Literature DB >> 18396176

Positron emission tomography/computed tomography.

David W Townsend1.   

Abstract

Accurate anatomical localization of functional abnormalities obtained with the use of positron emission tomography (PET) is known to be problematic. Although tracers such as (18)F-fluorodeoxyglucose ((18)F-FDG) visualize certain normal anatomical structures, the spatial resolution is generally inadequate for accurate anatomic localization of pathology. Combining PET with a high-resolution anatomical imaging modality such as computed tomography (CT) can resolve the localization issue as long as the images from the two modalities are accurately coregistered. However, software-based registration techniques have difficulty accounting for differences in patient positioning and involuntary movement of internal organs, often necessitating labor-intensive nonlinear mapping that may not converge to a satisfactory result. Acquiring both CT and PET images in the same scanner obviates the need for software registration and routinely provides accurately aligned images of anatomy and function in a single scan. A CT scanner positioned in line with a PET scanner and with a common patient couch and operating console has provided a practical solution to anatomical and functional image registration. Axial translation of the couch between the 2 modalities enables both CT and PET data to be acquired during a single imaging session. In addition, the CT images can be used to generate essentially noiseless attenuation correction factors for the PET emission data. By minimizing patient movement between the CT and PET scans and accounting for the axial separation of the two modalities, accurately registered anatomical and functional images can be obtained. Since the introduction of the first PET/CT prototype more than 6 years ago, numerous patients with cancer have been scanned on commercial PET/CT devices worldwide. The commercial designs feature multidetector spiral CT and high-performance PET components. Experience has demonstrated an increased level of accuracy and confidence in the interpretation of the combined study as compared with studies acquired separately, particularly in distinguishing pathology from normal, physiologic tracer uptake and precisely localizing abnormal foci. Combined PET/CT scanners represent an important evolution in technology that has helped to bring molecular imaging to the forefront in cancer diagnosis, staging and therapy monitoring.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18396176     DOI: 10.1053/j.semnuclmed.2008.01.003

Source DB:  PubMed          Journal:  Semin Nucl Med        ISSN: 0001-2998            Impact factor:   4.446


  31 in total

1.  Age-related metabolic profiles in cognitively healthy elders: results from a voxel-based [18F]fluorodeoxyglucose-positron-emission tomography study with partial volume effects correction.

Authors:  P K Curiati; J H Tamashiro-Duran; F L S Duran; C A Buchpiguel; P Squarzoni; D C Romano; H Vallada; P R Menezes; M Scazufca; G F Busatto; T C T F Alves
Journal:  AJNR Am J Neuroradiol       Date:  2011-01-27       Impact factor: 3.825

Review 2.  Review of functional/anatomical imaging in oncology.

Authors:  Stephanie N Histed; Maria L Lindenberg; Esther Mena; Baris Turkbey; Peter L Choyke; Karen A Kurdziel
Journal:  Nucl Med Commun       Date:  2012-04       Impact factor: 1.690

3.  Fast and repetitive in-capillary production of [18F]FDG.

Authors:  Hans-Jürgen Wester; Bent Wilhelm Schoultz; Christina Hultsch; Gjermund Henriksen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-11-27       Impact factor: 9.236

4.  Navigating beyond the 6th dimension: a challenge in the era of multi-parametric molecular imaging.

Authors:  Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-07       Impact factor: 9.236

Review 5.  Innovations in Instrumentation for Positron Emission Tomography.

Authors:  Eric Berg; Simon R Cherry
Journal:  Semin Nucl Med       Date:  2018-03-12       Impact factor: 4.446

6.  (18)F-FDG PET/CT bone/bone marrow findings in Hodgkin's lymphoma may circumvent the use of bone marrow trephine biopsy at diagnosis staging.

Authors:  Gerard Moulin-Romsee; Elif Hindié; Xavier Cuenca; Pauline Brice; Didier Decaudin; Myriam Bénamor; Josette Brière; Marcela Anitei; Jean-Emmanuel Filmont; David Sibon; Eric de Kerviler; Jean-Luc Moretti
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-03-04       Impact factor: 9.236

Review 7.  Dynamic whole-body PET imaging: principles, potentials and applications.

Authors:  Arman Rahmim; Martin A Lodge; Nicolas A Karakatsanis; Vladimir Y Panin; Yun Zhou; Alan McMillan; Steve Cho; Habib Zaidi; Michael E Casey; Richard L Wahl
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-09-29       Impact factor: 9.236

8.  A U.S. Multicenter Study of Recorded Occupational Radiation Badge Doses in Nuclear Medicine.

Authors:  Daphnée Villoing; R Craig Yoder; Christopher Passmore; Marie-Odile Bernier; Cari M Kitahara
Journal:  Radiology       Date:  2018-02-01       Impact factor: 11.105

9.  A novel method for quantifying peripheral tissue amyloid load by using the radiolabeled amyloidophilic peptide, p5.

Authors:  Jonathan S Wall; Tina Richey; Sally Macy; Eric Heidel; Craig Wooliver; Stephen J Kennel
Journal:  Amyloid       Date:  2013-01-17       Impact factor: 7.141

Review 10.  Positron emission tomography-magnetic resonance imaging: technical review.

Authors:  Raymond F Muzic; Frank P DiFilippo
Journal:  Semin Roentgenol       Date:  2014-10-18       Impact factor: 0.800

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.