Literature DB >> 18403628

Direct MR arthrography at 1.5 and 3.0 T: signal dependence on gadolinium and iodine concentrations--phantom study.

Gustav Andreisek1, Johannes M Froehlich, Juerg Hodler, Dominik Weishaupt, Verena Beutler, Christian W A Pfirrmann, Chris Boesch, Daniel Nanz.   

Abstract

PURPOSE: To prospectively quantify in vitro the influence of gadopentetate dimeglumine and ioversol on the magnetic resonance (MR) imaging signal observed with a variety of musculoskeletal pulse sequences to predict optimum gadolinium concentrations for direct MR arthrography at 1.5 and 3.0 T.
MATERIALS AND METHODS: In an in vitro study, T1 and T2 relaxation times of three dilution series of gadopentetate dimeglumine (concentration, 0-20.0 mmol gadolinium per liter) at ioversol concentrations with iodine concentration of 0, 236.4, and 1182 mmol iodine per liter (corresponding to 0, 30, and 150 mg of iodine per milliliter) were measured at 1.5 and 3.0 T. The relaxation rate dependence on concentrations of gadolinium and iodine was analytically modeled, and continuous profiles of signal versus gadolinium concentration were calculated for 10 pulse sequences used in current musculoskeletal imaging. After fitting to experimental discrete profiles, maximum signal-to-noise ratio (SNR), gadolinium concentration with maximum SNR, and range of gadolinium concentration with 90% of maximum SNR were derived. The overall influence of field strength and iodine concentration on these parameters was assessed by using t tests. The deviation of simulated from experimental signal-response profiles was assessed with the autocorrelation of the residuals.
RESULTS: The model reproduced relaxation rates of 0.37-38.24 sec(-1), with a mean error of 4.5%. Calculated SNR profiles matched the discrete experimental profiles, with autocorrelation of the residuals divided by the mean of less than 5.0. Admixture of ioversol consistently reduced T1 and T2, narrowed optimum gadolinium concentration ranges (P = .004-.006), and reduced maximum SNR (P < .001 to not significant). Optimum gadolinium concentration was 0.7-3.4 mmol/L at both field strengths. At 3.0 T, maximum SNR was up to 75% higher than at 1.5 T.
CONCLUSION: Admixture of ioversol to gadopentetate dimeglumine solutions results in a consistent additional relaxation enhancement, which can be analytically modeled to allow a near-quantitative a priori optimized match of contrast media concentrations and imaging protocol for a broad variety of pulse sequences. (c) RSNA, 2008.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18403628     DOI: 10.1148/radiol.2473071013

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  9 in total

1.  Fast MR arthrography using VIBE sequences to evaluate the rotator cuff.

Authors:  Jan E Vandevenne; Filip Vanhoenacker; Jestinah M Mahachie John; Geert Gelin; Paul M Parizel
Journal:  Skeletal Radiol       Date:  2009-03-18       Impact factor: 2.199

2.  Freehand direct arthrography of the shoulder using near real-time guidance in an open 1.0-T MRI scanner.

Authors:  Christian Wybranski; Ilya Adamchic; Friedrich-Wilhelm Röhl; Jens Ricke; Frank Fischbach; Katharina Fischbach
Journal:  Skeletal Radiol       Date:  2016-10-22       Impact factor: 2.199

3.  C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance.

Authors:  Roman Guggenberger; Erika J Ulbrich; Tobias J Dietrich; Rosemarie Scholz; Pascal Kaelin; Christoph Köhler; Thilo Elsässer; Thomas Le Corroller; Thomas Pfammatter; Hatem Alkadhi; Gustav Andreisek
Journal:  Eur Radiol       Date:  2016-05-24       Impact factor: 5.315

4.  Paralabral cysts in the hip joint: findings at MR arthrography.

Authors:  Olaf Magerkurth; Jon A Jacobson; Gandikota Girish; Monica Kalume Brigido; Asheesh Bedi; David Fessell
Journal:  Skeletal Radiol       Date:  2012-03-21       Impact factor: 2.199

Review 5.  The evolution of articular cartilage imaging and its impact on clinical practice.

Authors:  Carl S Winalski; Prabhakar Rajiah
Journal:  Skeletal Radiol       Date:  2011-08-17       Impact factor: 2.199

6.  Articular cartilage and labral lesions of the glenohumeral joint: diagnostic performance of 3D water-excitation true FISP MR arthrography.

Authors:  Tobias Johannes Dietrich; Marco Zanetti; Nadja Saupe; Christian W A Pfirrmann; Sandro F Fucentese; Juerg Hodler
Journal:  Skeletal Radiol       Date:  2009-12-17       Impact factor: 2.199

7.  Evaluation of Fetal Thyroid with 3D Gradient Echo T1-weighted MR Imaging.

Authors:  Shinya Fujii; Junichi Nagaishi; Naoko Mukuda; Sachi Kaneda; Chie Inoue; Takeru Fukunaga; Toshihide Ogawa
Journal:  Magn Reson Med Sci       Date:  2016-12-26       Impact factor: 2.471

Review 8.  [Direct MR Arthrography of the Hip: Diagnosis and Pitfalls of Acetabular Labral Lesions].

Authors:  Eun Sol Lim; Yong Kyun Kim; Hye Mi Park; Seung Jin Lee
Journal:  Taehan Yongsang Uihakhoe Chi       Date:  2021-06-16

9.  Short tau inversion recovery (STIR) after intravenous contrast agent administration obscures bone marrow edema-like signal on forefoot MRI.

Authors:  Tim Fischer; Yassir El Baz; Stephan Waelti; Simon Wildermuth; Sebastian Leschka; Sabine Güsewell; Tobias Johannes Dietrich
Journal:  Skeletal Radiol       Date:  2021-07-13       Impact factor: 2.199

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.