The effect of continuous subcutaneous glucose monitoring (CGMS) versus intermittent whole blood finger-stick glucose monitoring (SBGM) on hemoglobin A1c (HBA1c) levels in Type I diabetic patients: a systematic review.

V T Chetty1, A Almulla, A Odueyungbo, L Thabane.   

Abstract

BACKGROUND AND
PURPOSE: Continuous glucose monitoring (CGMS) is a relatively new technology that measures interstitial glucose every 5 min for 72 h. The resulting profile provides a more comprehensive measure of glycemic excursions than intermittent self-blood finger-stick glucose monitoring (SBGM) and thus could potentially improve diabetes control. We performed a meta-analysis of randomized controlled trials comparing CGMS and SBGM in Type 1 diabetic patients. Our aim was to determine whether CGMS leads to better hemoglobin A1c (HBA1c) levels, a marker of long-term vascular risk.
METHODS: Randomized controlled trials comparing CGMS and SBGM in Type 1 diabetic patients were identified using both manual and electronic searches of the literature in MEDLINE, EMBASE, PUBMED and Cochrane Central Registry of Controlled Trials from 1996 to March 2007. Relevant studies were independently selected by two reviewers, who also extracted data on study design, quality and effect on HBA1c levels. Data from all trials were pooled using a random effects model.
RESULTS: Seven studies with a total of 335 patients fulfilled the inclusion criteria. Five studies were confined to the pediatric population (age<18 years). Study duration varied from 12 to 24 weeks. Compared with SBGM, CGMS was associated with a non-significant reduction in HBA1c (0.22%; 95% CI: -0.439% to 0.004%, p=0.055).
CONCLUSIONS: There is insufficient evidence to support the notion that CGMS provides a superior benefit over SBGM in terms of HBA1c reduction. There was some indication of improved detection of asymptomatic nocturnal hypoglycemia in the CGMS group.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18417243     DOI: 10.1016/j.diabres.2008.02.014

Source DB:  PubMed          Journal:  Diabetes Res Clin Pract        ISSN: 0168-8227            Impact factor:   5.602


  22 in total

Review 1.  Efficacy of continuous glucose monitoring in improving glycemic control and reducing hypoglycemia: a systematic review and meta-analysis of randomized trials.

Authors:  Gunjan Y Gandhi; Michelle Kovalaske; Yogish Kudva; Kristin Walsh; Mohamed B Elamin; Melody Beers; Cathy Coyle; Melissa Goalen; Mohammad Safwan Murad; Patricia J Erwin; Joshua Corpus; Victor M Montori; M Hassan Murad
Journal:  J Diabetes Sci Technol       Date:  2011-07-01

2.  The correlation of hemoglobin A1c to blood glucose.

Authors:  Ken Sikaris
Journal:  J Diabetes Sci Technol       Date:  2009-05-01

Review 3.  Evidence-informed clinical practice recommendations for treatment of type 1 diabetes complicated by problematic hypoglycemia.

Authors:  Pratik Choudhary; Michael R Rickels; Peter A Senior; Marie-Christine Vantyghem; Paola Maffi; Thomas W Kay; Bart Keymeulen; Nobuya Inagaki; Frantisek Saudek; Roger Lehmann; Bernhard J Hering
Journal:  Diabetes Care       Date:  2015-06       Impact factor: 19.112

Review 4.  Continuous glucose monitoring in insulin-treated patients in non-ICU settings.

Authors:  Ana Maria Gomez; Guillermo E Umpierrez
Journal:  J Diabetes Sci Technol       Date:  2014-08-13

5.  Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus.

Authors:  David B Sacks; Mark Arnold; George L Bakris; David E Bruns; Andrea Rita Horvath; M Sue Kirkman; Ake Lernmark; Boyd E Metzger; David M Nathan
Journal:  Diabetes Care       Date:  2011-06       Impact factor: 19.112

Review 6.  Exercise and glucose metabolism in persons with diabetes mellitus: perspectives on the role for continuous glucose monitoring.

Authors:  Michael Riddell; Bruce A Perkins
Journal:  J Diabetes Sci Technol       Date:  2009-07-01

Review 7.  Comparative analysis of the efficacy of continuous glucose monitoring and self-monitoring of blood glucose in type 1 diabetes mellitus.

Authors:  Baraka Floyd; Prakash Chandra; Stephanie Hall; Christopher Phillips; Ernest Alema-Mensah; Gregory Strayhorn; Elizabeth O Ofili; Guillermo E Umpierrez
Journal:  J Diabetes Sci Technol       Date:  2012-09-01

Review 8.  Continuous glucose monitoring systems for type 1 diabetes mellitus.

Authors:  Miranda Langendam; Yoeri M Luijf; Lotty Hooft; J Hans Devries; Aart H Mudde; Rob J P M Scholten
Journal:  Cochrane Database Syst Rev       Date:  2012-01-18

9.  The role of continuous glucose monitoring in the care of children with type 1 diabetes.

Authors:  Noelle S Larson; Jordan E Pinsker
Journal:  Int J Pediatr Endocrinol       Date:  2013-03-26

10.  Correlations of glucose levels in interstitial fluid estimated by continuous glucose monitoring systems and venous plasma.

Authors:  Byung-Joon Kim
Journal:  Korean Diabetes J       Date:  2010-12-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.