| Literature DB >> 18394271 |
Michael D Green1, Henry Nettey, Robert A Wirtz.
Abstract
We developed a colorimetric and chromatographic assay for oseltamivir to assess the authenticity of Tamiflu (F. Hoffmann-La Roche Ltd., Basel, Switzerland) because of a growing concern about counterfeit oseltamivir. The colorimetric assay is quantitative and relies on an extractable colored ion-pair complex of oseltamivir with Congo red or bromochlorophenol blue. The reverse-phase chromatographic assay uses an alkaline mobile phase with UV detection. Both methods were evaluated for variability and selectivity and subsequently applied to batches of oseltamivir products acquired through the Internet. The Congo red test showed greater assay sensitivity, linearity, and accuracy. Colorimetric and chromatographic analysis showed all batches of oseltamivir product were within +/-15% of the stated amount of active ingredient.Entities:
Mesh:
Substances:
Year: 2008 PMID: 18394271 PMCID: PMC2570928 DOI: 10.3201/eid1404.061199
Source DB: PubMed Journal: Emerg Infect Dis ISSN: 1080-6040 Impact factor: 6.883
Figure 1Structure of oseltamivir.
Figure 2Spectra of Congo red and bromochlorophenol blue complexes with oseltamivir in ethyl acetate.
Accuracy and precision for the high-performance liquid chromatographic (HPLC) and colorimetric assays (n = 5)
| Nominal concentration, mg/mL | Accuracy, % | Precision, % | |||
|---|---|---|---|---|---|
| Interday | Intraday | Interday | Intraday | ||
| HPLC | |||||
| 0.6 | –10.8 | –10.3 | 9.0 | 7.9 | |
| 1.5 | –8.4 | 0.4 | 7.3 | 2.3 | |
| 2.4 | 5.0 | –0.7 | 7.3 | 5.7 | |
| 3.0 | 0.4 | 1.6 | 4.9 | 4.8 | |
| 3.6 | 0.7 | 4.4 | 4.1 | 3.6 | |
| 4.5 | –0.9 | –3.2 |
| 2.5 | 2.5 |
| Congo red colorimetric | |||||
| 1.5 | 2.0 | 2.2 | 12.5 | 2.3 | |
| 2.4 | 2.6 | –0.3 | 9.2 | 6.9 | |
| 3.0 | –5.5 | 1.0 | 6.5 | 5.4 | |
| 3.6 | 0.7 | 1.2 | 3.7 | 3.8 | |
| 4.5 | 1.0 | –0.1 |
| 2.6 | 1.3 |
| Bromochlorophenol blue colorimetric | |||||
| 6.0 | –5.3 | –19.4 | 18.6 | 12.4 | |
| 9.6 | 0.0 | 3.4 | 13.5 | 2.6 | |
| 12.0 | 2.7 | 10.4 | 6.1 | 5.9 | |
| 14.4 | 3.5 | 3.2 | 4.3 | 3.8 | |
| 18.0 | –2.9 | –5.4 | 4.9 | 3.0 | |
Figure 3Linearity of colorimetric assays.
Evaluation of oseltamivir products purchased over the Internet*
| Brand | HPLC | Congo red | Bromochlorophenol blue |
|---|---|---|---|
| A | 94 ± 1 | 95 ± 3 | 106 ± 4 |
| B | 87 ± 2 | 88 ± 3 | 97 ± 8 |
| C | 94 ± 4 | 93 ± 2 | 103 ± 3 |
| D | 96 ± 1 | 93 ± 5 | 107 ± 7 |
| E | 97 ± 3 | 89 ± 3 | 104 ± 5 |
| F | 95 ± 0 | 88 ± 2 | 101 ± 3 |
*HPLC, high-performance liquid chromatography. Values are the percentage of active ingredient found per capsule relative to that stated on the manufacturer’s package insert (average ±SD; n = 3 capsules).
Figure 4Chromatogram of oseltamivir from Tamiflu purchased over the Internet.