A wavelet-based method for improving signal-to-noise ratio and contrast in MR images.

M E Alexander1, R Baumgartner, A R Summers, C Windischberger, M Klarhoefer, E Moser, R L Somorjai.   

Abstract

Magnetic resonance (MR) images acquired with fast measurement often display poor signal-to-noise ratio (SNR) and contrast. With the advent of high temporal resolution imaging, there is a growing need to remove these noise artifacts. The noise in magnitude MR images is signal-dependent (Rician), whereas most de-noising algorithms assume additive Gaussian (white) noise. However, the Rician distribution only looks Gaussian at high SNR. Some recent work by Nowak employs a wavelet-based method for de-noising the square magnitude images, and explicitly takes into account the Rician nature of the noise distribution. In this article, we apply a wavelet de-noising algorithm directly to the complex image obtained as the Fourier transform of the raw k-space two-channel (real and imaginary) data. By retaining the complex image, we are able to de-noise not only magnitude images but also phase images. A multiscale (complex) wavelet-domain Wiener-type filter is derived. The algorithm preserves edges better when the Haar wavelet rather than smoother wavelets, such as those of Daubechies, are used. The algorithm was tested on a simulated image to which various levels of noise were added, on several EPI image sequences, each of different SNR, and on a pair of low SNR MR micro-images acquired using gradient echo and spin echo sequences. For the simulated data, the original image could be well recovered even for high values of noise (SNR approximately 0 dB), suggesting that the present algorithm may provide better recovery of the contrast than Nowak's method. The mean-square error, bias, and variance are computed for the simulated images. Over a range of amounts of added noise, the present method is shown to give smaller bias than when using a soft threshold, and smaller variance than a hard threshold; in general, it provides a better bias-variance balance than either hard or soft threshold methods. For the EPI (MR) images, contrast improvements of up to 8% (for SNR = 33 dB) were found. In general, the improvement in contrast was greater the lower the original SNR, for example, up to 50% contrast improvement for SNR of about 20 dB in micro-imaging. Applications of the algorithm to the segmentation of medical images, to micro-imaging and angiography (where the correct preservation of phase is important for flow encoding to be possible), as well as to de-noising time series of functional MR images, are discussed.

Mesh:

Year:  2000        PMID: 10722977     DOI: 10.1016/s0730-725x(99)00128-9

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  8 in total

1.  Denoising of arterial spin labeling data: wavelet-domain filtering compared with Gaussian smoothing.

Authors:  Adnan Bibic; Linda Knutsson; Freddy Ståhlberg; Ronnie Wirestam
Journal:  MAGMA       Date:  2010-04-28       Impact factor: 2.310

2.  K-space spatial low-pass filters can increase signal loss artifacts in Echo-Planar Imaging.

Authors:  E C Caparelli; D Tomasi
Journal:  Biomed Signal Process Control       Date:  2008-01       Impact factor: 3.880

3.  An optimized blockwise nonlocal means denoising filter for 3-D magnetic resonance images.

Authors:  P Coupe; P Yger; S Prima; P Hellier; C Kervrann; C Barillot
Journal:  IEEE Trans Med Imaging       Date:  2008-04       Impact factor: 10.048

4.  Nonlocal Means Denoising of Self-Gated and k-Space Sorted 4-Dimensional Magnetic Resonance Imaging Using Block-Matching and 3-Dimensional Filtering: Implications for Pancreatic Tumor Registration and Segmentation.

Authors:  Jun Jin; Elizabeth McKenzie; Zhaoyang Fan; Richard Tuli; Zixin Deng; Jianing Pang; Benedick Fraass; Debiao Li; Howard Sandler; Guang Yang; Ke Sheng; Shuiping Gou; Wensha Yang
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-02-06       Impact factor: 7.038

5.  Assessment and removal of additive noise in a complex optical coherence tomography signal based on Doppler variation analysis.

Authors:  Xuan Liu; Farzana Zaki; Dylan Renaud
Journal:  Appl Opt       Date:  2018-04-10       Impact factor: 1.980

6.  Improved DCT-based nonlocal means filter for MR images denoising.

Authors:  Jinrong Hu; Yifei Pu; Xi Wu; Yi Zhang; Jiliu Zhou
Journal:  Comput Math Methods Med       Date:  2012-03-07       Impact factor: 2.238

7.  Refined Simulation Method for Computer-Aided Process Planning Based on Digital Twin Technology.

Authors:  Yupeng Xin; Yiwen Chen; Wenhui Li; Xiuhong Li; Fengfeng Wu
Journal:  Micromachines (Basel)       Date:  2022-04-15       Impact factor: 2.891

8.  Denoising MR images using non-local means filter with combined patch and pixel similarity.

Authors:  Xinyuan Zhang; Guirong Hou; Jianhua Ma; Wei Yang; Bingquan Lin; Yikai Xu; Wufan Chen; Yanqiu Feng
Journal:  PLoS One       Date:  2014-06-16       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.