Literature DB >> 18403288

Application of tripolar concentric electrodes and prefeature selection algorithm for brain-computer interface.

Walter G Besio1, Hongbao Cao, Peng Zhou.   

Abstract

For persons with severe disabilities, a brain-computer interface (BCI) may be a viable means of communication. Lapalacian electroencephalogram (EEG) has been shown to improve classification in EEG recognition. In this work, the effectiveness of signals from tripolar concentric electrodes and disc electrodes were compared for use as a BCI. Two sets of left/right hand motor imagery EEG signals were acquired. An autoregressive (AR) model was developed for feature extraction with a Mahalanobis distance based linear classifier for classification. An exhaust selection algorithm was employed to analyze three factors before feature extraction. The factors analyzed were 1) length of data in each trial to be used, 2) start position of data, and 3) the order of the AR model. The results showed that tripolar concentric electrodes generated significantly higher classification accuracy than disc electrodes.

Entities:  

Mesh:

Year:  2008        PMID: 18403288     DOI: 10.1109/TNSRE.2007.916303

Source DB:  PubMed          Journal:  IEEE Trans Neural Syst Rehabil Eng        ISSN: 1534-4320            Impact factor:   3.802


  5 in total

1.  Improving the accuracy of Laplacian estimation with novel multipolar concentric ring electrodes.

Authors:  Oleksandr Makeyev; Quan Ding; Walter G Besio
Journal:  Measurement (Lond)       Date:  2016-02-01       Impact factor: 3.927

2.  The effects of concentric ring electrode electrical stimulation on rat skin.

Authors:  W Besio; V Sharma; J Spaulding
Journal:  Ann Biomed Eng       Date:  2010-01-20       Impact factor: 3.934

3.  Automatic seizure detection in rats using Laplacian EEG and verification with human seizure signals.

Authors:  Amal Feltane; G Faye Boudreaux-Bartels; Walter Besio
Journal:  Ann Biomed Eng       Date:  2012-10-17       Impact factor: 3.934

4.  Improving the Accuracy of Laplacian Estimation with Novel Variable Inter-Ring Distances Concentric Ring Electrodes.

Authors:  Oleksandr Makeyev; Walter G Besio
Journal:  Sensors (Basel)       Date:  2016-06-10       Impact factor: 3.576

5.  Solving the general inter-ring distances optimization problem for concentric ring electrodes to improve Laplacian estimation.

Authors:  Oleksandr Makeyev
Journal:  Biomed Eng Online       Date:  2018-08-30       Impact factor: 2.819

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.