Randomized controlled trial of ionization and photoelectric smoke alarm functionality.

B A Mueller1, E A Sidman, H Alter, R Perkins, D C Grossman.   

Abstract

OBJECTIVE: To compare functionality, reasons for non-function, and nuisance alarm levels of two common types of smoke alarms after installation in low- to mid-level income households in King County, Washington.
METHODS: Randomized controlled trial of 761 households. An ionization or photoelectric smoke alarm was installed between June 1, 2000 and July 31, 2002. Main outcome measures were: percentage of study alarms that were working, observed reasons for non-functional status, and self-reported frequency of nuisance alarms at 9 and 15 months of follow-up.
RESULTS: At 9 months after installation, 20% of ionization, vs 5% of photoelectric alarms were non-functional, a difference that persisted at 15 months, with the most common reasons for both types being a disconnected or absent battery. The risk ratio for ionization, relative to photoelectric alarms, being non-functional or removed was 2.7 (95% CI 1.8 to 4.1) at 15 months of follow-up. These findings were not altered by educational level, or the presence of smokers, children <5 years, or adults > or =65 years.
CONCLUSIONS: Burn prevention efforts are geared towards increasing smoke alarm ownership and improving maintenance of functional status. Results suggest that the selective use of photoelectric alarms by fire injury prevention programs or consumers may provide longer-term protection in similar populations. Designing smoke alarms that minimize nuisance alarming may also result in longer term functionality.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18388226     DOI: 10.1136/ip.2007.016725

Source DB:  PubMed          Journal:  Inj Prev        ISSN: 1353-8047            Impact factor:   2.399


  3 in total

1.  Comprehensive smoke alarm coverage in lower economic status homes: alarm presence, functionality, and placement.

Authors:  Elanor A Sidman; David C Grossman; Beth A Mueller
Journal:  J Community Health       Date:  2011-08

2.  Smoke alarm giveaway and installation programs: an economic evaluation.

Authors:  Ying Liu; Karin A Mack; Shane T Diekman
Journal:  Am J Prev Med       Date:  2012-10       Impact factor: 5.043

3.  Increasing smoke alarm operability through theory-based health education: a randomised trial.

Authors:  Ted R Miller; Gwen Bergen; Michael F Ballesteros; Soma Bhattacharya; Andrea Carlson Gielen; Monique S Sheppard
Journal:  J Epidemiol Community Health       Date:  2014-08-27       Impact factor: 3.710

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.