Literature DB >> 18402900

A randomized comparison of triple-site versus dual-site ventricular stimulation in patients with congestive heart failure.

Christophe Leclercq1, Fredrik Gadler, Wolfgang Kranig, Sue Ellery, Daniel Gras, Arnaud Lazarus, Jacques Clémenty, Eric Boulogne, Jean-Claude Daubert.   

Abstract

OBJECTIVES: We compared the effects of triple-site versus dual-site biventricular stimulation in candidates for cardiac resynchronization therapy.
BACKGROUND: Conventional biventricular stimulation with a single right ventricular (RV) and a single left ventricular (LV) lead is associated with persistence of cardiac dyssynchrony in up to 30% of patients.
METHODS: This multicenter, single-blind, crossover study enrolled 40 patients (mean age 70 +/- 9 years) with moderate-to-severe heart failure despite optimal drug treatment, a mean LV ejection fraction of 26 +/- 11%, and permanent atrial fibrillation requiring cardiac pacing for slow ventricular rate. A cardiac resynchronization therapy device connected to 1 RV and 2 LV leads, inserted in 2 separate coronary sinus tributaries, was successfully implanted in 34 patients. After 3 months of biventricular stimulation, the patients were randomly assigned to stimulation for 3 months with either 1 RV and 2 LV leads (3-V) or to conventional stimulation with 1 RV and 1 LV lead (2-V), then crossed over for 3 months to the alternate configuration. The primary study end point was quality of ventricular resynchronization (Z ratio). Secondary end points included reverse LV remodeling, quality of life, distance covered during 6-min hall walk, and procedure-related morbidity and mortality. Data from the 6- and 9-month visits were combined to compare end points associated with 2-V versus 3-V.
RESULTS: Data eligible for protocol-defined analyses were available in 26 patients. No significant difference in Z ratio, quality of life, and 6-min hall walk was observed between 2-V and 3-V. However, a significantly higher LV ejection fraction (27 +/- 11% vs. 35 +/- 11%; p = 0.001) and smaller LV end-systolic volume (157 +/- 69 cm(3) vs. 134 +/- 75 cm(3); p = 0.02) and diameter (57 +/- 12 mm vs. 54 +/- 10 mm; p = 0.02) were observed with 3-V than with 2-V. There was a single minor procedure-related complication.
CONCLUSIONS: Cardiac resynchronization therapy with 1 RV and 2 LV leads was safe and associated with significantly more LV reverse remodeling than conventional biventricular stimulation.

Entities:  

Mesh:

Year:  2008        PMID: 18402900     DOI: 10.1016/j.jacc.2007.11.074

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  47 in total

Review 1.  Updates in Cardiac Resynchronization Therapy for Chronic Heart Failure: Review of Multisite Pacing.

Authors:  Antonios P Antoniadis; Ben Sieniewicz; Justin Gould; Bradley Porter; Jessica Webb; Simon Claridge; Jonathan M Behar; Christopher Aldo Rinaldi
Journal:  Curr Heart Fail Rep       Date:  2017-10

Review 2.  Left ventricular endocardial pacing and multisite pacing to improve CRT response.

Authors:  Sylvain Ploux; Zachary Whinnett; Pierre Bordachar
Journal:  J Cardiovasc Transl Res       Date:  2012-01-11       Impact factor: 4.132

Review 3.  Lead positioning strategies to enhance response to cardiac resynchronization therapy.

Authors:  Dan Blendea; Jagmeet P Singh
Journal:  Heart Fail Rev       Date:  2011-05       Impact factor: 4.214

Review 4.  How to improve outcomes with cardiac resynchronisation therapy: importance of lead positioning.

Authors:  Peter J Cowburn; Christophe Leclercq
Journal:  Heart Fail Rev       Date:  2012-11       Impact factor: 4.214

5.  Triple-site pacing: a new supported therapy approach for bridge to recovery with a left ventricular assist system in a patient with idiopathic dilated cardiomyopathy.

Authors:  Takashi Nishimura; Shunei Kyo
Journal:  J Artif Organs       Date:  2010-02-20       Impact factor: 1.731

6.  [Electrical therapy for heart failure. Perspectives for 2011].

Authors:  C W Israel
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2011-03

7.  [Technical innovations and limitation in cardiac electrotherapy].

Authors:  H-H Minden
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2011-03

8.  Rationale and design of a randomized trial to assess the safety and efficacy of MultiPoint Pacing (MPP) in cardiac resynchronization therapy: The MPP Trial.

Authors:  Gery Tomassoni; James Baker; Raffaele Corbisiero; Charles Love; David Martin; Robert Sheppard; Seth J Worley; Kwangdeok Lee; Imran Niazi
Journal:  Ann Noninvasive Electrocardiol       Date:  2017-05-18       Impact factor: 1.468

9.  Midterm 'super-response' to cardiac resynchronization therapy by biventricular pacing with fusion: insights from electro-anatomical mapping.

Authors:  Radu Vatasescu; Antonio Berruezo; Lluis Mont; David Tamborero; Marta Sitges; Etel Silva; Jose María Tolosana; Bárbara Vidal; David Andreu; Josep Brugada
Journal:  Europace       Date:  2009-10-31       Impact factor: 5.214

10.  Radial dyssynchrony assessed by cardiovascular magnetic resonance in relation to left ventricular function, myocardial scarring and QRS duration in patients with heart failure.

Authors:  Paul W X Foley; Kayvan Khadjooi; Joseph A Ward; Russell E A Smith; Berthold Stegemann; Michael P Frenneaux; Francisco Leyva
Journal:  J Cardiovasc Magn Reson       Date:  2009-11-24       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.