Literature DB >> 18395673

Left ventricular pacing site in cardiac resynchronization therapy: clinical follow-up and predictors of failed lateral implant.

Alfonso Macías1, Juan-José Gavira, Sara Castaño, Eduardo Alegría, Ignacio García-Bolao.   

Abstract

The effects of the left ventricular (LV) pacing site on the clinical results of resynchronization therapy (CRT) are not well characterized. The aim of this study was to define the effect of LV lead location on clinical response and LV remodelling, and to identify predictors of failure to implant the LV lead in a lateral location. One hundred and seventy two consecutive patients were evaluated at baseline and 6 months after CRT. In 128 patients, the LV lead was implanted in the lateral region (Group 1), while 44 received an anterior implant due to anatomical or electrical factors (Group 2). Group 1 was associated with a significantly better functional outcome assessed both by NYHA class (p<0.001) and by the six-minute-walk test (p=0.01) compared with group 2. LV ejection fraction and volumes, and inter- and intraventricular dyssynchrony only improved significantly (p<0.01) in group 1. The only independent predictor of a failed lateral implant was the presence of ischaemic cardiomyopathy (OR 3.29, 95% CI 2.2-13.7; p=0.02). In conclusion, a lateral lead location results in a better functional outcome and greater reverse LV remodelling compared with anterior locations. The presence of ischaemic cardiomyopathy is a risk factor for a failed lateral LV implant.

Entities:  

Mesh:

Year:  2008        PMID: 18395673     DOI: 10.1016/j.ejheart.2008.02.019

Source DB:  PubMed          Journal:  Eur J Heart Fail        ISSN: 1388-9842            Impact factor:   15.534


  4 in total

1.  Retaining of PTCA guide wire in the left ventricular lead and subsequent application of epicardial electrode when CRT-D implantation in a patient with severe heart failure and persistent left superior vena cava: a case report.

Authors:  Pei-Pei Hou; Yu-Hong Liu; Hai-Bo Qu; Jin Meng; Qiang Li; Zhi-Lin Miao
Journal:  Int J Clin Exp Med       Date:  2015-08-15

2.  [Technical innovations and limitation in cardiac electrotherapy].

Authors:  H-H Minden
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2011-03

3.  Analysis of lead placement optimization metrics in cardiac resynchronization therapy with computational modelling.

Authors:  Andrew Crozier; Bojan Blazevic; Pablo Lamata; Gernot Plank; Matthew Ginks; Simon Duckett; Manav Sohal; Anoop Shetty; Christopher A Rinaldi; Reza Razavi; Steven A Niederer; Nicolas P Smith
Journal:  Europace       Date:  2016-12       Impact factor: 5.214

4.  Left Ventricular Lead Placement Guided by Reduction in QRS Area.

Authors:  Mohammed Ali Ghossein; Francesco Zanon; Floor Salden; Antonius van Stipdonk; Lina Marcantoni; Elien Engels; Justin Luermans; Sjoerd Westra; Frits Prinzen; Kevin Vernooy
Journal:  J Clin Med       Date:  2021-12-17       Impact factor: 4.241

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.