total

1.  Sound scattering and localized heat deposition of pulse-driven microbubbles

Authors: 
Journal:  J Acoust Soc Am       Date:  2000-06       Impact factor: 1.840

2.  Modeling of high-intensity focused ultrasound-induced lesions in the presence of cavitation bubbles

Authors: 
Journal:  J Acoust Soc Am       Date:  2000-07       Impact factor: 1.840

3.  Interstitial ultrasound heating applicator for MR-guided thermal therapy.

Authors:  R Chopra; C Luginbuhl; A J Weymouth; F S Foster; M J Bronskill
Journal:  Phys Med Biol       Date:  2001-12       Impact factor: 3.609

4.  Bubble dynamics and size distributions during focused ultrasound insonation.

Authors:  Xinmai Yang; Ronald A Roy; R Glynn Holt
Journal:  J Acoust Soc Am       Date:  2004-12       Impact factor: 1.840

5.  Ultrasound applicators for interstitial thermal coagulation.

Authors:  C J Diederich; W H Nau; P R Stauffer
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1999       Impact factor: 2.725

6.  The intensity dependence of the site of maximal energy deposition in focused ultrasound surgery.

Authors:  N A Watkin; G R ter Haar; I Rivens
Journal:  Ultrasound Med Biol       Date:  1996       Impact factor: 2.998

7.  Growth of air bubbles in tissue by rectified diffusion.

Authors:  L A Crum; G M Hansen
Journal:  Phys Med Biol       Date:  1982-03       Impact factor: 3.609

8.  Evidence for ultrasonically induced cavitation in vivo.

Authors:  G R ter Haar; S Daniels
Journal:  Phys Med Biol       Date:  1981-11       Impact factor: 3.609

9.  Use of a microbubble agent to increase the effects of high intensity focused ultrasound on liver tissue.

Authors:  Yukio Kaneko; Toshiyuki Maruyama; Kenji Takegami; Toshiaki Watanabe; Hiroshi Mitsui; Kazuyuki Hanajiri; Hirokazu Nagawa; Yoichiro Matsumoto
Journal:  Eur Radiol       Date:  2005-03-01       Impact factor: 5.315

10.  MRI-guided gas bubble enhanced ultrasound heating in in vivo rabbit thigh.

Authors:  S D Sokka; R King; K Hynynen
Journal:  Phys Med Biol       Date:  2003-01-21       Impact factor: 3.609

View more
  20 in total

1.  Passive imaging with pulsed ultrasound insonations.

Authors:  Kevin J Haworth; T Douglas Mast; Kirthi Radhakrishnan; Mark T Burgess; Jonathan A Kopechek; Shao-Ling Huang; David D McPherson; Christy K Holland
Journal:  J Acoust Soc Am       Date:  2012-07       Impact factor: 1.840

2.  Methods to calibrate the absolute receive sensitivity of single-element, focused transducers.

Authors:  Kyle T Rich; T Douglas Mast
Journal:  J Acoust Soc Am       Date:  2015-09       Impact factor: 1.840

3.  Magnetic resonance imaging of boiling induced by high intensity focused ultrasound.

Authors:  Tatiana D Khokhlova; Michael S Canney; Donghoon Lee; Kenneth I Marro; Lawrence A Crum; Vera A Khokhlova; Michael R Bailey
Journal:  J Acoust Soc Am       Date:  2009-04       Impact factor: 1.840

4.  Integrated ultrasound and magnetic resonance imaging for simultaneous temperature and cavitation monitoring during focused ultrasound therapies.

Authors:  Costas D Arvanitis; Nathan McDannold
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

5.  Passive cavitation imaging with ultrasound arrays.

Authors:  Vasant A Salgaonkar; Saurabh Datta; Christy K Holland; T Douglas Mast
Journal:  J Acoust Soc Am       Date:  2009-12       Impact factor: 1.840

Review 6.  Imaging-based internal body temperature measurements: The journal Temperature toolbox.

Authors:  Juho Raiko; Kalle Koskensalo; Teija Sainio
Journal:  Temperature (Austin)       Date:  2020-05-29

7.  Characterization of cavitation-radiated acoustic power using diffraction correction.

Authors:  Kyle T Rich; Christy K Holland; Marepalli B Rao; T Douglas Mast
Journal:  J Acoust Soc Am       Date:  2018-12       Impact factor: 1.840

Review 8.  Thermometry and ablation monitoring with ultrasound.

Authors:  Matthew A Lewis; Robert M Staruch; Rajiv Chopra
Journal:  Int J Hyperthermia       Date:  2015-03-10       Impact factor: 3.914

9.  Spatial specificity and sensitivity of passive cavitation imaging for monitoring high-intensity focused ultrasound thermal ablation in ex vivo bovine liver.

Authors:  Kevin Haworth; Vasant A Salgaonkar; Nicholas M Corregan; Christy K Holland; T D Mast
Journal:  Proc Meet Acoust       Date:  2013-06-02

10.  Noninvasive determination of in situ heating rate using kHz acoustic emissions and focused ultrasound.

Authors:  Ajay Anand; Peter J Kaczkowski
Journal:  Ultrasound Med Biol       Date:  2009-08-21       Impact factor: 2.998

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.